9 Reference information
9.10 Available Curves
Curve
Sample flow
Sample flow
linear
UV 2nd
Sample pres-
sure
PreC pres-
sure
DeltaC pres-
sure
PostC pres-
sure
Conc Q1
Conc Q2
502
Range
0.001 to 50.000
ml/min (ÄKTA avant
25)
0.01 to 300.00 ml/min
(ÄKTA avant 150)
cm/h
-6000.000 to 6000.000
mAU
-1.00 to 10.00 MPa
(ÄKTA avant 25)
-1.00 to 5.00 MPa
(ÄKTA avant 150)
-1.00 to 20.00 MPa
(ÄKTA avant 25)
-1.00 to 5.00 MPa
(ÄKTA avant 150)
-1.00 to 20.00 MPa
(ÄKTA avant 25)
-1.00 to 5.00 MPa
(ÄKTA avant 150)
-1.00 to 20.00 MPa
(ÄKTA avant 25)
-1.00 to 5.00 MPa
(ÄKTA avant 150)
0.0% to 100.0%
0.0% to 100.0%
Sam-
Description
pling
frequen-
cy
1 Hz
The set flow rate of the sample
pump.
1 Hz
The set flow velocity of the
sample pump. Only available if
a column is selected.
10 Hz
The UV absorbance signal of
the U9-L monitor.
10 Hz
The sample pressure signal (at
the sample pump).
1 Hz
The pre-column pressure sig-
nal.
1 Hz
The delta-column pressure
signal.
1 Hz
The post-column pressure sig-
nal.
0.5 Hz
The set concentration of Q1 or
the current value during a
quaternary or BufferPro gradi-
ent
0.5 Hz
The set concentration of Q2 or
the current value during a
quaternary or BufferPro gradi-
ent
ÄKTA avant User Manual 29035184 AE