[37]

Keypad and Sounder Restoral Reporting Codes

Program eight 2-digit Maintenance Restoral Reporting Codes in this section; refer to
Programming Section [23] for programming instructions.
Reporting codes for the following events are programmed in this section:
1 Sounder 1 Tamper Restoral
2 Sounder 2 Tamper Restoral
3 Sounder 1 Supervisory Restoral
4 Sounder 2 Supervisory Restoral
5 Keypad 1 Tamper Restoral
6 Keypad 2 Tamper Restoral
7 Keypad 1 Supervisory Restoral
8 Keypad 2 Supervisory Restoral
Tamper transmissions follow the Swinger Shutdown Feature (refer to
Section 39 Item 01).
[38]

Additional System Reporting Codes.

Program ten 2-digit Reporting Codes in this section; refer to Programming Section [23] for
programming instructions. To disable a code, program, "00" or "FF". Reporting Codes for the
following events are programmed in this section:
Failure to Communicate
A Failure to Communicate (FTC) code will be transmitted on the next successful
communication attempt following a communication failure. An FTC occurs when the
communicator is unsuccessful in communicating with the monitoring station after eight
attempts to each telephone number programmed.
RF Jam Detect
The RF Jam Detect code will be transmitted if the system detects an attempt to jam RF
signals or if all enrolled zones generate supervisory alarms. This code advises the
monitoring station that the Controller cannot communicate with system components and that
service is required.
Periodic Test Transmission
The Periodic Test Transmission code will be transmitted at a regular interval to confirm that
the system is able to communicate with the monitoring station. The code will be transmitted
according to the Test Transmission Cycle time programmed in Section [39] and the Test
Transmission Time of Day programmed in Section [40]. To disable the Periodic Test
Transmission, program Section 39 as hexadecimal "FF".
Installer Lead-in Code
The Installer Lead-in Code is transmitted whenever the Installer's Code is entered.
Installer Lead-out Code
The Installer Lead-out Code is transmitted when the Installer's Programming Mode is exited.
Downloading Lead-in Code
The Downloading Lead-in Code will be transmitted when the system initiates a call to the
downloading computer during User-Initiated, Installer-Initiated, Call Back or Periodic
Downloading.
Downloading Lead-out Code
The Downloading Lead-out Code is transmitted to the monitoring station when downloading
initiated by the Controller is completed.
Partial Closing Code
The Partial Closing Code will be transmitted with the Closing Reporting Code whenever the
system is armed with bypassed zones.
Opening After Alarm
The Opening After Alarm code will be transmitted with the Opening Reporting Code
whenever the system is disarmed after an alarm.
Telephone Line Monitor Restoral Code
The Telephone Line Monitor Restoral Code is transmitted when Telephone Line Monitor
trouble is restored.