[F], [A] and [P] Key Alarms: The PGM output switches to ground when any of the keypad alarms are
generated by pressing the [F], [A] or [P] Keys. The PGM output will be activated until the Bell Cut-off time
expires or until an Access Code is entered.
[9]
Arm/Disarm Status: The PGM is activated when the system is armed and remains activated throughout
the armed period. When the system is disarmed, the PGM output will be deactivated.
[5]

1st System Option Code

When Section [5] is entered, the 4 Zone Lights will indicate which options are selected.
To select an option, press a number from [1] to [4]. If the light indicating the option was OFF, it will come ON;
if the light indicating the option was ON, it will go OFF.
LIGHT
[1]
ON =
• OFF =
[2] • ON =
OFF =
[3]
ON =
• OFF =
[4] • OFF =
• Factory default settings
Notes on [P] Key Operation
If the [P] Key is programmed as a silent alarm, it is suggested that one of the Programmable Outputs be
programmed with Option 3, Option 4, or Option 8 so that an output is activated when the [P] Key is pressed.
The Programmable Output may be used to activate special lighting or a bell or siren other than the one
connected to the control panel.
If the [P] Key is not to activate a Programmable Output, do not program the [P] Key as a silent alarm. If enabled
but not set to activate a Programmable Output or sound an alarm, no alarm will be generated when the [P] Key
is pressed. Ensure that the user is made fully aware of how the [F], [A] and [P] Keys function on their system.
Notes on KEY Terminal Options
When Light [3] is ON, the KEY Terminal will function as a Tamper Zone.
When Light [3] if OFF (the default setting), the KEY Terminal will be used for Keyswitch Operation.
When used as a Tamper Zone, the KEY Terminal functions as a regular burglary zone. If PGM1 or PGM2 are
programmed with Programmable Output Option [4] Burglar Alarm / [P] Key, the output will be activated if an
alarm is generated on the KEY Terminal.
12
Momentary-contact Keyswitch Arming
Maintained-contact Keyswitch Arming
[P] Key silent
[P] Key audible
KEY Terminal operates as Tamper Zone
KEY Terminal used for Keyswitch Operation
For Future Use