DHW control settings
Cylinder temperature DHW
Parameter
6000
DHW switching times
Parameter
6001
Min. temperature
Parameter
6005
The minimum temperature prevents
the DHW temperature inside the DHW
cylinder from falling too low (frost pro-
tection).
When the actual temperature falls
below the min. temperature, the DHW
cylinder is heated up to that value
plus hysteresis. This is independent
of the selected operating program.
Max. temperature
Parameter
6006
Renewed heating will be prevented after this max. temperature has been
reached inside the DHW cylinder, until the temperature has dropped by at least
5 K.
146
Operating instructions
Operating instructions
If 2 cylinder temperature sensors are
fitted, only the top sensor will be used
to capture the temperature.
Access
"Device settings"
"Programming"
"DHW"
y to"Min. temp."
1 or !
Standard setting
Setting range
10 °C
5 to 60 °C