Start Optimisation For Cylinder Heating - Viessmann vitocal 300-g Operating Instructions Manual

Compact heat pump with electric drive, type bw/bwc and ww/wwc
Table of Contents

Advertisement

Set temperature 2 (DHW)
Note
■ The "Set temp. 2" for DHW cannot be
set higher than the maximum DHW
cylinder temperature.
■ The second set temperature cannot be
set higher than the max. DHW cylinder
temperature.
■ The maximum DHW cylinder temper-
ature can only be changed by your
heating contractor.
■ Temperatures above 60 °C can only
be achieved with an instantaneous
heating water heater in the heating
flow or an electric immersion heater
EHE in the DHW cylinder.
DHW
Set DHW temp.
Switching times DHW
DHW with e heating
Start optimisation
Stop optimisation
Pasteurisation
Set temp. 2
-1.0

Start optimisation for cylinder heating

The start optimisation ensures that DHW is available at the required temperature at
the beginning of standard mode.
Note
This function is only enabled if switching
times have been set for the DHW cylin-
der (see page 30).
(cont.)
Press the following keys:
1. "Device settings"
2. "Programming"
3. "DHW"
4. y/x for "Set temp. 2"
5. 1/! for the selected value
6. "BACK"
[°C]
:
50.0
:
T
Yes
:
:
No
:
No
:
Yes
:
60.0
Back
DHW
Set DHW temp.
Switching times DHW
DHW with e heating
Start optimisation
Stop optimisation
Pasteurisation
Set temp. 2
Selecting DHW heating
to confirm and exit the
menu
[1/0]
:
50.0
:
T
:
Yes
:
No
:
No
:
Yes
:
60.0
YES
Back
35