5-7. Connecting To Weld Output Terminals
!
Stop engine.
1
Work (−) Weld Output Terminal
2
CV (Wire) Weld Output Terminal
3
CC (Stick/TIG) Weld Output
Terminal
Making Connections
4
Weld Output Terminal
5
Supplied Weld Output Terminal
Nut
6
Weld Cable Terminal
7
Copper Bar
Remove supplied nut from weld out-
put terminal. Slide weld cable terminal
onto weld output terminal and secure
with nut so that weld cable terminal is
tight against copper bar. Do not
place anything between weld cable
terminal and copper bar. Make sure
that the surfaces of the weld cable
terminal and copper bar are clean.
7
4
5
6
Correct Installation
Stick and TIG Welding
For Stick and TIG welding Direct Cur-
rent Electrode Positive (DCEP), con-
nect electrode holder cable to CC
(Stick/TIG) terminal on right and work
cable to Negative (−) terminal on left.
For Direct Current Electrode Nega-
tive
(DCEN),
connections.
Use Process/Contactor switch to se-
lect type of weld output (see Section
6-3).
1
Do not place
anything between
weld cable terminal
and copper bar.
Tools Needed:
3/4 in
MIG and FCAW Welding
For MIG and FCAW welding Direct
Current Electrode Positive (DCEP,
connect wire feeder cable to CV
(Wire) terminal on right and work
cable to Work/Negative (−) terminal
on left.
switch to select type of weld output
reverse
cable
(see Section 6-3).
For Direct Current Electrode Nega-
tive
connections.
Incorrect Installation
Use Process/Contactor
(DCEN),
reverse
cable
2
3
Ref. 804 068 / 803 778 / 222 875-A