Biasi PARVA CONTROL M90.24SV User Manual And Installation Instructions page 62

Table of Contents

Advertisement

7. Extract the control panel as explained in
the section 5.11 of this manual.
8. Loosen the screws A and remove the
service panel (Fig. 7.57).
9. set correctly the dip-switch "2" (Fig. 7.58)
in accordance with the following table.
Gas supply
Zasilanie gazem
Natural gas/Gaz ziemny
L.P.G./Gaz płynny LPG
Fig. 7.57
10. Calibrate the gas valve according to the
instructions given in the section 6.5.
11. Set the correct gas pressure for central
heating output required, see section 6.7 in
this manual.
12. Stick on the inside of the left hand side
panel adjacent to the data badge the self-
adhesive
label
conversion kit) indicating the type of gas,
and the gas pressures to which the
appliance has been set.
13. Replace the service panel, the left hand-
side panel and the front panel of the case.
62
(included
with
the
Wysunąć
7.
zostało to objaśnione w pkt 5.11 niniejszej
instrukcji obsługi.
Zluzować śruby A i wyjąć panel obsługi
8.
(rys. 7.2).
ustawić prawidłowo mikroprzełącznik "2"
9.
(rys. 7.3) zgodnie z poniższą tabelą.
Position of dip-switch n.2
Pozycja mikroprzełącznika nr 2
On
/
Off
Wył.
/
Dokonać kalibracji zaworu gazowego
10.
zgodnie ze wskazówkami podanymi w
punkcie 6.5.
Ustawić prawidłowe wymagane ciśnienie
11.
gazu dla wyjścia instalacji ogrzewania
centralnego, patrz punkt 6.7 w niniejszej
instrukcji obsługi.
Przykleić od wewnątrz po lewej stronie
12.
płyty
samoprzylepną etykietkę (dołączoną do
zestawu zamiennego) z informacją o
rodzaju gazu, oraz wartościach ciśnień
gazu
na
nastawione.
Założyć z powrotem panel obsługi, lewą
13.
boczną płytę oraz płytę czołową obudowy.
moduł
sterowania
Fig. 7.58
obok
symbolu
jakie
urządzenie
tak
jak
danych
zostało

Hide quick links: