SERVICE ALARM
BOTH
SET
SCHEDULED SERVICE
0.25
YR
SET
SCHEDULED SERVICE
80000
GAL
SET
RETURN TO NORMAL MODE
Reset Diagnostic Values: Hold
DAYS SINCE REGEN
2
DAY
SINCE LAST REGEN
342
GAL
USAGE HISTORY
108
1
DAY
GAL
13

ServiCe reMinDer

STEP 26S – Set scheduled service display using  or  buttons. Available options are OFF, TIME,
Step 26S
ON GAL or BOTH. Selecting OFF disables this feature. If OFF is selected, press NEXT to exit
System Setup. If TIME, ON GAL or BOTH is selected press NEXT to select the TIME and/or ON
GAL values. See Steps 27S and/or 28S. When days fall below 1 year, display shows "SCHED-
ULED SERVICE in XXX DAYS", so service technician can reprogram if desired. This can also acti-
vate relay if Service Alarm is selected on Step 21S. Press REGEN to return to the previous step.
STEP 27S – Service alarm for TIME ranges from 0.25 to 9.75 years. Press  and  buttons to-
Step 27S
gether until "set" appears to select value. Press NEXT to either exit System Setup or if BOTH was
selected go to Step 28S. Press REGEN to return to the previous step. When time selected and
# of days drops below 1 year, the display in OEM program will show "scheduled service in XXX
days" right after screen where service reminder is programmed.
Step 28S
STEP 28S – Service alarm for ON GAL ranges from 100 to 9,999,900 gallons. Press  and 
buttons together until "set" appears, use arrows to select value. Press NEXT to exit System Setup.
Press REGEN to return to the previous step.
Reset service reminder by pressing up and down arrows together when reminder is dis-
played.
=  Up Arrow
NEXT/DOWN buttons for 3 seconds, then hold
STEP 1D – Press  or  simultaneously for three seconds. If screen in step 2D does not
STEP 1D
appear in 5 seconds the lock on the valve is activated.
STEP 2D – Days, since last regeneration: This display shows the days since the last regenera-
STEP 2D
tion occurred. Press the NEXT button to go to Step 3D. Press REGEN to exit Diagnostics.
STEP 3D – Volume, since last regeneration: This display shows gallons of water that has been
STEP 3D
treated since the last regeneration. This display will equal zero if a water meter is not installed.
Press the NEXT button to go to Step 4D. Press REGEN to return to previous step.
STEP 4D – Volume of water used, 63-day usage history: This display shows day 0 (for today)
STEP 4D
and 1 (for yesterday) will show day 2 (which would be the day before yesterday) and flashes the
volume of water treated on that day. Continue to press the  button to show the volume of water
treated for the last 63 days. If a regeneration occurred on the day, the "letter R" will also be dis-
played. This display will show dashes if a water meter is not installed. Press the NEXT button at
any time to go to Step 5D. Press REGEN to return to the previous step.

DiAGnOSTiCS

=  Down Arrow
UP/DOWN buttons for 3 seconds.