MAEVE BALANCED FLUE STOVE RANGE Operation, Installation & Servicing Instructions IMPORTANT Please read these instructions carefully and keep them in a safe place. They will be needed when servicing this appliance. BALANCED FLUE MEDIUM MAEVE BALANCED FLUE MEDIUM MAEVE STOVE WITH GRILL STOVE WITHOUT GRILL STOVES REQUIRED TO HAVE THE GRILL OPTION MUST BE ORDERED AS THEY ARE FACTORY FITTED.
INSTRUCTIONS FOR USE 1. GENERAL NOTE: THE YELLOW FLAMES WILL Installation and servicing must only be car- APPEAR WHEN THE FIRE HAS GAINED ried out by a competent person. SUFFICIENT HEAT – TYPICALLY 10 TO In all correspondence, please quote the 20 MINUTES.
The half round end of log D should face For stubborn deposits a soap impregnated forwards showing a dark burnt effect, see pad can be carefully used on the vitreous Fig.21. enamel. Place log E across from the rear log A to Use only products recommended by the log C on the right hand side.
Page 5
INSTRUCTIONS FOR INSTALLATION AND SERVICING IMPORTANT: ENSURE THAT THE or above a flat roof to which people have APPLIANCE IS CORRECTLY ADJUSTED access), is to be fitted with the guard sup- FOR THE GAS TYPE AND CATEGORY plied, see Fig 6. (supplied with rear exit) APPLICABLE IN THE COUNTRY OF 11.3 Rear exit flue will accommodate walls...
Page 6
A 152mm (6") diameter hole is required to TIMBER FRAMED BUILDINGS install the flue. This can be achieved by either: 14.5 It will be necessary to provide additional a) Core drill. clearance when the fire passes through a b) Hammer and chisel. wall containing any combustible materials It is advisable to drill small holes around so as to prevent a fire hazard.
ing the flue slides smoothly through the 15.10 The appliance is factory set for rear exit wall. Alternatively, place the flue terminal therefore for top exit the spigots and blank- in the wall, place the stove on the hearth ing plates must be reversed, see Fig 14. and connect the flue to the elbow.
Page 8
19. MAIN BURNER 16.4 Place log D across from the rear log A to 19.1 Turn the gas supply off at the isolation log B on the left hand side. There are device, remove the door and place to one cutouts in both logs for location.
Page 9
20.5 To remove the electrode, disconnect the 22.2 Replace with a new filter and push into ignition lead and undo the retaining nut. position ensuring that it sits on the shoul- The electrode can now be removed, note der, replace the retaining ring and push into the orientation of the electrode terminal position.
CHANGING BETWEEN GAS TYPES The relevant parts can be ordered from In order to change between gas types, it the parts list,always quote the appliance type and serial number when ordering will be necessary to change the following spare parts. items: Pilot Injector NOTE: THE CONTROL VALVE IS FAC-...
Page 13
Fig.5 Dimension Terminal Position Minimum Distance (mm) Directly below an openable window or other opening e.g. air brick Below gutters, soil pipes or drain pipes Below eaves Below balconies or car port roofs From vertical drain pipes and soil pipes From internal or external corners Above ground, roof or balcony level From a surface facing a terminal...
Page 14
Fig.7 1007 mm 470 mm Fig.8 A = 225mm B = 150mm Fig.9 A = 50mm B = 150mm Fig.10 A = 152mm B = 510mm...
3. A soundness test must be conducted to check all joints for gas tightness. Manufactured by Waterford Stanley Ltd., Unit 210, IDA Industrial Estate, Cork Road, Waterford, Ireland. Tel: (051) 302300 Fax (051) 302315...