6.9.2 Wet scrubbing (with vacuuming)
Initial use
Shutting down
Switch the programme selector switch (S2) to position "wet scrubbing with vacuuming"
Suction turbine (M2) active
Speed reset suction turbine speed (M2) active, if set to "1" in the setup menu (option only)
Detergents active, if set to "1" in the setup menu
FACT active if set to "1" in the setup menu
Red LED "Fault" is glowing continuous-
ly
After approx. 10 seconds of overload,
the following will be shut off
Brush motor
–
Solenoid valve water
–
Dosing pump detergent (optional)
–
Red LED "Fault" is blinking
Switch the programme selector switch
(S2) to position "OFF and perform star-
tup
LED "Battery" (green)
LED "Battery" (green)
Brush motor (M1) ready
Deadman switch (S3)
actuated?
Yes
Brush motor (M1) active
- Check the solenoid
valve.
Yes Brush motor overload?
No
(Option) detergent
switch (S5) on?
Yes
Dosing pump (optional)
on
English 5.906-269.0 Rev. 00 (03/11)
No
No
59