11.1 Error Code

11.1.1 Error Code
System error code
E198
E674
Printer error code
E000
E100
Communication error code
Error Code
0001
0003
0004
0009
0010
0011
0012
0013
0014
0016
0017
0018
0019
001A
001D
001E
0020
0021
0022
0023
0030
0031
0032
0033
0039
001F
003F
Error
Major cause/detection
code
Flash ROM write error.
Modem error.
Error
Major cause/detection
code
The thermistor has an open circuit or
a short circuit.
The heater has an open circuit. The
thermal fuse has blown.
The High-voltage power supply board
has a fault.
The DCNT board has a fault.
The scanner assembly has a fault.
Description
The sender may not be using a G3 fax machine.
Received DIS after sending DIS signal
Received DCN after sending DTC signal
The sender may not be using a G3 fax machine.
Received DCN signal after sending DTC signal in Polling Rx
The number of re-transmissions of the procedure signal has been exceeded
Remote side Password not match in Polling Rx
The procedure signal cannot be received for 6 sec while in wait.
Cannot receive signal after sending FTT signal
DCN was received through a non-normal procedure
Can't receive any response from remote side after sending
type of (PPS/EOR) EOM signal
Cannot detect energy within 6 sec after sending FTT command
Received DCN signal sending CFR signal
Fail to Receive Protocol for 6 Seconds when Waiting for Protocol during Reception
Detect flag but nothing after sending CFR signal
Timeout in V17 ECM Rx phase C
Can't correct frame within 6 sec or in no-ECM mode, one decoding line
over 6 sec
Memory has overflowed when receiving images
Owing to noise interference on the line, receiving side can't receive correct data
within specified time (no ECM)
Can't receive correct signal after sending CFR signal
Can't receive any signal within 6 sec after sending MCF signal.
Fault occurred in the communication procedure signal
Can't receive carrier within 6 sec after sending MCF or RTP, RTN signal
DCN was received through a non-normal procedure
In non-ECM mode, when machine already received the data but next line data
doesn't receive within 13.1 seconds
Can't detect any G3 signal within 35 sec after sending DTC signal
Remote side TSI not define in machine one touch or speed dial directory
T-11-1
Remedy
- Turn the power OFF and then back ON..
- Replace the SCNT board.
- Turn the power OFF and then back ON..
- Replace the SCNT board.
T-11-2
Remedy
- Check the connector of the fixing film unit.
- Replace the fixing film unit.
- Replace the High-voltage power supply board.
- Replace the DCNT board.
- Check the connector of the laser scanner assembly.
- Replace the laser scanner assembly.
- Replace the engine controller PCB.