Cause: Amplifier IC is abnormal.
Turning on the power without correcting the cause will
trigger the protection function to work 2 second later to
shut off the power supply.
Cause: Control section is abnormal.
If there is an abnormality between the microprocessor and
DSP, the protection function works 25 seconds later and
the power is turned off.
• History of protection function
When the protection function has worked, its history is
stored in memory with a backup. Even if no abnormal-
ity is noted while servicing the unit, an abnormality
which has occurred previously can be defined as long
as the backup data has been stored.
The history of the protection function is cleared when
self-diagnostic function is cancelled by selecting PRE-
SET RESERVED (Memory initialized) of main menu
No. 8 or when the backup data is erased.
* To clear the protection history only, use the sub-
menu No. 6 "PROTECT Hist (PrHist <- RESET) of
main menu No. 20".
Version (1 alphabet)
バージョン (英1文字)
D-I_PROTECT C
原因: アンプICが異常。
異常状態のまま電源オンすると、2秒後にプロテクション
がかかり、電源が切れます。
DIG MUTE PRT
原因: 制御部が異常。
マイコンとDSPとの間で異常があると、25秒後にプロテク
ションがかかり、電源が切れます。
● プロテクションの履歴
プロテクションが働いた場合、履歴をバックアップし
て記憶しています。サービスのときに異常が認められ
なくても、バックアップが残っていれば、お客様のと
ころで起きた異常を区別できます。
プロテクションの履歴は、メインメニューNo. 8で
PRESET RESERVED (メモリーの初期化) を選んでダ
イアグを解除した場合や、バックアップが消えたとき
にはクリアされます。
※ プロテクション履歴のみクリアしたい場合は、メイ
ンメニューNo.20のサブメニューNo. 6 " PROTECT
Hist (PrtHist←RESET) " でクリアできます。
YSP-600/HTY-760