Manuals and User Guides for Waters TQ Detector. We have
2
Waters TQ Detector manuals available for free PDF download: Operator's Manual, Quick Start Manual
Waters TQ Detector Operator's Manual (235 pages)
Brand:
Waters
| Category:
Measuring Instruments
| Size: 1 MB
Table of Contents
Copyright Notice
2
Trademarks
2
Customer Comments
3
Safety Considerations
4
Considerations Specific to the TQ Detector
4
Operating this Instrument
7
Applicable Symbols
7
Intended Use
7
Calibrating
7
Quality Control
8
ISM Classification
9
EC Authorized Representative
9
Table of Contents
11
1 Waters TQ Detector
18
Overview
18
ACQUITY TQD UPLC/MS System
20
Software and Data System
21
ACQUITY UPLC Console
22
Ionization Techniques and Source Probes
23
Electrospray Ionization (ESI)
23
Combined ESI and APCI (Esci)
23
Atmospheric Pressure Chemical Ionization
24
Atmospheric Pressure Photoionization
24
Ion Optics
25
MS Operating Modes
26
MS/MS Operating Modes
27
Product (Daughter) Ion Mode
27
Precursor (Parent) Ion Mode
28
Multiple Reaction Monitoring Mode
28
Constant Neutral Loss Mode
29
Sample Inlet
30
Leak Sensors
30
Vacuum System
31
Rear Panel
31
Intellistart Fluidics System
33
Overview
33
System Operation
34
2 Preparing for Operation
36
Starting the Instrument
36
Configuring Intellistart
39
Verifying the Instrument's State of Readiness
39
Tuning and Calibration Information
39
Running the Instrument at High Flow Rates
40
Monitoring the Instrument Leds
40
Preparing the Intellistart Fluidics System
41
Installing the Solvent Manifold Drip Tray
41
Installing the Reservoir Bottles
42
Diverter Valve Positions
44
Purging the Infusion Syringe
46
Rebooting the Instrument
46
Rebooting the Instrument by Pressing the Reset Button
47
Leaving the Mass Spectrometer Ready for Operation
48
Emergency Instrument Shutdown
48
3 ESI and Esci Modes of Operation
50
Introduction
50
Installing the ESI Probe
50
Installing the Corona Pin
54
Optimizing the ESI Probe for Esci Operation
56
Removing the Corona Pin
56
Removing the ESI Probe
58
4 Optional APCI Mode of Operation
62
Atmospheric Pressure Chemical Ionization
62
Ionsabre APCI Probe
62
Installing the Ionsabre APCI Probe
63
Installing the Corona Pin
66
Removing the Corona Pin
66
Removing the Ionsabre APCI Probe
67
5 Maintenance Procedures
69
Maintenance Schedule
71
Spare Parts
73
Troubleshooting with Connections INSIGHT
73
Safety and Handling
74
Preparing the Instrument for Work Performed on the Source
75
Operating the Source Isolation Valve
76
Removing O-Rings and Seals
78
Cleaning the Instrument's Exterior
79
Emptying the Exhaust Trap Bottle
79
Emptying the Roughing Pump Exhaust Liquid Trap Bottle
81
Gas Ballasting the Roughing Pump
83
Gas Ballasting a Pump Fitted with a Screwdriver-Operated Gas Ballast Valve
84
Gas Ballasting a Pump Fitted with a Handle-Operated Gas Ballast Valve
85
Checking the Roughing Pump Oil Level
86
Adding Oil to the Roughing Pump
86
Cleaning the Source Components
88
Cleaning the Sample Cone and Gas Cone
88
Removing the Cone Gas Assembly from the Source
88
Disassembling the Cone Gas Assembly
91
Cleaning the Sample Cone and Gas Cone
92
Assembling the Cone Gas Assembly
95
Fitting the Cone Gas Assembly to the Source
96
Cleaning the Ion Block, Isolation Valve, and Extraction Cone
98
Removing the Ion Block Assembly from the Source Assembly
98
Disassembling the Source Ion Block Assembly
100
Cleaning the Ion Block, Isolation Valve, and Extraction Cone
108
Assembling the Source Ion Block Assembly
110
Fitting the Ion Block Assembly to the Source Assembly
113
Cleaning the Source Hexapole Assembly
115
Removing the Ion Block Assembly, Ion Block Support, and Hexapole from the Source Assembly
115
Cleaning the Hexapole Assembly
117
Fitting the Hexapole Assembly, PEEK Ion Block Support, and Ion Block Assembly to the Source Assembly
120
Replacing the ESI Probe Tip
122
Replacing the ESI Probe Sample Capillary
123
Cleaning the Ionsabre APCI Probe Tip
130
Replacing the Ionsabre APCI Probe Sample Capillary
130
Removing the Existing Capillary
130
Installing the New Capillary
135
Cleaning or Replacing the Corona Pin
139
Replacing the APCI Probe Heater
140
Replacing the Ion Block Source Heater
142
Replacing the Source Assembly Seals
147
Removing the Source Enclosure from the Instrument
147
Disassembling the Source Enclosure and Probe Adjuster Assembly
150
Removing the Seals from the Source Enclosure and Probe Adjuster Assembly
151
Fitting the New Source Enclosure and Probe Adjuster Assembly Seals
154
Assembling the Probe Adjuster Assembly and Source Enclosure
155
Fitting the Source Enclosure to the Instrument
156
Maintaining the Instrument Air Filters
158
Cleaning the Air Filter Inside the Instrument's Lower Bezel
158
Replacing the Air Filter Inside the Lower Bezel
159
Cleaning the Air Filter Behind the Source Probe
160
Fit the Probe to the Source
161
Replacing the Air Filter Behind the Source Probe
162
Replacing the Roughing Pump Oil
163
If You Are Fitting an ESI Probe, See "Installing the ESI Probe" on Page
163
If You Are Fitting an Ionsabre APCI Probe, See "Installing the Ionsabre APCI Probe" on Page
163
Start the Instrument (See "Starting the Instrument
165
Replacing the Roughing Pump's Oil Demister Element
166
A Safety Advisories
177
Warning Symbols
177
Task-Specific Hazard Warnings
177
Specific Warnings
178
Caution Symbol
180
Warnings that Apply to All Waters Instruments
180
Electrical and Handling Symbols
186
Electrical Symbols
186
Handling Symbols
187
B External Connections
189
External Wiring and Vacuum Connections
189
Connecting the Oil-Filled Roughing Pump
190
Making the Electrical Connections for a Roughing Pump with an External Relay Box
195
Making the Electrical Connections for a Roughing Pump Without an External Relay Box
196
Connecting the Oil-Free Roughing Pump
197
Making the Electrical Connections for an Oil-Free Roughing Pump
204
Connecting to the Nitrogen Gas Supply
205
Connecting to the Collision Cell Gas Supply
207
Connecting the Nitrogen Exhaust Line
207
Connecting the Liquid Waste Line
210
Connecting the Workstation
212
Connecting Ethernet Cables
213
I/O Signal Connectors
213
Signal Connections
215
Connecting to the Electricity Source
218
C Materials of Construction and Compliant Solvents
221
Preventing Contamination
221
Items Exposed to Solvent
221
Solvents Used to Prepare Mobile Phases
222
Assembling Required Materials
225
Preparing the Sulfadimethoxine Standard
225
Storing the Solutions
226
Using the Solution in an LC/MS System Check Run
226
500 D Preparing Samples, LC/MS System Check, Empower Software
225
Index
228
Advertisement
Waters TQ Detector Quick Start Manual (92 pages)
Brand:
Waters
| Category:
Security Sensors
| Size: 1 MB
Table of Contents
Safety Considerations
4
Instrument-Specific Safety Considerations
4
Flammable Solvents Hazard
5
High Temperature Hazard
5
High Voltage Hazard
6
Safety Advisories
6
Operating this Device
7
Symbols
7
Intended Use
7
Calibration
8
Quality Control
8
IVD Authorized Representative Information
9
IVD Authorized Representative
9
Table of Contents
11
1 Waters TQ Detector Overview
15
Overview
16
Waters TQ Detector
16
ACQUITY TQD UPLC/MS System
18
Masslynx Mass Spectrometry Software and Data System
19
ACQUITY UPLC Console
20
Ionization Techniques and Source Probes
21
Electrospray Ionization (ESI)
21
Combined Electrospray Ionization and Atmospheric Pressure Chemical Ionization (Esci)
21
Atmospheric Pressure Chemical Ionization
22
Atmospheric Pressure Photoionization
22
Ion Optics
23
MS Operating Modes
24
MS/MS Operating Modes
25
Product (Daughter) Ion Mode
25
Precursor (Parent) Ion Mode
26
Multiple Reaction Monitoring Mode
26
Constant Neutral Loss Mode
27
Sample Inlet
28
Vacuum System
28
Rear Panel
29
Intellistart Fluidics System Overview
30
Intellistart Fluidics System Operation
31
Operating the Intellistart Fluidics System from the ACQUITY UPLC Console
31
Operating the Intellistart Fluidics System from the Tune Window
32
Programming the MS Method to Operate the Intellistart Fluidics System
32
2 Preparing the Waters TQ Detector for Operation
35
Starting the TQ Detector
36
Configuring Intellistart
40
Verifying the Instrument's State of Readiness
40
Tuning and Calibration Information
40
Running the TQ Detector at High Flow Rates
41
Monitoring the TQ Detector Leds
42
Preparing the Intellistart Fluidics System
43
Installing the Solvent Manifold Drip Tray
43
Installing the Reservoir Bottles
44
Diverter Valve Positions
45
Purging the Infusion Syringe
47
Rebooting the TQ Detector
48
Rebooting the TQ Detector by Pressing the Reset Button
48
Shutting down the TQ Detector
49
Putting the TQ Detector in Standby Mode for Overnight Shutdown
49
Complete TQ Detector Shutdown
50
Emergency TQ Detector Shutdown
51
3 ESI and Esci Modes of Operation
53
Introduction
54
Installing the ESI Probe
54
Required Materials
54
Installing the Corona Pin
57
Required Materials
57
Optimizing the ESI Probe for Esci Operation
59
Required Materials
59
Removing the Corona Pin
61
Required Materials
61
Removing the ESI Probe
63
Required Materials
63
4 Operating the Waters TQ Detector
65
Setting-Up the Instrument
66
Required Materials
66
Performing a Sample Tune
71
Required Materials
71
Developing Experiment Methods
73
Required Materials
73
Verifying the System Using System QC
75
A Safety Advisories
80
Warning Symbols
80
Task-Specific Hazard Warnings
80
Warnings that Apply to Particular Instruments, Instrument Components, and Sample Types
81
Caution Symbol
83
Warnings that Apply to All Waters Instruments
83
Electrical and Handling Symbols
91
Electrical Symbols
91
Handling Symbols
92
Advertisement
Related Products
Waters ThermaBeam Mass
Waters TA Instruments Sample/Temperature Stage
Waters Therapy Shower
Waters TRIZAIC UPLC
Waters 2414
Waters 2432
Waters 2465
Waters 2475
Waters 2487 Dual A
Waters 2489
Waters Categories
Laboratory Equipment
Security Sensors
Control Unit
Measuring Instruments
Water Pump
More Waters Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL