Programming System Option Sections; Exiting Installer Programming - DSC WLS900 Installation Manual

Hide thumbs Also See for WLS900:
Table of Contents

Advertisement

5 C: Programming System Option Sections
System Options Programming Sections are used to enable or
disable various system functions. When a System Options Section
is entered, a message similar to the one shown here will be
displayed.
Section Number indicates which Section is being programmed.
Selected Options indicate which options have been enabled or
disabled by displaying the numbers 1 through 8.
Refer to the Programming Sections part of this manual and the
Programming Work Sheets for information on the features
programmed in each System Options Programming Section. To
enable or disable functions, enter a number from 1 to 8; the
number will either be added to or removed from the display.
To add all numbers to the display, press [9]. To clear all numbers
from the display, press [0]. Be sure to refer to the Programming
Sections and Work Sheets to determine the status of each feature
when its number is displayed or not displayed.
To exit, press the [#] Key to return to the "Enter Program Section"
message.
5 D: Exiting Installer Programming
To exit the Installer Programming Mode, press the [#] Key when
this message is displayed; the Keypad will return to its inactive
state.