1 BASIC FUNCTION
1.2

Zone Description

Zone Data
Conventional
Conventional
Data
Data
Zone Data
Channel Data
Trunking System Data
Trunking System Data
Zone Data
Repeater Data
Group ID Data
Figure 1-3 Zone Description
You can configure Conventional Groups/Trunking
Systems for each Zone using KPG-89D.
You can configure a maximum of 128 Zones for each
transceiver.
Conventional Groups consist of Simplex and Semi-duplex
Conventional Channels.
Trunking Systems consist of Group IDs (GIDs) that utilize
the LTR (Logic Trunked Radio) Trunking protocol.
You can configure each Zone as a Conventional Group or
a Trunking System.
You can configure a maximum of 250 CH/GIDs for each
zone and a maximum of 512 CH/GIDs for each
transceiver.
Note:
" The number of Zones that you can configure varies depending
on the number of CH/GIDs and Repeaters.
" The number of CH/GIDs that you can configure to each Zone
varies depending on the number of Zones and Repeaters.
4
Conventional
Group
Data
Group
Group
Channel Data
Channel Data
Trunking System Data
Group ID Data
Group ID Data
1.3

Transmit/Receive Frequency

This is a frequency pair used for transmitting and
receiving data.
In Conventional Groups, you can configure the transmit/
receive frequencies for each channel using KPG-89D.
In Trunking Systems, you can configure transmit/receive
frequencies for each Repeater using KPG-89D.
Table 1-5 Transmit/Receive Frequency, Step
Model
TK-2180
TK-3180
TK-7180
TK-8180
*1: Supporting the updated version.
!
Configuration using KPG-89D
Configuring the transmit frequency and the receive
frequency to a channel. (Refer to 6.3.3 Receive
Frequency, 6.3.4 Transmit Frequency.)
Configuring the transmit frequency and the receive
frequency to the Home Repeater (Refer to 6.4.3
Receive Frequency and 6.4.4 Transmit
Frequency.)
1.4

Transmit Output Power

Select Low when a repeater or the receiving party is
nearby to save power.
This will extend the serviceable operation time of the TK-
2180/ 3180.
You can configure the transmit output power for each CH/
GID using KPG-89D.
Function Reference
Transmit/Receive Frequency
Type
Range [MHz]
K
136 - 174
400 - 470 *1
K
450 - 520
K
136 - 174
400 - 470 *1
K
450 - 520
Step [KHz]
2.5/ 5.0/ 6.25/ 7.5
5.0/ 6.25
2.5/ 5.0/ 6.25/ 7.5
5.0/ 6.25
Version: 1.11