Hellenbrand ProMate Series Owner's Manual page 12

Hellenbrand promate series twin alt manual
Table of Contents

Advertisement

RELAY 1 SET POINT
SET
RELAY 1 DURATION
0:01
SET
RELAY 1 SERV ALARM
TRIGGER
SET
RELAY 1 LOCKOUT
TRIGGER
SET
RELAY 1 SETPOINT
SET
RELAY 1 DURATION
70:00
SET
RELAY 2 TRIGGER
REGEN
GAL
SET
12
Step 19S
1
GAL
Step 20S
MIN
Step 21S
Step 22S
Step 23S
-20
MIN
Step 24S
MIN
STEP 25S –
Relay 2 programming includes identical options as Relay 1 with the addition of the
Step 25S
ability to trigger Relay 2 in Error Mode. Relay closes when ever control enters Error Mode and
immediately deactivates when error resolved and control reset. Press NEXT to go to Step 26S.
STEP 19S – Use up and down arrows to select number of gallons per relay
activation of regen gallon setting.
Range: 0.1 -20,000 gallons. Press NEXT to go to Step 20S.
STEP 20S –
If Off or Time was selected in previous steps, this screen does not
appear. Use up and down arrows to set duration of relay activation in minutes.
Range = 0:01 (1 second) - 500:00 (500 minutes). Press NEXT to go to Step 25S.
Press REGEN to return to previous step.
STEP 21S
Service Alarm chosen to activate relay, relay closes whenever Service Alarm
has triggered. Programming for service reminder is done on Step 26S. Relay
opens when service alarm reset. Press NEXT to go to Step 25S to set Relay 2
Settings. If off selected for
Relay 2, service reminder programming on Step 26S.
• Relay closes on Gallons
• Relay closes on Time
• Relay closes on Both
• Off, Factory setting is off
STEP 22S
Relay Triggered for Lockout, relay closes a set time before or after the start of
regeneration. The start of regeneration is first backwash or draw cycle. Negative
start time delays regeneration by that amount. Relay remains activated during
ERROR, after power failure and after manual advance. Soft reset deactivates
relay. Access REGEN setting by pressing DOWN arrow through all the negative
numbers in time setting. Press NEXT to Set Start Time.
STEP 23S
Use up or down arrows to select minutes of relay activation. Range = -20 – 500
minutes. Press NEXT to select duration of relay activation. You may select
REGEN if relay activation is desired for complete regeneration.
STEP 24S
Use up or down arrows to select duration of relay activation. Range = 0:01
(1 second) - 500:00 (500 minutes). Press NEXT to go to Relay 2 programming.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents