Page 1
Operation, Installation & Servicing Instructions IMPORTANT Please read these instructions carefully and keep them in a safe place. They will be needed when servicing this appliance. STANDARD FLUE MEDIUM MAEVE STOVE STANDARD FLUE MEDIUM MAEVE STOVE WITHOUT GRILL WITH GRILL STOVES REQUIRED TO HAVE THE GRILL OPTION MUST BE ORDERED AS THEY ARE FACTORY FITTED.
INSTRUCTIONS FOR USE GENERAL CLEANING THE STOVE Installation and servicing must only be Remove the ceramic coals and place on a carried out by a competent person. dry, clean surface. Remove the front coal In all correspondence, please quote the ceramic, please handle with care.
THE FLAME FAILURE DEVICE This is a safety feature incorporated in all WATERFORD fires which automatically switches off the gas supply if the pilot light goes out and fails to heat the thermo- couple. 'RUNNING IN' The surface coating on the coals used in your WATERFORD fire will "burn off"...
Page 5
INSTRUCTIONS FOR INSTALLATION & SERVICING NOTE: IF IT IS INTENDED TO FIT THE IMPORTANT: ENSURE THAT THE APPLI STOVE INTO AN EXISTING BRICK ANCE IS CORRECTLY ADJUSTED FOR THE GAS TYPE AND CATEGORY CHIMNEY, A 127mm LINER MUST BE USED. APPLICABLE IN THE COUNTRY OF USE.
Page 6
Ensure that the gas supply is capable of gas controls. Connect the gas supply to delivering the required amount of gas, and the 8mm-compression elbow at the right is in accordance with the rules in force. hand rear corner of the stove, see Fig.10. Soft copper tubing and soft soldered joints Check the pull of the flue system by apply- can be used but must not be closer than...
Page 7
flame baffle, and a further two large coals device, remove the door and place to one on the flame baffle, one at each end, see side, carefully remove the ceramic fuelbed Fig. 14. components. Place five small coals along the rear of the 10.2 Undo the pilot compression nut, remove flame baffle, resting against the rear ledge,...
Page 8
GAS FILTER If it has been necessary to remove the The gas filter is located just inside the inlet stove, ensure that all disturbed gas joints boss of the control valve, to replace the fil- are leak tested when reinstalled, and ter, proceed as follows: repeat the flue clearance test as detailed in section 9.
Page 11
DIAGRAMS Fig.7 Medium 1007 470 Fig.8 A = 225mm B = 150mm Fig.9 A = 50mm B = 150mm...
3. A soundness test must be conducted to check all joints for gas tightness. Manufactured by Waterford Stanley Ltd., Unit 210, IDA Industrial Estate, Cork Road, Waterford, Ireland. Tel: (051) 302300 Fax (051) 302315...