Mercedes-Benz 2006 CLK-Class Coupe Operator's Manual page 383

Clk-class coupe
Table of Contents

Advertisement

Practical hints
What to do if ...?
Symbol messages
Display symbol Display message
#
Visit workshop
Low voltage
Charge battery
Low voltage
Switch off
consumers
382
Possible cause/consequence
The battery is no longer charging.
Possible causes:
broken poly-V-belt
alternator malfunctioning
The battery has insufficient voltage.
The battery has insufficient voltage.
Possible solution
Stop immediately in a safe location or
as soon as it is safe to do so and check
the poly-V-belt.
If it is broken:
Do not continue to drive. Otherwise
the engine will overheat due to an
inoperative water pump which may
result in damage to the engine. Notify
an authorized Mercedes-Benz Center.
If it is intact:
Drive immediately to the nearest
authorized Mercedes-Benz Center.
Start the engine ( page 48).
Turn off unnecessary electrical con-
sumers.