Vent Free Features; Fresh Air Requirements - Vermont Castings 0003380 Operating Manual

Table of Contents

Advertisement

Vent Free Features

The Radiance Vent Free stove, is an unvented gas
heating appliance tested and listed to the ANSI stan-
dard Z21.11.2 Latest Edition. This appliance is specifi-
cally configured to burn either Natural Gas or Propane
fuel, as indicated on the metal rating plate attached to
the rear shroud. The Radiance Vent Free is not fuel
convertible.
The stove is shipped fully assembled with the exception
of the log set. The log set is assembled during installa-
tion.
The stove is equipped with an SIT control valve that
allows thermostatic control, on/off switch or a remote
switch (not supplied).
The stove model incorporates variable regulators that
allow you to adjust burner heat output between HIGH,
(35,000 Btu), and LOW, (26,000 Btu). See the Opera-
tion Section for details.
A push button Piezo ignitor is used to light the stand-
ing pilot. The pilot incorporates an Oxygen Depletion
System (ODS/pilot) which will shut off gas flow to the
burner in the event that sufficient fresh air becomes
unavailable for continued safe operation.
Fresh Air Requirements for Combustion
and Ventilation
WARNING
This heater must have fresh air for proper opera-
tion. If not, poor fuel combustion could result. Read
the following instructions to insure proper fresh
air for this and other fuel-burning appliances in
your home.
30005056
Radiance® Vent-Free Gas Heater
Modern construction standards have resulted in homes
that are highly energy-efficient and that allow little heat
loss. Your home needs to breathe, however, and all
fuel-burning appliances within it require fresh air in
order to function properly and safely. Exhaust fans,
clothes dryers, fireplaces, and other fuel burning appli-
ances all use the air inside the building. If the available
fresh air is insufficient to meet the demands of these
appliances, problems can result.
The Radiance Unvented heater has specific fresh air
requirements. You must determine that these fresh
air requirements will be met within the space where
the appliance will be installed. The following informa-
tion will help you insure that adequate fresh air is avail-
able for the heater to function properly.
If the area in which the heater may be
operated does not meet the required volume
for indoor combustion air, combustion and
ventilation air shall be provided by one
of the methods described in the National
Fuel Gas Code, ANSI Z223.1/NFPA 54, the
International Fuel Gas Code or applicable
local codes.