Kärcher BR 45/40 Service Manual page 73

Table of Contents

Advertisement

Parameter
Factory
setting
Power B / W:
60A
60 A
Power turb:
30A
30A
Contrast
22
LCD: 22
min:step:max
Remarks
30 A:1 A:60 A
Max. regular power of the brush.
In case of overload, the power is limited
to the set up value for 15 seconds until
the shut-off with fault message occurs.
A new startup requires OFF or a key
switch reset.
15 A:1 A:30 A
Max. regular power of the turbine
In case of overload, the power is limited
to the set up value for 15 seconds until
the shut-off with fault message occurs.
A new startup requires OFF or a key
switch reset.
00:01:31
Adapting the LCD contrast in case of
sun exposure or increased constant
ambient temperatures.
Se-
quence
12
13
14
English 5.906-269.0 Rev. 00 (03/11)
Service
access
X
X
X
73