3-7. Rear Panel Receptacles And Supplementary Protectors

4
2
3
OM-210 540 Page 14
5
6
1
115 V 10 A AC Receptacle RC2
1
Receptacle
single-phase power. Maximum output
from RC2 is limited by supplementary
protector CB1 to 10 amps.
2
Supplementary Protector CB1
3
Supplementary Protector CB2
CB1 protects 115 volt receptacle RC2
from overload. If CB1 opens, RC2 does
not work.
CB2 protects the wirefeed motor from
overload. If CB2 opens, the wirefeeder
does not work.
.
Press button to reset breaker. If
breaker continue to open, contact a
Factory Authorized Service Agent.
4
Wirefeed/Gas Receptacle RC8
Use receptacle to connect gas and
motor control cable to power source
(see Sections 3-6 and 8 for additional
information).
5
Peripheral Receptacle RC25
Receptacle provides connection to
touch sensor, water flow switch, jog +/−,
and I/O relay contacts circuitry (see
Section 3-10).
6
Robot Interface Receptacle RC72
Use receptacle to connect robot
input/output cable (see Sections 3-6
and 8 for additional information).
supplies
60
Hz
Ref. 803 245-B

Hide quick links:

Advertisement

Table of Contents
loading