Programming Toggle Option Sections

Some programming sections contain several toggle options.
The panel will use zone lights 1 through 8 to indicate if the
different options are enabled or disabled. Press the number
corresponding to the option to turn it ON or OFF. Once all the
toggle options have been selected correctly, press the [#] key
to exit the section and save the changes. The Ready light will
turn OFF and the Armed light will turn ON.
Refer to Section 5 in this manual to determine what each option
represents and whether the light should be ON or OFF for your
application.
4.5

Viewing Programming

LED Keypads
Any programming section can be viewed from an LED keypad.
When a programming section is entered, the keypad will
immediately display the first digit of information programmed in
that section.
V
T
O
V
P
R
The keypad displays the information using a binary format,
according to the following chart:
Value
Zone 1
Zone 2
Zone 3
Zone 4
Light On
Light Off
*
See Hex Data Entry instructions
Press any of the Emergency Keys (Fire, Auxiliary or Panic) to
advance to the next digit. When all the digits in a section have
been viewed, the panel will exit the section; the Ready Light will
turn OFF and the Armed light will turn ON, waiting for the next
three-digit programming section number to be entered. Press
the [#] key to exit the section
LCD Keypad
When a programming section is entered, the keypad will
immediately display all the information programmed in that
section. Use the arrow keys (< >) to scroll through the data being
displayed. Scroll past the end of the data displayed or press the
[#] key to exit the section.