VOX DLY (VOX DELAY)
Function: Sets the "hang time" for the VOX circuitry.
Available Values: 100 ~ 3000 (ms) (100 ms/step)
Default: 500 (ms)
In VOX operation, sets the delay time when the trans-
mitter will return to receive after a voice pause.
The Delay time can be set while transmitting.
FT-450D O
PERATION
M
ANUAL
M
ENU
VOXGAIN
Function: Sets the gain of the VOX circuitry's input
audio detector.
Available Values: 1 ~ 100
Default: 50
The sensitivity is least at "1", and maximum at "100".
The VOX operation sensitivity can be set while trans-
mitting.