Sign In
Upload
Manuals
Brands
Sutter Instrument Manuals
Controller
MP-285
Sutter Instrument MP-285 Manuals
Manuals and User Guides for Sutter Instrument MP-285. We have
3
Sutter Instrument MP-285 manuals available for free PDF download: Reference Manual, Basic Operations
Sutter Instrument MP-285 Reference Manual (90 pages)
Micromanipulator
Brand:
Sutter Instrument
| Category:
Controller
| Size: 2 MB
Table of Contents
Table of Contents
5
General Information
9
About the Reference Manual
9
Input Devices
11
Rotary Optical Encoder (Roe)
11
Joystick
12
Adjustment of Input Device Characteristics
13
Controller Configuration [Prgm]
14
Continuous Mode Sub-Menu [Prgm\Continuous]
15
For Users of the Rotary Optical Encoder (Roe)
15
For Users of the Joystick
15
Speed Range
16
Offset
17
Jump to Max at
17
Max Speed
18
Pulse Mode Sub-Menu [Prgm\Pulse]
18
Setup Submenu [Prgm\Setup]
19
Axes [PRGM Setup\Axes]
19
New Origin
20
Axis Assignment
20
Fourth (4 Th ) Axis Menu [Prgm\Setup\4 Th Axis]
22
New Setup [PRGM\SETUP\4 Th Axis\New Setup]
23
New Angle [PRGM\SETUP\4 Th Axis\New Angle]
24
How the 4Th Axis Is Defined
24
How to Setup a Diagonal to Provide Coaxial Movement of a Pipette
25
Direction of Movement Along the Diagonal
26
Hardware [Prgm\Setup\Hardware]
26
Dead Zone
27
To Set the Dead Zone Value
27
Utilities [Prgm\Setup \Utilities ]
28
Baud [PRGM Setup\Utilities\Baud]
29
Info [Prgm\Setup\Utilities\Info]
29
SIO Test [Prgm\Setup\Utilities\Sio Test]
30
Reset [Prgm\Setup\Util Ties\Reset]
31
Center Axes [Prgm\Setup\Utilities\Center Axes]
32
AD Test [Prgm\Setup\Utilities\Ad Test]
33
Pause [Prgm\Setup\Util Ties\Pause]
33
Save/Load Menu [Prgm\Save/Load]
34
To Access the Save/Load Menu
34
! View/Load
34
Save /Clear [Prgm\Save /Load \Save /Clear ]
35
Iew /Load ]
35
Movement Screen [Move]
37
Course /Fine Movement Resolution [Move\3] and [Move\6]
38
Continuous/Pulse Movement Modes [MOVE\MOVE]
38
Input Device Response Adjustment [Move\1,2,4 or 5]
38
Adjustment of Parameters Affecting PULSE Movement
38
Adjustment of Parameters Effecting CONTINUOUS Movement (ROE Users)
39
Adjustment of Parameters Effecting Continuous Movement (Joystick Users )
40
Th Axis " or Diagonal Movement [Move\8]
41
Setting Relative Origin [Move\0] and Relative Display Mode [Move\Entr]
41
Robotic Movements [Move\*]
43
General Information
43
Home Functions
44
Home[Move\*\Home]
44
New Home [Move\*\New Home]
44
Show Home [Move\*\Show Home ]
45
Generalized Robotic Movements
45
Execute [Move\*\Execute ]
46
Resuming from a Pause [Move\*\Execute \Resume ]
47
Absolute /Relative Robotic Program Execution [Move\*\Execute \Abs /Rel ]
47
To Toggle between Absolute and Relative Modes of Robotic Program Execution
48
Learn [Move\*\Learn ]
48
Saving , Loading and Viewing Robotic Programs [Move\*\Select Program ]
51
To Use "Save Clear
51
To Use "Load
52
To Use "View
52
Setup Selection [*]
53
To Use the Setup Selection Menu (Select Factory Installed SETUPS by Label)
53
To Rapidly Select any SETUP from the Main Menu
53
Manipulator Installation
55
Mounting the Mp-285: General Considerations
55
Minimizing Noise
55
Mounting the Mp-285: Specifics
56
285210 Mounting Adapter Plate
56
285RBI Rotary Base
57
Mounting Pipette Holders and Headstages
57
Plate - Mounted Devices
58
To Install the CV-4 or EPC-7, 8 or 9 Headstages Onto the Standard Dovetail Mounting Plate
58
Rod -Mounted Devices
59
Adjusting the Rotating Dovetail Base
60
To Set the Detent to a Desired Working Position or Angle
60
Further Information Abou the Brake Set Screw
62
Further Information about the Relationship between the Dovetail Base, the Brake Disc and the Dovetail Set Screw that Secures Them Together
62
Optional Mounting Configurations
62
Horizontal Offset
62
Vertical Offset
63
Mounting the Manipulator Rotated 90° from the Stage Plate
63
Mounting the Mp-285 Elevated at an Angle
64
Reversing Mp-285 Handedness
65
Reversing the Configuration of the X- Axis Slide Assembly and Its Wiring Harness
66
Reversing the Configuration of the Brake Plate
67
Computer Interface/Supplied Software
69
General Information
69
Error Reporting
69
Remote Commands
69
Status Return Data
71
Setting up for Serial Communication
72
Interface Programs
73
The Visual C++ Mp-285 Interface
78
Preface
78
Installing the Visual C++ PC Controller
78
MP-285 PC Controller User Interface
79
Appendix A. Annotated Menu Tree
81
Appendix B. Balancing Input Device Potentiometers
82
Joystick
82
Appendix C. Troubleshooting/Fuse Replacement
84
Troubleshooting
84
Fuse Replacement
86
Repacking the Mp-285 for Shipping
87
Appendix D. Technical Specifications
88
Advertisement
Sutter Instrument MP-285 Basic Operations (40 pages)
Micromanipulator System
Brand:
Sutter Instrument
| Category:
Controller
| Size: 1 MB
Table of Contents
Disclaimer
5
Safety Warnings and Precautions
5
Electrical
5
Avoiding Electrical Shock and Fire-Related Injury
6
Operational
6
Other
7
Handling Micropipettes
7
Table of Contents
9
1 General Information
11
Structure of the MP-285 Documentation Package
11
Technical Support
11
2 Setup
13
Unpacking
13
Figure 2-1. MP-285 Controller (Front Panel)
13
Figure 2-2. Manipulator
13
Figure 2-3. Rotary Optical Encoder (ROE)
13
Initial Setup and Gross Movement
14
Figure 2-4. MP-285 Controller Rear Connections
14
Installation of the MP-285/M Micromanipulator on Your Microscope
16
General Considerations
16
Specifics
16
Figure 2-5. Manipulator Base Dimensions
16
Mounting Headstages
17
Figure 2-6. Headstage Mounting Plate
17
Adjusting the Rotating Dovetail Base
18
Figure 2-7. Mounting the Headstage on the Manipulator's Z-Axis
18
Figure 2-8. Adjusting the Headstage Angle
18
Minimizing Electrical Noise
19
3 Microscopic Manipulation
21
Some Basic Information
21
SETUP Selection
21
Changing Minimal Resolution
22
Table 3-1. Microsteps Per ROE Turn Settings
22
Table 3-2. Microns Per ROE Turn Settings
23
4 Pulse Movement
25
Table 4-1. Microsteps and Microns Per Pulse Settings
26
5 Home Function
27
How to Define a New Home
27
Moving to the New Home
27
Practical Use of the Home Function
27
6 Generalized Robotic Movements
29
Setting Absolute Zero
29
Redefining Home
29
Clearing Program Location #1 for Recording a New Robotic Series
29
Teaching the MP-285 Controller a New Robotic Series
30
Executing the Newly Entered Program
31
Loading a Saved Program
32
7 Diagonal or 4Th Axis Movements
33
8 Roe Response Characteristics
35
Controlling ROE Knob to Manipulator Stepper Motor Axis Assignment
35
Controlling Movement Amount Per ROE Turn
35
Appendix A. Limited Warranty
37
Index
39
Sutter Instrument MP-285 Basic Operations (38 pages)
Micromanipulator System
Brand:
Sutter Instrument
| Category:
Controller
| Size: 0 MB
Table of Contents
Disclaimer
3
Safety Warnings and Precautions
3
Electrical
3
Avoiding Electrical Shock and Fire-Related Injury
3
Electromagnetic Interference
4
Operational
4
Handling Micropipettes
5
Table of Contents
7
1 General Information
9
Structure of the MP-285 Documentation Package
9
Technical Support
9
2 Setup
11
Unpacking
11
Figure 2-1. MP-285 Controller (Front Panel)
11
Figure 2-2. Manipulator
11
Figure 2-3. Rotary Optical Encoder (ROE)
11
Initial Setup and Gross Movement
12
Figure 2-4. MP-285 Controller Rear Connections
12
Installation of the MP-285 Micromanipulator on Your Microscope
14
General Considerations
14
Specifics
14
Figure 2-5. Manipulator Base Dimensions
14
Mounting Headstages
15
Figure 2-6. Headstage Mounting Plate
15
Adjusting the Rotating Dovetail Base
16
Figure 2-7. Mounting the Headstage on the Manipulator's Z-Axis
16
Figure 2-8. Adjusting the Headstage Angle
16
Minimizing Electrical Noise
17
3 Microscopic Manipulation
19
Some Basic Information
19
SETUP Selection
19
Changing Minimal Resolution
20
Table 3-1. Microsteps Per ROE Turn Settings
20
Table 3-2. Microns Per ROE Turn Settings
21
4 Pulse Movement
23
Table 4-1. Microsteps and Microns Per Pulse Settings
24
5 Home Function
25
How to Define a New Home
25
Moving to the New Home
25
Practical Use of the Home Function
25
6 Generalized Robotic Movements
27
Setting Absolute Zero
27
Redefining Home
27
Clearing Program Location #1 for Recording a New Robotic Series
27
Teaching the MP-285 Controller a New Robotic Series
28
Executing the Newly Entered Program
29
Loading a Saved Program
30
7 Diagonal or 4Th Axis Movements
31
8 Roe Response Characteristics
33
Controlling ROE Knob to Manipulator Stepper Motor Axis Assignment
33
Controlling Movement Amount Per ROE Turn
33
Appendix A. Limited Warranty
35
Index
37
Advertisement
Advertisement
Related Products
Sutter Instrument MP-285A
Sutter Instrument TRIO MP-235
Sutter Instrument MP-225
Sutter Instrument TRIO MP-245A
Sutter Instrument TRIO MP-245
Sutter Instrument MP-225A
Sutter Instrument MPC-325-2
Sutter Instrument MPC-325-4
Sutter Instrument MPC-365 Series
Sutter Instrument MPC-325-3
Sutter Instrument Categories
Laboratory Equipment
Amplifier
Control Systems
Controller
Work Light
More Sutter Instrument Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL