Summary of Contents for Miller Electric Invision 456MP
Page 1
Visit our website at www.MillerWelds.com Invision 456MP (230/460 And 575 Volt Models) OM-193 267R 2007−10 Processes Processes MIG (GMAW) and Pulsed MIG (GMAW-P) Welding Flux Cored (FCAW) Welding Stick (SMAW) Welding Description File: MIG (GMAW)
Page 2
ISO 9001:2000 Quality System Standard. particular model are also provided. Miller Electric manufactures a full line of welders and welding related equipment. For information on other quality Miller products, contact your local Miller distributor to receive the latest full line catalog or individual specification sheets.
DC constant voltage (wire) welder, 2) a DC manual (stick) welder, or 3) an AC welder with reduced open-circuit volt- age. In most situations, use of a DC, constant voltage wire welder is recommended. And, do not work alone! D Disconnect input power or stop engine before installing or servicing this equipment.
Page 6
OM-193 267 Page 2 D Do not use welder to thaw frozen pipes. D Remove stick electrode from holder or cut off welding wire at contact tip when not in use.
1-3. Additional Symbols For Installation, Operation, And Maintenance FIRE OR EXPLOSION hazard. D Do not install or place unit on, over, or near combustible surfaces. D Do not install unit near flammables. D Do not overload building wiring − be sure power supply system is properly sized, rated, and protected to handle this unit.
1-4. California Proposition 65 Warnings Welding or cutting equipment produces fumes or gases which contain chemicals known to the State of California to cause birth defects and, in some cases, cancer. (California Health & Safety Code Section 25249.5 et seq.) Battery posts, terminals and related accessories contain lead and lead compounds, chemicals known to the State of California to cause cancer and birth defects or other...
SECTION 2 − CONSIGNES DE SÉCURITÉ − LIRE AVANT UTILISATION Se protéger et protéger les autres contre le risque de blessure — lire et respecter ces consignes. 2-1. Symboles utilisés DANGER! − Indique une situation dangereuse qui si on l’évite pas peut donner la mort ou des blessures graves. Les dangers possibles sont montrés par les symboles joints ou sont expliqués dans le texte.
Page 10
Il reste une TENSION DC NON NÉGLIGEABLE dans les sources de soudage onduleur quand on a coupé l’alimentation. D Arrêter les convertisseurs, débrancher le courant électrique et décharger les condensateurs d’alimentation selon les instructions indiquées dans la partie Entretien avant de toucher les pièces. DES PIÈCES CHAUDES peuvent provoquer des brûlures graves.
ACCUMULATIONS risquent de provoquer des blessures ou même la mort. D Fermer l’alimentation du gaz protecteur en cas de non-utilisation. D Veiller toujours à bien aérer les espaces confi- nés ou se servir d’un respirateur d’adduction d’air homologué. LES CHAMPS MAGNETIQUES peuv- ent affecter des implants médicaux.
LES FILS DE SOUDAGE peuvent provoquer des blessures. D Ne pas appuyer sur la gâchette avant d’en avoir reçu l’instruction. D Ne pas diriger le pistolet vers soi, d’autres per- sonnes ou toute pièce mécanique en enga- geant le fil de soudage. DES ORGANES MOBILES peuvent provoquer des blessures.
2-5. Principales normes de sécurité Safety in Welding, Cutting, and Allied Processes, ANSI Standard Z49.1, de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www.global.ihs.com). Recommended Safe Practices for the Preparation for Welding and Cut- ting of Containers and Piping, American Welding Society Standard AWS F4.1 de Global Engineering Documents (téléphone : 1-877-413-5184, site Internet : www.global.ihs.com).
3-3. Volt-Ampere Curves 3-4. Dimensions and Weight Hole Layout Dimensions 14-21/64 in (363.9 mm) 20-3/4 in (527.1 mm) 23-27/64 in (594.9 mm) 24-31/32 in (634.2 mm) 12-3/8 in (314.3 mm) 9/32 in (7.1 mm) Dia. Weight 118 lb (53.5 kg) OM-193 267 Page 12 A.
3-5. Selecting a Location Movement Location 18 in (460 mm) Tipping 18 in (460 mm) Do not move or operate unit where it could tip. Lifting Forks Use lifting forks to move unit. Extend forks beyond opposite side of unit. Lifting Handles Use handles to lift unit.
3-6. Weld Output Terminals and Selecting Cable Sizes ARC WELDING can cause Electromagnetic Interference. To reduce possible interference, keep weld cables as short as possible, close together, and down low, such as on the floor. Locate welding operation 100 meters from any sensitive electronic equipment. Be sure this welding machine is installed and grounded according to this manual.
3-7. Connecting Weld Output Cables Tools Needed: 3/4 in (19 mm) Turn off power before connecting to weld output terminals. Failure to properly connect weld cables may cause excessive heat and start a fire, or damage your ma- chine. 3-8. Remote 14 Receptacle Information C L N *The remaining sockets are not used.
3-9. 115 Volts AC Duplex Receptacle and Circuit Breakers 3-10. Electrical Service Guide NOTICE − INCORRECT INPUT POWER can damage this welding power source. This welding power source requires a CONTINUOUS supply of input power at rated frequency(+10%) and voltage (+10%). Phase to ground voltage shall not exceed +10% of rated input voltage. Do not use a genera- tor with automatic idle device (that idles engine when no load is sensed) to supply input power to this welding power source.
3-11. Selecting Input Voltage Be sure to reinstall all four screws securing relinking board in place. Tools Needed: 5/16 in Turn Off welding power source, disconnect input power, and check voltage on input capacitors accord- ing to Section 6-3 before proceeding.
3-12. Connecting Input Power L1 L2 L3 Connections For Standard Model Connections For Models With Optional Ground Current Sensor OM-193 267 Page 18 = GND/PE Always connect grounding conductor first. Tools Needed: Turn Off welding power source, and check voltage on input capacitors accord- ing to Section 6-3 before proceeding.
SECTION 4 − OPERATION 4-1. Front Panel Controls Power Switch The fan motor is thermostatically controlled and only runs when cooling is needed. Voltmeter (see Section 4-2) Ammeter/Trim Indicator (see Section 4-2) Ammeter Light Lights when display beneath is indicating amperage.
4-2. Meter Functions The meters display the actual weld output values for approximately three seconds after the arc is broken. Mode Preset Volts Pulsed Stick− Contactor Remote Stick− Contactor ON Actual Volts (OCV) Manual Pulse The Stick mode provides the Adaptive Hot Start feature, which automatically increases the output amperage at the start of a weld should the start require it.
4-3. Example Displays Values shown are hypothetical. The “A” (Amperage) and “Trim” lights illuminate as shown. Amperage preset display for Stick welding mode. Voltage preset display for MIG welding mode. Display while welding. Preset trim display for Pulse welding mode. Preset pulses per second (PPS) display for Manual Pulse welding mode.
4-4. Synergic Controls and Overview Example To select Program 7, set to Non Adaptive, and set Arc Length to 36, proceed as follows: Select top line by pressing > P r g Select push button until > is on top line. Press Increment button until Program 7 ap- A d a p t i v e pears.
4-7. Choosing Pulse Programs and Setting Parameters Choosing Pulse Program: Pulse programs are pre-written and cannot be changed by the user. See Section 5 for program parameters and recommended gas mixtures. Choose program depending on the type and size of wire, and type of shielding gas used.
SECTION 5 − PROGRAMS Section 5-1 provides basic information on each of the fifteen programs in the unit’s memory. See Section 5-2 for more detailed information on each of the programs. Synergic Information: The manufacturer makes no warranties, express or implied, that welds made using the synergic parameters of this equip- ment will meet the requirements of the application.
5-2. Programs Program 1 −− .035 ER70S−3 Mild Steel −− Recommended Gases: Argon/CO Trim Peak Amp Program 2 −− .045 ER70S−3 Mild Steel −− Recommended Gases: Argon/CO Trim Peak Amp OM-193 267 Page 28 Gases: Argon/CO mixes up to 10% CO Argon/O mixes up to 5% O Background Amp...
Page 33
Program 3 −− .052 ER70S−3 Mild Steel −− Recommended Gases: Argon/CO Gases: Argon/CO Trim Peak Amp Program 4 −− .062 ER70S−3 Mild Steel −− Recommended Gases: Argon/CO Gases: Argon/CO Trim Peak Amp Program 5 −− .035 309L Stainless Steel −− Recommended Gases: 98 Argon/2 CO Alternative Gases: Argon/CO Trim Peak Amp...
Page 34
Program 6 −− .045 309L Stainless Steel −− Recommended Gases: 98 Argon/2 CO Alternative Gases: Argon/CO Trim Peak Amp Trim Peak Amp Trim Peak Amp OM-193 267 Page 30 mixes up to 10% CO Argon/O mixes up to 5% O Background Amp Freq.
Page 35
Program 9 −− 1/16 .062 Aluminum 4043 −− Argon Trim Peak Amp Program 10 −− .035 Aluminum 5356 −− Argon Trim Peak Amp Program 11 −− .047 Aluminum 5356 −− Argon Trim Peak Amp Background Amp Freq. Background Amp Freq. Background Amp Freq.
Page 36
Trim Peak Amp Program 13 −− .035 Nickel −− 75 Argon/25 Helium Trim Peak Amp Program 14 −− .045 Nickel −− 75 Argon/25 Helium Trim Peak Amp OM-193 267 Page 32 Program 12 −− .062 Aluminum 5356 −− Argon Background Amp Freq.
Page 37
Program 15 −− .035 Silicon Bronze −− Argon Trim Peak Amp Program 16 −− .045 Metal Core −− Recommended Gases: Argon/CO Gases: Argon/CO Trim Peak Amp Program 17 −− .052 Metal Core −− Recommended Gases: Argon/CO Gases: Argon/CO Trim Peak Amp Background Amp Freq.
Page 38
Program 18 −− .062 Metal Core −− Recommended Gases: Argon/CO Trim Peak Amp OM-193 267 Page 34 Gases: Argon/CO mixes up to 20% CO Background Amp Freq. Pulse Width Starting Amps 2.10 2.30 2.40 2.50 2.60 2.75 2.90 3.05 3.20 3.35 3.50...
SECTION 6 − MAINTENANCE AND TROUBLESHOOTING 6-1. Routine Maintenance 3 Months Replace damaged or unreadable label. Repair or replace cracked cables and cords. Clean and tighten weld terminals. 6-2. Blowing Out Inside of Unit Disconnect power before maintaining. Repair or replace cracked cables.
6-3. Removing Right Side Panel and Measuring Input Capacitor Voltage in 230/460 Volt Models Significant DC voltage can remain on capacitors af- ter unit is Off. Always check the voltage as shown to be sure the input capacitors have discharged be- fore working on unit.
6-4. Removing Right Side Panel and Measuring Input Capacitor Voltage in 575 Volt Models Significant DC voltage can remain on capacitors af- ter unit is Off. Always check the voltage as shown to be sure the input capacitors have discharged be- fore working on unit.
6-5. Voltmeter/Ammeter Help Displays HE.L P−1 HE.L P−2 HE.L P−3 HE.L P−4 HE.L P−5 HE.L P−6 HE.L P−7 HE.L P−8 OM-193 267 Page 38 All directions are in reference to the front of the unit. All circuitry referred to is located inside the unit.
Page 51
Warranty Questions? LIMITED WARRANTY − Subject to the terms and conditions Call below, Miller Electric Mfg. Co., Appleton, Wisconsin, warrants to 1-800-4-A-MILLER its original retail purchaser that new Miller equipment sold after the effective date of this limited warranty is free of defects in for your local material and workmanship at the time it is shipped by Miller.
File a claim for loss or damage during shipment. For assistance in filing or settling claims, contact your distributor and/or equipment manufacturer’s Transportation Department. 2007 Miller Electric Mfg. Co. 2007−01 Miller Electric Mfg. Co. An Illinois Tool Works Company 1635 West Spencer Street Appleton, WI 54914 USA International Headquarters−USA...