U640 Setting Communication Time; Setting The One-Shot Detection Time For Remote Switching; Setting The Continuous Detection Time For Remote Switching - Kyocera FS-C2026MFP+ Service Manual

Hide thumbs Also See for FS-C2026MFP+:
Table of Contents

Advertisement

Item No.
U640
Setting communication time 1
Description
Sets the detection time when one-shot detection is selected for remote switching. (This setting
item will be displayed, but the setting made is ineffective.)
Sets the detection time when continuous detection is selected for remote switching. (This setting
item will be displayed, but the setting made is ineffective.)
Method
1. Press the start key.
2. Select the item to be set using the cursor up/down keys.
Display
Time (One)
Time (Cont)

Setting the one-shot detection time for remote switching

1. Change the setting using the cursor left/right keys.
Description
One-shot detection time for remote switching
2. Press the start key. The value is set.

Setting the continuous detection time for remote switching

1. Change the setting using the cursor left/right keys.
Description
Continuous detection time for remote switching
2. Press the start key. The value is set.
Completion
Press the stop key. The screen for selecting a maintenance item No. is displayed.
Description
Description
Sets the one-shot detection time for remote switching.
Sets the continuous detection time for remote switching.
1-3-39
Setting range
Initial setting
0 to 255
7
Setting range
Initial setting
0 to 255
80