Stun; Auto Reset Timer - Kenwood TK-3180 Function Reference

Hide thumbs Also See for TK-3180:
Table of Contents

Advertisement

The status of Transpond resets in the following
conditions.
Table 20-6 Condition to Reset the Transpond Status
Operation
One of the following keys is pressed.
• PF Monitor key
• PF Monitor Momentary key
• PF Squelch Off key
• PF Squelch Off Momentary key
• PF Zone Up key
• PF Zone Down key
Press a key.
• PF Zone Up/Down key
• PF CH/GID Up key
• PF CH/GID Down key
• PF CH/GID Up/Down key
• PF Scan key
• PF Home Channel key
• PF Direct CH/GID 1 - PF Direct CH/GID 5
key
On-hook
The microphone status becomes On-hook.
When transmitting using one of the following
switch or ports.
Transmission
• PTT switch
• PF Ext. PTT (Voice) port
• PF Ext. PTT (Data) port
!
Configuration using KPG-89D
Configuring the Transpond (Refer to FPRG 6.10.2
Decode tab - Transpond.)
Configuring the Alert Tone (Refer to FPRG 6.10.2
Decode tab - Alert Tone.)

20.3.3 Stun

Stun allows an administrator to remotely disable the
transceiver, using the DTMF function.
The transceiver overwrites the Stun Code on Tone and
starts Transpond function. Then, it performs the
operation configured in the Stun Code Response.
The operation configured in the Stun Code Response is
stored even if the transceiver is turned OFF. The
conditions of the Stun Response resets only when
receiving the Stun Reset code. It does not reset with the
Auto Reset Timer or the transceiver's operation.
You can configure the Stun Code and Stun Code
Response using KPG-89D.
Table 20-7 Stun Configuration
Operation
The Stun Code is a standby code of the
Stun Code
Stun function.
Version: 1.11
Conditions
Conditions
Function Reference
Operation
Stun Response is the
response when the Stun Code matches.
The following Stun Response operations
are available.
• TX Inhibit: The transceiver inhibits
transmission.
• Transceiver Inhibit: The transceiver
Stun Code Response
cannot transmit and receive.
Functions and operations of the
transceiver are also inhibited. The
transceiver emits the Warning Tone
when the PTT switch is pressed. The
Key-entry Error Tone sounds when a
key other than the PTT switch is
pressed.
Note:
" The transceiver does not enter Emergency Mode when the Stun
function is enabled.
" The transceiver does not automatically send the GPS data when
the Stun function is enabled.
!
Configuration using KPG-89D
Configuring the Stun Code (Refer to FPRG 6.10.2
Decode tab - Stun Code.)
Configuring the Stun Response (Refer to FPRG
6.10.2 Decode tab - Stun Response.)

20.3.4 Auto Reset Timer

The Auto Reset Timer is the duration from the time when
communication ends to the time when the DTMF match
state is reset.
You can configure the Auto Reset Timer using KPG-89D.
You can also configure the operation after the Auto Reset
Timer expires.
Table 20-8 Operation after the Auto Reset Timer Expires.
Auto Reset Timer
Disable
The Auto Reset Timer does not work.
The orange Selective Call Alert LED
LED
stops blinking when the Auto Reset
Timer expires.
The intermittently emitted Alert Tone
Alert
stops when the Auto Reset Timer
expires.
The match status of the DTMF resets
Monitor
when the Auto Reset Timer expires.
!
Configuration using KPG-89D
Configuring the Auto Reset Timer (Refer to FPRG
6.10.2 Decode tab - Auto Reset Timer.)
20 DTMF
Conditions
transceiver's
Operation
85