Turning The Stove Off; Power Failure; Servicing; User Servicing - Stanley Tara Mk3 Installation And Operation Instructions Manual

Oil stove
Table of Contents

Advertisement

glass may only become evident when the flame is
viewed through the glass.
In certain circumstances it may be necessary to
prime the flue see previous sections on "flue
draught" and" priming the flue".
Turn the oil control valve to setting 2, press and
hold the ignition button for a duration of 90 sec-
onds. Within the 90 seconds a small flame should
appear in the base of the burn pot where the
kerosene enters. After the 90 seconds if there is
no flame present turn the control valve to the off
position, leave the stove for 10 minutes to evac-
uate vapours within the combustion chamber and
attempt the lighting process only once more.
When the flame is established for 10 minutes on
setting no 2 the control lever can be adjusted to
setting no 4 . The flame should be allowed to sta-
bilise at setting no 4 for another 10 minutes prior
to adjusting the control to setting No.6 ( Max).
When the control setting is adjusted a period of
stabilisation is required for the flue draught, ad-
justing the control too fast can lead to a situation
where the fuel proportion in relation to air is much
too high leading to poor combustion and a sooty
flame.

TURNING THE STOVE OFF

When the control knob is turned to 0 from any posi-
tion, the oil feed to the stove is closed and the stove
goes out.
NOTE:
DO NOT RELIGHT THE STOVE WHEN IT
IS HOT.

POWER FAILURE

A break in the electrical supply while the stove is light-
ing will have no effect on the stove. However an elec-
trical supply is necessary for lighting the stove.

SERVICING

NOTE:
ALL WORK SHOULD BE CARRIED OUT
WHEN THE STOVE IS COOL AND THE OIL
SUPPLY IS TURNED OFF.

USER SERVICING

Every two or three months (depending on use):
1. Remove the flame spreader and the catalyser.
Clean out all carbon deposits in the burner and
on the catalyser (See Fig. 22).
2. Clean the internals of the burner compartment
using a damp cloth.
3. Clean any marks or stains on the viewing glass.
4. Replace the flame spreader and catalyser.
(Flame spreader should be fitted with concave
side facing down).
Fig.22
Fig.21

ANNUAL SERVICING

Note: Annual servicing of the stove should only be
undertaken by a fully trained and competent person.
1. Isolate the electrical supply to the stove and
ensure that the control valve is at setting O.
2. Clean the inlet pipe as follows:
A. Remove the blanking nut and find a suitable
rod/screwdriver which can be inserted into the
feed pipe. See Fig.23.
B. Rotate the rod through 360
in and out, take care not to push it in too far
so that it hits the ignition probe.
C. Refit the blanking nut taking care to replace
the sealing washers.
16
o
whilst pushing it

Advertisement

Table of Contents
loading

Table of Contents