Volt-Ampere Curves − 60 Hz Operation - Miller Electric Big Blue 400 PX Owner's Manual

Engine driven welding generator
Table of Contents

Advertisement

4-5. Volt-Ampere Curves − 60 Hz Operation
A. Stick Mode
100
90
80
70
60
50
40
30
MIN
20
10
0
0
100
B. MIG Mode
100
80
60
MAX
40
20
MIN
0
0
C. TIG Mode
100
80
60
40
20
MIN
0
0
2 00
DC AM PERES
100
200
DC AM PERES
100
200
DC AMPERES
MAX
300
300
400
300
400
300
MAX
300
400
500
The volt-ampere curves show the
minimum and maximum voltage
and amperage output capabilities of
the welding generator. Curves of all
other settings fall between the
curves shown.
500
500
217 517 / 217 516 / 217 518
OM-223 037 Page 17