Alarm Reporting Codes, Zones 1 To 10; Restoral Reporting Codes, Zones 1 To 10; Closing (Arming) Reporting Codes, Access Codes 0 To 9; Opening (Disarming) Reporting Codes, Access Codes 0 To 9 - DSC WLS900 Installation Manual

Hide thumbs Also See for WLS900:
Table of Contents

Advertisement

Chapter 9: Communications Programming Sections
[23]
Program ten 2-digit alarm reporting codes for Zones 1 through 10.
Note that the use of different communications formats may determine how the Account and
reporting codes are to be programmed. The examples below illustrate how different
communication formats require different Account numbers and reporting codes.
3/1 Format, Single Line or Non-Extended Reporting
Requires:
• 3-digit Account Code in Section [22]. For example, program the Account Code as [1230]
• Format [0], [1], [2], [3], [4], [5] or [6] in Section [41] Communication Formats
• Single digit alarm reporting codes in Section [23]. For example, program [30] for the
Transmission Sent: 123 3
4/2 Format, Single Line Reporting
Requires:
• 4-digit Account Code in Section [22]. For example, program [1234] for Account Code
• Format [0], [1], [2], [3], [4], [5] or [6] in Section [41] Communication Formats
• Two-digit alarm reporting codes in Section [23]. For example, program [31] for the 2-digit
Transmission Sent: 1234 31
[24]
Program ten 2-digit zone restoral reporting codes in this section. These codes will be
transmitted for restorals on zones 1 through 10. Refer to Section [23] for programming
instructions.
[25]
Program ten 2-digit Closing Reporting Codes in this section; refer to Programming Section [23]
for programming instructions. These codes are used to report arming by Access Code.
The Closing Code will be transmitted immediately after the Exit Delay expires. If the system is
armed and then disarmed before the Exit Delay expires, no transmission will be made.
Note that Access Code 0 is the Master Code, and the Access Code 9 may be programmed to
function as a normal Access Code or as a One-Time Use Code. See Section 8-05-4.
When the system is armed with one or more zones manually bypassed, the monitoring station
can be advised of this by programming the Partial Closing Code in Section [38]. The Partial
Closing Code will only be transmitted with the Access Code Closing Code when the system has
been armed with manually bypassed zones.
[26]
Program ten 2-digit Opening Reporting Codes in this section; refer to Programming Section [23]
for programming instructions. These codes are used to report disarming by Access Code.
[27]
Program ten 2-digit Tamper Reporting Codes in this section; refer to Programming Section [23]
for programming instructions. These codes will be transmitted to report tampers on zones 1
through 10. Tamper transmissions follow the Swinger Shutdown Counter (refer to Section 39).
[28]
Program ten 2-digit Tamper Restoral Reporting Codes in this section; refer to Programming
Section [23] for programming instructions. These codes will be transmitted to report tamper
restorals on zones 1 through 10. Tamper Restoral transmissions follow the Swinger Shutdown
Counter (refer to Section 39).
32

Alarm Reporting Codes, Zones 1 to 10

for Account Code 123
single-digit reporting code 3
1234
reporting code 31.

Restoral Reporting Codes, Zones 1 to 10

Closing (Arming) Reporting Codes, Access Codes 0 to 9

Opening (Disarming) Reporting Codes, Access Codes 0 to 9

Tamper Reporting Codes, Zones 1 to 10

Tamper Restoral Reporting Codes, Zones 1 to 10