Metrologic MS9524 VoyagerPDF Series Installation And User Manual page 40

Single-line hand-held laser scanner
Hide thumbs Also See for MS9524 VoyagerPDF Series:
Table of Contents

Advertisement

D
S
ESIGN
PECIFICATIONS
E
LECTRICAL
Input Voltage:
DC Transformers:
Laser Class 1:
E
NVIRONMENTAL
Temperature:
Humidity:
Light Levels:
Contaminants:
Ventilation:
Specifications subject to change without notice.
36
5.0VDC ± 0.25V
Operating = 900 mW (typical)
Power:
Standby = 325 mW (typical)
Operating = 180 mA @ 5VDC (typical)
Current:
Standby = 65 mA @ 5VDC (typical)
Class 2; 5.2VDC @ 650 mA
IEC 60825-1:1993+A1:1997+A2:2001
EN 60825-1:1994+A11:1996+A2:2001
EMC:
FCC, ICES-003 & EN55022 Class B
Operating = 0°C to 40° (32° to 104°F)
Storage = -40°C to 60°C (-40°F to 140°F)
5% to 95% relative humidity, non-condensing
Up to 4842 Lux (450 footcandles)
Shock:
Designed to withstand 1.5 m (5') drops
Sealed to resist airborne particulate contaminants
None required