Table F-1. Basic Troubleshooting Steps (Continued)
Condition ...
Possible Problem ...
IV. Debug prompt
A. The initial
debugger
177-Bug>
environment
appears at
parameters may be
powerup, but the
set wrong.
board does not
auto boot.
B. There may be
some fault in the
board hardware.
Try This ...
1. Start the onboard calendar clock and timer.
Type
set mmddyyhhmm <CR>
where the characters indicate the month, day,
year, hour, and minute. The date and time will
be displayed.
Performing the
!
next step will
change some
Caution
parameters that
may affect your
system
operation.
2. Type in
env;d <CR>
This sets up the default parameters for the
debugger environment.
3. When prompted to Update Non-Volatile
RAM, type in
y <CR>
4. When prompted to Reset Local System, type
in
y <CR>
5. After clock speed is displayed, immediately
(within Þve seconds) press the Return key
<CR>
or
BREAK
to exit to System Menu. Then enter a 3 ÒGo to
System DebuggerÓ and Return
3 <CR>
Now the prompt should be
177-Diag>
(continues>)