Sign In
Upload
Manuals
Brands
VIPA Manuals
Control Unit
System 300S
VIPA System 300S Manuals
Manuals and User Guides for VIPA System 300S. We have
12
VIPA System 300S manuals available for free PDF download: Manual
VIPA System 300S Manual (228 pages)
HB140
Brand:
VIPA
| Category:
Control Systems
| Size: 10 MB
Table of Contents
Table of Contents
3
1 General
6
Copyright © VIPA Gmbh
6
About this Manual
7
Safety Information
8
2 Basics
10
Safety Information for Users
10
Operating Structure of a CPU
11
General
11
Applications
11
Operands
12
Cpu 314-6Cf03
13
General Data
16
3 Assembly and Installation Guidelines
18
Overview
18
Installation Dimensions
18
Assembly SPEED-Bus
20
Assembly Standard Bus
23
Cabling
25
Installation Guidelines
27
4 Hardware Description
31
Properties
31
Structure
32
General
32
Interfaces
32
Memory Management
34
Storage Media Slot
34
Battery Backup for Clock and RAM
35
Operating Mode Switch
36
Leds
36
In-/Output Range CPU 314-6CF03
39
Technical Data
41
5 Deployment CPU 314-6CF03
54
Assembly
54
Start-Up Behavior
54
Addressing
55
Overview
55
Address Assignment I/O Part
58
Hardware Configuration - CPU
59
Hardware Configuration - I/O Modules
60
Hardware Configuration - Ethernet PG/OP Channel
61
Hardware Configuration - SPEED-Bus
63
Preconditions
63
Proceeding
64
Setting Standard CPU Parameters
64
Parameterization Via Siemens CPU
64
Parameters CPU
65
Parameters for DP
67
Parameters for MPI/DP
68
Setting VIPA Specific CPU Parameters
69
Proceeding
69
VIPA Specific Parameters
71
Project Transfer
74
Transfer Via MPI/PROFIBUS
74
Transfer Via Ethernet
76
Transfer Via MMC
77
Access to the Internal Web Page
78
Operating Modes
81
Overview
81
Function Security
83
Overall Reset
84
Firmware Update
85
Reset to Factory Settings
88
Slot for Storage Media
89
Memory Extension with MCC
90
Extended Know-How Protection
91
CMD - Auto Commands
92
Diagnostic Entries
94
Control and Monitoring of Variables with Test Functions
127
6 Deployment I/O Periphery
129
Overview
129
In-/Output Range CPU 314-6CF03
130
Address Assignment I/O Part
132
Analog Part
134
Analog Part - Parametrization
138
Analog Part - Diagnostic Functions
142
Digital Part
145
Counter - Fast Introduction
147
Counter - In-/Output Area
149
Counter - Parametrization
152
Counter - Functions
159
Counter - Additional Functions
164
Counter - Diagnostic and Interrupt
171
Process Interrupt
171
Diagnostic Interrupt
172
7 Deployment Ptp Communication
178
Fast Introduction
178
Principle of the Data Transfer
179
Deployment of RS485 Interface for Ptp
179
Hb140 | Cpu | 314-6Cf03 | Gb
179
Parametrization
182
FC/SFC 216 - SER_CFG - Parametrization Ptp
182
Communication
183
FC/SFC 217 - SER_SND - Send to Ptp
183
FC/SFC 218 - SER_RCV - Receive from Ptp
183
Protocols and Procedures
183
Modbus - Function Codes
187
Modbus - Example Communication
192
8 Deployment PROFIBUS Communication
194
Overview
194
Fast Introduction
195
Hardware Configuration - CPU
195
Deployment as PROFIBUS DP Master
196
Deployment as PROFIBUS DP Slave
197
PROFIBUS Installation Guidelines
200
Commissioning and Start-Up Behavior
203
9 Winplc7
205
System Conception
205
Installation
205
Example Project Engineering
207
Job Definition
207
Project Engineering
207
Test the PLC Program in the Simulator
213
Transfer PLC Program to CPU and Its Execution
214
10 Configuration with TIA Portal
216
TIA Portal - Work Environment
216
General
216
Work Environment of the TIA Portal
216
TIA Portal - Hardware Configuration - CPU
217
TIA Portal - Hardware Configuration - I/O Modules
218
TIA Portal - Hardware Configuration - Ethernet PG/OP Channel
219
TIA Portal - Setting VIPA Specific CPU Parameters
222
TIA Portal - VIPA-Include Library
225
TIA Portal - Project Transfer
226
Advertisement
VIPA System 300S Manual (179 pages)
Brand:
VIPA
| Category:
Control Unit
| Size: 5 MB
Table of Contents
Table of Contents
3
1 General
6
Copyright © VIPA Gmbh
6
About this Manual
7
Safety Information
8
2 Basics
10
Safety Information for Users
10
Operating Structure of a CPU
11
General
11
Applications
11
Operands
12
Cpu 315-4Pn43
13
General Data
14
3 Assembly and Installation Guidelines
17
Installation Dimensions
17
Assembly Standard Bus
18
Cabling
19
Installation Guidelines
20
4 Hardware Description
24
Properties
24
Structure
25
General
25
Interfaces
25
Memory Management
26
Storage Media Slot
27
Battery Backup for Clock and RAM
27
Operating Mode Switch
28
Leds
28
Technical Data
30
5 Deployment CPU 315-4PN43
39
Assembly
39
Start-Up Behavior
39
Addressing
40
Overview
40
Addressing Backplane Bus I/O Devices
40
Hardware Configuration - CPU
41
Hardware Configuration - I/O Modules
42
Hardware Configuration - Ethernet PG/OP Channel
43
Hardware Configuration - Communication
45
Setting Standard CPU Parameters
45
Parameterization Via Siemens CPU
45
Parameters CPU
46
Parameters for MPI/DP
50
Setting VIPA Specific CPU Parameters
50
Proceeding
50
VIPA Specific Parameters
52
Project Transfer
52
Transfer Via MPI
53
Transfer Via Ethernet
54
Transfer Via Memory Card
54
Accessing the Web Server
55
Operating Modes
60
Overview
60
Function Security
62
Overall Reset
63
Firmware Update
65
Reset to Factory Settings
67
Slot for Storage Media
68
Memory Extension
69
Extended Know-How Protection
70
CMD - Auto Commands
72
Diagnostic Entries
74
Control and Monitoring of Variables with Test Functions
107
6 Deployment Ptp Communication
109
Fast Introduction
109
Principle of the Data Transfer
110
Deployment of RS485 Interface for Ptp
110
Parametrization
111
FC/SFC 216 - SER_CFG - Parametrization Ptp
111
Communication
112
FC/SFC 217 - SER_SND - Send to Ptp
112
FC/SFC 218 - SER_RCV - Receive from Ptp
112
Protocols and Procedures
112
Modbus - Function Codes
116
Modbus - Example Communication
121
7 Deployment Ethernet Communication - Productive
123
Basics - Industrial Ethernet in Automation
123
Basics - ISO/OSI Reference Model
124
Basics - Terms
125
Basics - Protocols
126
Basics - IP Address and Subnet
128
Fast Introduction
130
Commissioning and Initialization
131
Hardware Configuration - CPU
132
Configure Siemens S7 Connections
133
Configure Open Communication
139
NCM Diagnostic - Help for Error Diagnostic
142
8 Deployment Ethernet Communication - PROFINET
145
Basics PROFINET
145
PROFINET Installation Guidelines
147
PROFINET System Limits
149
Fast Introduction
150
Commissioning and Initialization
151
Hardware Configuration - CPU
152
Parameters - PROFINET IO Controller
153
Precondition
153
Pn-Io
153
Port 1
154
Configuration PROFINET IO Device
154
Configuration PROFINET-I-Device / Shared-Device
155
Topology - Configuration
157
Device Replacement Without Exchangeable Medium/Pg
158
Replace Device
159
Commissioning and Start-Up Behaviour
159
PROFINET Diagnostics
160
Overview
160
Diagnostics with the Configuration and Engineering Tool
161
Diagnostics During Runtime in the User Program
161
Diagnostics Via ob Start Information
163
Diagnostics Via Status Leds
164
9 Configuration with TIA Portal
165
TIA Portal - Work Environment
165
General
165
Work Environment of the TIA Portal
165
TIA Portal - Hardware Configuration - CPU
166
TIA Portal - Hardware Configuration - I/O Modules
167
Device Overview
167
Module
167
Plc
167
TIA Portal - Hardware Configuration - Ethernet PG/OP Channel
168
Dio
168
TIA Portal - Hardware Configuration - PG/OP Via PROFINET
171
TIA Portal - Setting VIPA Specific CPU Parameters
173
Thus, the VIPA Components Can be Displayed, You
174
Have to Deactivate the "Filter" of the Hardware Catalog
174
TIA Portal - VIPA-Include Library
176
Vipa_Speedbus
176
TIA Portal - Project Transfer
177
VIPA System 300S Manual (182 pages)
Brand:
VIPA
| Category:
Network Hardware
| Size: 3 MB
Table of Contents
Table of Contents
3
About this Manual
5
Safety Information
8
Chapter 1 Basics
9
Safety Information for Users
10
Chapter 1 Basics
10
Operating Structure of a CPU
11
Cpu 317-4Pn12
14
Chapter 2 Assembly and Installation Guidelines
19
Overview
20
Chapter 2 Assembly and Installation Guidelines
20
Installation Dimensions
21
Assembly SPEED-Bus
22
Assembly Standard Bus
26
Cabling
28
Installation Guidelines
29
Chapter 3 Hardware Description
33
Properties
34
Structure
35
Technical Data
41
Chapter 4 Deployment CPU 317-4PN12
47
Assembly
48
Start-Up Behavior
48
Chapter 4 Deployment CPU 317-4PN12
48
Addressing
49
Hardware Configuration - CPU
52
Hardware Configuration - I/O Modules
53
Hardware Configuration - Ethernet PG/OP Channel
54
Hardware Configuration - SPEED-Bus
56
Setting Standard CPU Parameters
61
Setting VIPA Specific CPU Parameters
66
Project Transfer
71
Access to the Internal Web Page
75
Operating Modes
77
Overall Reset
80
Firmware Update
82
Factory Reset
85
Slot for Storage Media
86
Memory Extension with MCC
87
Extended Know-How Protection
88
MMC-CMD - Auto Commands
90
VIPA Specific Diagnostic Entries
92
Using Test Functions for Control and Monitoring of Variables
97
Chapter 5 Deployment Ptp Communication
99
Fast Introduction
100
Principle of the Data Transfer
101
Deployment of RS485 Interface for Ptp
102
Chapter 5 Deployment Ptp Communication
102
Parameterization
105
Communication
108
Protocols and Procedures
114
Modbus - Function Codes
118
Modbus - Example Communication
122
Chapter 6 Deployment PROFIBUS Communication
125
Overview
126
Chapter 6 Deployment PROFIBUS Communication
126
Fast Introduction
127
Hardware Configuration - CPU
128
Deployment as PROFIBUS DP Master
129
Deployment as PROFIBUS DP Slave
130
PROFIBUS Installation Guidelines
132
Commissioning and Start-Up Behavior
135
Chapter 7 Deployment Ethernet Com. - Productive
137
Basics - Industrial Ethernet in Automation
138
Chapter 7 Deployment Ethernet Com. - Productive
138
Basics - ISO/OSI Reference Model
139
Basics - Terms
142
Basics - Protocols
143
Basics - IP Address and Subnet
145
Fast Introduction
147
Commissioning and Initialization
148
Hardware Configuration - CPU
149
Configure Siemens S7 Connections
150
Configure Open Communication
158
NCM Diagnostic - Help for Error Diagnostic
161
Chapter 8 Deployment Ethernet Com. - PROFINET
165
Basics PROFINET
166
Chapter 8 Deployment Ethernet Com. - PROFINET
166
PROFINET Installation Guidelines
168
Basics - IP Address and Subnet
170
Fast Introduction
172
Commissioning and Initialization
173
Hardware Configuration - CPU
174
Parameter - PROFINET IO Controller
175
Configuration PROFINET IO Device
177
Commissioning and Start-Up Behavior
178
PROFINET Diagnostics
180
Advertisement
VIPA System 300S Manual (180 pages)
Brand:
VIPA
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
3
About this Manual
5
Safety Information
8
Chapter 1 Basics
9
Chapter 1 Basics
10
Safety Information for Users
10
Operating Structure of a CPU
11
Cpu 312-5Be13
14
Chapter 2 Assembly and Installation Guidelines
17
Chapter 2 Assembly and Installation Guidelines
18
Installation Dimensions
18
Assembly
19
Cabling
21
Installation Guidelines
23
Chapter 3 Hardware Description
27
Properties
28
Structure
29
In-/Output Range CPU 312-5BE13
34
Technical Data
36
Chapter 4 Deployment CPU 312-5Be13
43
Assembly
44
Chapter 4 Deployment CPU 312-5BE13
44
Start-Up Behavior
44
Addressing
45
Address Assignment
47
Hardware Configuration - CPU
48
Hardware Configuration - I/O Modules
49
Hardware Configuration - Ethernet PG/OP Channel
50
CPU Parameterization
52
Project Transfer
56
Access to the Internal Web Page
59
Operating Modes
60
Overall Reset
63
Firmware Update
65
Factory Reset
68
Slot for Storage Media
69
Memory Extension with MCC
70
Extended Know-How Protection
71
MMC-CMD - Auto Commands
73
VIPA Specific Diagnostic Entries
75
Using Test Functions for Control and Monitoring of Variables
80
Chapter 5 Deployment I\/O Periphery
83
Overview
84
In-/Output Range CPU 312-5BE13
85
Address Assignment
87
Digital Part
88
Digital Part - Parameterization
90
Counter - Fast Introduction
91
Overview
94
Counter - Controlling
96
Counter - Functions
100
Counter - Additional Functions
106
Frequency Measurement
113
Pulse Width Modulation - PWM
118
Diagnostic and Interrupt
124
Chapter 6 Deployment Ptp Communication
133
Fast Introduction
134
Principals of the Data Transfer
135
Deployment RS485 Interface
136
Parameterization
137
Communication
140
Protocols and Procedures
146
Modbus - Function Codes
150
Modbus - Example Communication
154
Chapter 7 Winplc7
157
Winplc7
158
System Presentation
158
Installation
159
Example Project Engineering
160
Chapter 8 Configuration with TIA Portal
170
TIA Portal - Work Environment
170
TIA Portal - Hardware Configuration - CPU
172
TIA Portal - Hardware Configuration - I/O Modules
173
TIA Portal - Hardware Configuration - Ethernet PG/OP Channel
174
TIA Portal - Include VIPA Library
177
TIA Portal - Project Transfer
178
VIPA System 300S Manual (168 pages)
Brand:
VIPA
| Category:
Control Systems
| Size: 2 MB
Table of Contents
Table of Contents
3
About this Manual
5
Safety Information
8
Chapter 1 Basics
9
Safety Information for Users
10
Chapter 1 Basics
10
Operating Structure of a CPU
11
Cpu 315-4Pn12
14
Chapter 2 Assembly and Installation Guidelines
17
Installation Dimensions
18
Chapter 2 Assembly and Installation Guidelines
18
Assembly Standard Bus
19
Cabling
21
Installation Guidelines
22
Chapter 3 Hardware Description
25
Properties
26
Structure
27
Technical Data
33
Chapter 4 Deployment CPU 315-4PN12
39
Assembly
40
Start-Up Behavior
40
Chapter 4 Deployment CPU 315-4PN12
40
Addressing
41
Hardware Configuration - CPU
43
Hardware Configuration - I/O Modules
44
Hardware Configuration - Ethernet PG/OP Channel
45
Setting Standard CPU Parameters
47
Setting VIPA Specific CPU Parameters
52
Project Transfer
57
Access to the Internal Web Page
61
Operating Modes
63
Overall Reset
66
Firmware Update
68
Factory Reset
71
Slot for Storage Media
72
Memory Extension with MCC
73
Extended Know-How Protection
74
MMC-CMD - Auto Commands
76
VIPA Specific Diagnostic Entries
78
Using Test Functions for Control and Monitoring of Variables
83
Chapter 5 Deployment Ptp Communication
85
Fast Introduction
86
Principle of the Data Transfer
87
Deployment of RS485 Interface for Ptp
88
Chapter 5 Deployment Ptp Communication
88
Parameterization
91
Communication
94
Protocols and Procedures
100
Modbus - Function Codes
104
Modbus - Example Communication
108
Chapter 6 Deployment PROFIBUS Communication
111
Overview
112
Chapter 6 Deployment PROFIBUS Communication
112
Fast Introduction
113
Hardware Configuration - CPU
114
Deployment as PROFIBUS DP Master
115
Deployment as PROFIBUS DP Slave
116
PROFIBUS Installation Guidelines
118
Commissioning and Start-Up Behavior
121
Chapter 7 Deployment Ethernet Com. - Productive
123
Basics - Industrial Ethernet in Automation
124
Chapter 7 Deployment Ethernet Com. - Productive
124
Basics - ISO/OSI Reference Model
125
Basics - Terms
128
Basics - Protocols
129
Basics - IP Address and Subnet
131
Fast Introduction
133
Commissioning and Initialization
134
Hardware Configuration - CPU
135
Configure Siemens S7 Connections
136
Configure Open Communication
144
NCM Diagnostic - Help for Error Diagnostic
147
Chapter 8 Deployment Ethernet Com. - PROFINET
151
Basics PROFINET
152
Chapter 8 Deployment Ethernet Com. - PROFINET
152
PROFINET Installation Guidelines
154
Basics - IP Address and Subnet
156
Fast Introduction
158
Commissioning and Initialization
159
Hardware Configuration - CPU
160
Parameter - PROFINET IO Controller
161
Configuration PROFINET IO Device
163
Commissioning and Start-Up Behavior
164
PROFINET Diagnostics
166
VIPA System 300S Manual (148 pages)
Brand:
VIPA
| Category:
Computer Hardware
| Size: 8 MB
Table of Contents
Table of Contents
3
1 General
6
Copyright © VIPA Gmbh
6
About this Manual
7
Safety Information
8
2 Basics
10
Safety Information for Users
10
Operating Structure of a CPU
10
General
10
Applications
11
Operands
11
Cpu 315-2Ag13
12
General Data
14
3 Assembly and Installation Guidelines
17
Installation Dimensions
17
Assembly Standard Bus
18
Cabling
19
Installation Guidelines
22
4 Hardware Description
25
Properties
25
Structure
26
General
26
Interfaces
26
Memory Management
28
Storage Media Slot
28
Battery Backup for Clock and RAM
28
Operating Mode Switch
29
Leds
29
Technical Data
31
5 Deployment CPU 315-2AG13
38
Assembly
38
Start-Up Behavior
38
Addressing
39
Overview
39
Addressing Backplane Bus I/O Devices
39
Hardware Configuration - CPU
40
Hardware Configuration - I/O Modules
41
Hardware Configuration - Ethernet PG/OP Channel
42
Hardware Configuration - Communication
44
Setting Standard CPU Parameters
44
Parametrization Via Siemens CPU
44
Parameters CPU
44
Parameters for DP
47
Parameters for MPI/DP
47
Setting VIPA Specific CPU Parameters
48
Proceeding
48
VIPA Specific Parameters
50
Project Transfer
53
Transfer Via MPI/PROFIBUS
53
Transfer Via Ethernet
55
Transfer Via MMC
56
Access to the Internal Web Page
57
Operating Modes
59
Overview
59
Function Security
61
Overall Reset
61
Firmware Update
63
Reset to Factory Setting
65
Slot for Storage Media
66
Memory Extension with MCC
67
Extended Know-How Protection
68
MMC-CMD - Auto Commands
69
VIPA Specific Diagnostic Entries
71
Control and Monitoring of Variables with Test Functions
87
6 Deployment Ptp Communication
89
Fast Introduction
89
Principle of the Data Transfer
90
Deployment of RS485 Interface for Ptp
90
Parametrization
93
Fc/Sfc 216 - Ser_Cfg
93
Communication
96
Overview
96
Fc/Sfc 217 - Ser_Snd
97
Fc/Sfc 218 - Ser_Rcv
102
Protocols and Procedures
104
Modbus - Function Codes
108
Modbus - Example Communication
113
7 Deployment PROFIBUS Communication
116
Overview
116
Fast Introduction
116
Hardware Configuration - CPU
117
Deployment as PROFIBUS DP Master
118
Deployment as PROFIBUS DP Slave
119
PROFIBUS Installation Guidelines
121
Commissioning and Start-Up Behavior
124
8 Winplc7
126
System Conception
126
Installation
126
Example Project Engineering
128
Job Definition
128
Project Engineering
128
Test the PLC Program in the Simulator
134
Transfer PLC Program to CPU and Its Execution
135
9 Configuration with TIA Portal
137
TIA Portal - Work Environment
137
General
137
Work Environment of the TIA Portal
137
TIA Portal - Hardware Configuration - CPU
138
TIA Portal - Hardware Configuration - I/O Modules
139
TIA Portal - Hardware Configuration - Ethernet PG/OP Channel
140
TIA Portal - Setting VIPA Specific CPU Parameters
143
TIA Portal - Include VIPA Library
145
TIA Portal - Project Transfer
146
VIPA System 300S Manual (165 pages)
SM-AIO
Brand:
VIPA
| Category:
Control Unit
| Size: 6 MB
Table of Contents
Table of Contents
3
1 Basics
5
Copyright © VIPA Gmbh
5
Über dieses Handbuch
6
Safety Information
7
2 Assembly and Installation Guidelines
9
Safety Information for Users
9
Overview
9
Installation Dimensions
10
Assembly SPEED-Bus
12
Assembly Standard Bus
15
Cabling
17
Installation Guidelines
20
General Data I/O Modules
23
General Data
23
3 Analog Input Modules
26
Principles
26
Parameterization - Basics
27
Parameterization by Hardware Configuration
27
Parameterization During Runtime
27
331-1KF01 - AI 8X13Bit
30
331-1KF01 - AI 8X13Bit - Parameterization
34
331-1KF01 - Technical Data
40
331-7Kx01 - AI 8(2)X12Bit
45
Connection of Sensors
48
331-7Kx01 - AI 8(2)X12Bit - Parameterization
53
331-7Kx01 - AI 8(2)X12Bit - Diagnostics
61
331-7KB01 - Technical Data
66
331-7KF01 - Technical Data
73
4 Analog Output Modules
80
General
80
Connecting Loads and Actuators
80
Analog Value Representation
82
Parameterization - Basics
82
Parameterization by Hardware Configuration
82
Parameterization During Run Time by Means of Sfcs
83
Diagnostics
86
332-5HB01 - AO 2/4X12Bit U/I 2-Channel
90
Technical Data
93
332-5HD01 - AO 2/4X12Bit U/I 4-Channel
96
Technical Data
99
332-5HD50 - AO 4X12Bit I for Manual Operation
102
Manual Operation
105
Technical Data
106
332-5HD60 - AO 4X12Bit U for Manual Operation
109
Manual Operation
111
Technical Data
112
5 Analog I/O Modules
115
General
115
Analog Value Representation
115
Parameterization
118
Parameterization by Hardware Configuration
118
Parameterization During Run Time by Means of Sfcs
119
334-0KE00 - AI 4/AO 2X12Bit
120
Technical Data
121
6 Analog I/O Modules FAST - SPEED-Bus
128
General
128
Analog Value Representation
129
Operating Modes
130
Addressing at SPEED-Bus
131
Project Engineering
132
Fast Introduction
132
Preconditions
132
Steps of Project Engineering
133
Parameterization
135
Structure of the Parameter Bytes
136
SFC 193 - Oscilloscope-/FIFO Function
140
Example for the Oscilloscope Function
144
Example for the FIFO Function
146
Diagnostics
150
Process Interrupts
152
331-7AF70 - AI 8X16Bit I
153
Technical Data
156
331-7BF70 - AI 8X16Bit U
159
Technical Data
161
VIPA System 300S Manual (148 pages)
SPEED7 - CPU; 314-2AG13
Brand:
VIPA
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
3
About this Manual
5
System Presentation
5
Safety Information
8
Installation
8
Chapter 1 Basics
9
Chapter 1 Basics
10
Safety Information for Users
10
Operating Structure of a CPU
11
Cpu 314-2Ag13
14
Chapter 2 Assembly and Installation Guidelines
17
Chapter 2 Assembly and Installation Guidelines
18
Installation Dimensions
18
Assembly Standard Bus
19
Cabling
21
Installation Guidelines
22
Chapter 3 Hardware Description
25
Chapter 3 Hardware Description
26
Properties
26
Structure
27
Technical Data
33
Chapter 4 Deployment CPU 314-2AG13
37
Assembly
38
Start-Up Behavior
38
Addressing
39
Hardware Configuration - CPU
41
Hardware Configuration - I/O Modules
42
Hardware Configuration - Ethernet PG/OP Channel
43
Setting Standard CPU Parameters
45
Setting VIPA Specific CPU Parameters
52
Project Transfer
57
Access to the Internal Web Page
61
Operating Modes
63
Overall Reset
66
Firmware Update
68
Factory Reset
71
Slot for Storage Media
72
Memory Extension with MCC
73
Extended Know-How Protection
74
MMC-CMD - Auto Commands
76
VIPA Specific Diagnostic Entries
78
Using Test Functions for Control and Monitoring of Variables
83
Chapter 5 Deployment Ptp Communication
85
Fast Introduction
86
Principle of the Data Transfer
87
Deployment of RS485 Interface for Ptp
88
Parameterization
91
Communication
94
Protocols and Procedures
100
Modbus - Function Codes
104
Modbus - Example Communication
108
Chapter 6 Deployment Profibus Communication
111
Overview
112
Fast Introduction
113
Hardware Configuration - CPU
114
Deployment as PROFIBUS DP Master
115
Deployment as PROFIBUS DP Slave
116
PROFIBUS Installation Guidelines
118
Commissioning and Start-Up Behavior
121
Chapter 7 Winplc7
123
Winplc7
124
System Presentation
124
Installation
125
Example Project Engineering
126
TIA Portal - Work Environment
136
Chapter 8 Configuration with TIA Portal
137
TIA Portal - Hardware Configuration - CPU
138
TIA Portal - Hardware Configuration - I/O Modules
139
TIA Portal - Hardware Configuration - Ethernet PG/OP Channel
140
TIA Portal - Setting VIPA Specific CPU Parameters
143
TIA Portal - Include VIPA Library
146
TIA Portal - Project Transfer
147
VIPA System 300S Manual (122 pages)
SPEED7 - CPU, 314-2BG03
Brand:
VIPA
| Category:
Control Systems
| Size: 3 MB
Table of Contents
Table of Contents
3
About this Manual
5
HB140E - CPU - RE_314-2BG03 - Rev
5
Safety Information
7
Chapter 1 Basics
9
Safety Information for Users
10
General Description of the System 300
11
Operating Structure of a CPU
12
Cpu 314Se/Dps
15
Chapter 2 Assembly and Installation Guidelines
17
Overview
18
Installation Dimensions
19
Assembly Standard-Bus
20
Cabling
21
Installation Guidelines
24
Structure
27
Chapter 3 Hardware Description
27
Components
30
Technical Data
33
Chapter 4 Deployment CPU 314Se/Dps
37
Assembly Standard-Bus
38
Start-Up Behavior
39
Addressing
40
Initialization Ethernet PG/OP Channel
42
Access to the Internal Web Page
45
Project Engineering
46
Setting CPU Parameters
49
Setting Module Parameters
53
Project Transfer
54
Operating Modes
58
Overall Reset
61
Firmware Update
63
Factory Reset
66
Memory Extension with MCC
67
Extended Know-How Protection
68
MMC-CMD - Auto Commands
70
VIPA Specific Diagnostic Entries
72
Using Test Functions for Control and Monitoring of Variables
76
Chapter 5 Deployment Ptp Communication
79
Fast Introduction
80
Principle of the Data Transfer
81
Deployment of RS485 Interface for Ptp
82
Parameterization
84
Communication
87
Protocols and Procedures
93
Modbus - Function Codes
97
Modbus - Example Communication
101
Chapter 6 Deployment Profibus Communication
103
Overview
104
Deployment as Profibus DP Slave
105
Profibus Installation Guidelines
107
Winplc7
112
System Presentation
112
Installation
113
Example Project Engineering
114
Appendix
121
Chapter 7 Winplc7
121
VIPA System 300S Manual (72 pages)
Brand:
VIPA
| Category:
Control Unit
| Size: 3 MB
Table of Contents
Table of Contents
3
1 General
4
Copyright © VIPA Gmbh
4
About this Manual
5
Safety Information
6
2 Basics
8
Safety Information for Users
8
Hints for the Project Engineering
9
General Data
12
3 Assembly and Installation Guidelines
14
Overview
14
Installation Dimensions
15
Assembly SPEED-Bus
16
Installation Guidelines
19
4 Hardware Description
23
Properties
23
Structure
24
Technical Data
26
5 Deployment
28
Basics - Industrial Ethernet in Automation
28
Basics - ISO/OSI Reference Model
29
Basics - Terms
30
Basics - Protocols
31
Basics - IP Address and Subnet
35
Basics - MAC Address and TSAP
37
Fast Introduction
38
Addressing at SPEED-Bus
42
Hardware Configuration
43
Fast Introduction
43
Requirements
44
Steps of Project Engineering
45
Configure Connections
50
Overview
50
Siemens Netpro
51
Connection Type - S7
55
Connection Type - Send/Receive
57
NCM Diagnostic - Help for Error Diagnostic
67
Coupling to Other Systems
69
VIPA System 300S Manual (74 pages)
SPEED7 - CP 342-2IA71
Brand:
VIPA
| Category:
Control Unit
| Size: 2 MB
Table of Contents
Table of Contents
3
HB140E - CP - RE_342-2IA71 - Rev
4
About this Manual
5
Safety Information
7
Chapter 1 Basics
9
Safety Information for Users
10
General Description of the System 300
11
System 300S
12
Basics Interbus
15
Chapter 2 Assembly and Installation Guidelines
19
Overview
20
Installation Dimensions
21
Installation Standard-Bus
22
Assembly SPEED-Bus
23
Cabling
26
Installation Guidelines
30
Chapter 3 Hardware Description
33
Hardware Description
34
Properties
34
Structure
35
Technical Data
38
Chapter 4 Deployment
39
Fast Introduction
40
Addressing at SPEED-Bus
42
Hardware Configuration
43
Register Allocation
47
Interbus Configuration
53
Diagnostics
66
Firmware Update
69
Example
71
Appendix
73
VIPA System 300S Manual (56 pages)
VIPA System 300S SPEED7
Brand:
VIPA
| Category:
Controller
| Size: 1 MB
Table of Contents
Table of Contents
5
User Considerations
7
Safety Information
8
Chapter 1 Basics
9
Chapter 1 Basics
10
Safety Information for Users
10
General Description of the System 300
11
System 300S
12
Hints for the Project Engineering
15
Chapter 2 Assembly and Installation Guidelines
19
Chapter 2 Assembly and Installation Guidelines
20
Overview
20
Installation Dimensions
21
Installation Standard-Bus
22
Assembly SPEED-Bus
23
Cabling
26
Installation Guidelines
30
Chapter 3 Hardware Description
33
Properties
34
Structure
35
Technical Data
38
Chapter 4 Deployment CP 342S-DP
40
Basics Profibus
40
Addressing at SPEED-Bus
41
Project Engineering
42
Slave Operation
48
Advertisement
Related Products
VIPA CPU 315-4PN43
VIPA CP 343-1EX71
VIPA System 300S IM 353-1DP01
VIPA IM 306-1LZ00
VIPA IM 306-1LE00
VIPA 313-6CF03
VIPA System 200V Series
VIPA System SLIO IM 053DN
VIPA System 200V IM Series
VIPA System 200V PS
VIPA Categories
Touch Panel
Control Unit
Control Systems
Controller
Computer Hardware
More VIPA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual