DHW control settings
Hysteresis/Hysteresis booster heater
Note
The value selected for "Hysteresis"
should be higher than the expected
temperature drop due to heat losses
in a single night (approx. 5 K).
A lower value for "Hyst. booster hea-
ter" increases the proportion of elec-
trical DHW heating, i.e. the system
efficiency drops.
Access
"Device settings"
"Programming"

Start optimisation DHW

Parameter
6009

Stop optimisation DHW

Parameter
600A
DHW auxiliary function
Parameter
600B
148
(cont.)
"DHW"
y to"Hysteresis"
or
y to"Hyst. booster heater"
5 or %
Hysteresis
Standard setting
Setting range
Hysteresis booster heater
Standard setting
Setting range
Operating instructions
Operating instructions
Operating instructions
7.0 K
1.0 to 10.0 K
10.0 K
2.0 to 30.0 K