Manuals and User Guides for SciCan STATIM 2000S Cassette Autoclave. We have
4
SciCan STATIM 2000S Cassette Autoclave manuals available for free PDF download: Service Manual, Operator's Manual
SciCan STATIM 2000S Service Manual (275 pages)
Brand:
SciCan
| Category:
Laboratory Equipment
| Size: 8 MB
Table of Contents
Table of Contents
3
STAT IM 2000 / 2000S / 2000 G4 Service Manual
4
About this Service Guide
7
Safety Compliance
7
1 Identifying STATIM 2000 Units
9
Identifying Software Versions
9
Identifying Controller Board Types
11
Identifying Steam Generator Types
12
2 Tools, Maintenance Schedules, Procedures and Testing
15
Tools
15
The Control Box
17
Calibration Cassettes and Reference Meters
18
Calibration Cassettes
18
Reference Meters
19
Annual Service Requirements
33
Routine Maintenance Schedule and Procedures
36
Draining the Reservoir
37
Cleaning the Cassette
37
Cleaning the Water Reservoir Filter
38
Cleaning the Water Reservoir
38
Filters on the STATIM 2000/2000S
38
Bacteria Retentive Filter
39
Compressor Filter
39
Filters on the STATIM 5000/5000S
39
Compressor Filter
40
Replacing the Cassette Seal
41
Cleaning the Cover
42
Shipping the Unit
42
Upgrading the Firmware on STATIM G4 Units
43
Using the STATIM G4 Remote Access Function
44
Electrical Safety Testing
46
Dielectric Strength Test (Hi-Pot)
46
Protective Bonding Impedance Test (Ground Continuity)
46
Water Conductivity Testing
47
3 Diagnostics and Troubleshooting Cycle Faults
49
Basic Mechanical Diagnostics
49
Using Software as a Diagnostic Tool
49
For Units with 2.X/5.X, 6.X Controllers
49
For Units with 7.X Controllers (with Service Menu)
50
(Rev. 7 Controller Board)
50
Troubleshooting Cycle Faults
67
For Revision 3.X and 4.X Controllers
68
Cycle Fault Numbers and Descriptions
69
Cycle Fault Numbers and Descriptions on Units with Revision 2.X/5.X/6.X and 7.X Type Controller Boards
69
4 STATIM 2000 Calibration
83
Calibration Procedure 1: for Rev 3.X or 4.X Boards
83
Control Box
83
Digital Voltmeter
83
Calibration Cassette
84
Digital Voltmeter
84
Calibration Procedure 2: for Rev. 2.X or 5.X Boards, Software R1.XX or R2.XX
87
Calibration Procedure 3: for Rev. 6.X Board
91
Software Rev. 4.XX and 5.XX
91
Calibration Procedure 4: for Rev. 7.X Board, Software Rev. 6.XX
95
Calibration Procedure 8: for Non-S G4 Units with Rev. 7.X Board, Software Rev. 7.XX, SL 00R1.XX
99
5 STATIM 2000S Calibration
105
Calibration Procedure 5: for Rev. 2.X or 5.X Boards,Software R1.XX and R2.XX
105
Digital Reference Thermometer
106
Control Box
106
To Controller Board Header P3)
106
Calibration Procedure 6: for Rev 6.X Boards
110
Software R4.XX and R5.XX
110
To Controller Board Header P4)
111
Controller Board Leader P1)
111
Figure 2
111
Calibration Procedure 7: for Rev 7.X Boards
115
Software R6.XX
115
Calibration Procedure 9: for S-Class G4 Units with Rev. 7.X Board,Software Rev. 7.XX, SL 00R1.XX
120
6 Cover Assembly
125
For STATIM 2000 Classic
125
Removing the Cover
125
Reinstalling the Cover
127
Removing and Replacing the Armature Gasket
128
Removing and Replacing the Fascia
128
Removing and Replacing the Membrane Keypad
128
Removing and Replacing the LCD
131
For STATIM 2000 G4
133
Removing the Cover
133
Reinstalling the Cover
135
Removing and Replacing the Armature Gasket
136
Removing and Replacing the LCD Overlay
137
Removing and Replacing the LCD Touchscreen
138
Removing and Replacing the Fascia
140
7 Electrical and Electronic Components
143
Controller Board
143
Identifying the Controller Board Type
143
Removing the Controller Board Assembly
145
Replacing/Refitting the Controller Board Assembly
148
Controller Board Fuse Values
150
STAT IM 2000 G4 Electronics
151
Removing and Replacing the STAT IM 2000 G4 LCD Controller Board
151
Removing and Replacing the STAT IM 2000 G4 USB Port
153
Speaker
153
Ethernet Port
154
Microprocessor
155
Processor Types
155
Removing the Microprocessor
156
Replacing/Refitting the Microprocessor
157
Microswitch
158
Removing the Microswitch
158
Replacing the Microswitch
159
Adjusting the Microswitch
159
Mains Components
160
Removing and Replacing a Fixed Power Cord
161
Removing a Detachable Power Cord
162
Replacing/Refitting a Detachable Power Cord
162
Power (On/Off) Switch
163
Removing the Power Switch
163
Replacing/Refitting the A.C. Power Switch
164
Receptacle / Line Filter
165
Removing the Receptacle / Line Filter
165
Replacing/Refitting the Receptacle / Line Filter
165
LCD DC Power Source for STAT IM 2000 G4
167
Removing and Replacing the STAT IM 2000 G4
167
LCD DC Power Source
167
8 Pumps, Reservoir and Compressor
169
Water Pumps
169
Identifying Pump Types
169
Testing Pump Flow
170
Water Pump Recovery Repair Procedure
172
Performing Filter Maintenance
172
Performing Internal Pump Filter Maintenance
173
Performing Water Reservoir Filter Maintenance
175
Performing Inline Filter Maintenance
176
Performing Pump Tube Replacement
176
Removing the Fluid-O-Tech Pump Assembly
179
Testing the Fluid-O-Tech Pump Diode
180
Reinstalling the Fluid-O-Tech Pump Assembly
181
Removing the Scican or Ulka Pump Assembly
182
Reinstalling the Scican or Ulka Pump Assembly
182
Reservoir and Water Sensors
183
Removing the Reservoir
183
Reinstalling the Reservoir
184
Troubleshooting
185
Compressor
191
Removing the Compressor
192
Reinstalling the Compressor
193
9 Solenoid Valve and Pressure Transducer
195
Solenoid Valve
195
Inspecting and Repairing the Type B Solenoid Valve
195
Removing the Solenoid Valve
198
Refitting the Solenoid Valve
198
Pressure Transducer
199
Identifying and Checking the Pressure Transducer
199
Removing the Pressure Transducer
203
Reinstalling the Pressure Transducer
204
Removing the Pressure Interface Board
205
Reinstalling the Pressure Interface Board
205
Removing and Replacing the
207
Pressure Interface Board Battery
207
10 Armature, Isoplate, and Probe Bracket and Chamber Thermocouple
209
Armature and Isoplate
209
Removing Armature and Isoplate
209
Reinstalling Armature and Isoplate
211
Removing the Isoplate from the Armature-Isoplate
212
Replacing and Reassembling the Isoplate into the Armature
213
Probe Bracket and Chamber Thermocouple
214
Removing the Probe Bracket and Chamber Thermocouple
214
Replacing and Reinstalling the Probe Bracket and Chamber Thermocouple
217
Aligning the Probe Bracket and Chamber Thermocouple
220
11 Steam Generator, Check Valve, Thermal Fuse and Pressure Relief Valve
223
Steam Generators
223
Replacing 1St Generation and
224
Stainless Steel Steam Generators (Matrix)
224
Removing the Aluminum Steam Generator
225
Reinstalling the Aluminum Steam Generator
226
Removing the Stainless Steel Steam Generator
228
Reinstalling the Stainless Steel Steam Generator
229
Check Valves
231
Testing the Check Valve
231
Removing and Replacing the Check Valve
232
Steam Generator Thermal Fuses
234
Removing the Thermal Fuse
235
On the Aluminum Steam Generator
235
Replacing the Thermal Fuse on the Aluminum Steam Generator
237
Removing and Replacing the Thermal Fuse on the Stainless Steel Steam Generator
238
Pressure Relief Valve
238
Checking the Pressure Relief Valve
239
Removing and Replacing the Pressure Relief Valve
239
12 Printer and Data Logger
243
Printer
243
Removing and Replacing the Statprinter Cover
243
Removing and Replacing the Printer Module
244
Printer Interface Board
245
Removing and Replacing the Battery
245
Adjusting Print Quality
245
Removing and Replacing the Printer Interface Board
245
Removing the Printer Assembly
246
Replacing the Printer
247
Installing Thermal Paper into the Statprinter
248
Removing Paper Jams
249
Recommended Printers
250
Installing the External Printer
251
Data Logger
252
Installing the Scican Data Logger
253
Data Logger Troubleshooting
256
Transferring Data from the USB Drive or SD Card
258
Data Logger Specifications
259
13 Installation
261
Environmental Considerations
261
Unit Placement
262
Connecting the Waste Bottle
262
Filling the STATIM Reservoir
263
Priming the STATIM Pump
263
Powering up and Setting up the Unit
263
Setting the Time and Date
264
Language Selection
264
Assigning Unit Identifier Number
264
Setting/Editing Serial Number
265
Setting Air Drying Time
266
Connecting STAT IM G4 to a Network
267
Setting up the G4 Web Portal
268
Preparing Unit for Use
273
Shipping the Unit
273
Unit Installation Checklist
273
14 STATIM Operational Diagram
275
Advertisement
SciCan STATIM 2000S Operator's Manual (177 pages)
CASSETTE AUTOCLAVE
Brand:
SciCan
| Category:
Laboratory Equipment
| Size: 5 MB
Table of Contents
English
2
Table of Contents
2
1 Introduction
3
2 Important Information
4
Disclaimers
4
Statim 2000S - Unit Overview
5
Statim 5000S - Unit Overview
6
3 Installation
7
Environmental Considerations
7
Unit Placement
7
Connecting the Waste Bottle
8
Filling the Reservoir
8
Priming the Statim Pump
9
Setting the Time and Date
9
Language Selection
10
Assigning Unit Identifier Number
10
Shipping the Unit
10
4 Instructions for Use
11
Statim 5000S - Cassette
12
Statim 5000S - STAT-DRI Plates
13
Preparing and Loading Instruments
13
Selecting a Cycle
16
Running a Cycle
19
Stopping a Cycle
20
5 Maintenance
21
Cleaning the Cassette
21
Cleaning the Water Reservoir Filter
21
Cleaning the Reservoir
21
Cleaning the Exterior Surfaces
21
Changing the Statim 2000S Air Filter
21
Changing the Bacteria Retentive Air Filters
22
Replacing the Cassette Seal
22
Maintaining Fluid Levels
23
Reading Water Quality
23
Preventative Maintenance Schedule
24
6 The Communication Port
25
The RS232 Communication Port
25
Installing Paper on the Internal Printer
29
Removing Internal Printer Paper Jams
31
7 Troubleshooting
35
8 Spare Parts List
39
9 Warranty
40
10 Test Protocol
41
Type Test
41
11 Specifications
43
Statim 2000S - Specifications
43
Statim 5000S - Specifications
44
12 Declaration of Conformity
45
Scican Gmbh
45
Français
46
1 Introduction
47
2 Informations Importantes
48
Avertissements
48
Statim 2000S - Vue D'ensemble de L'appareil
49
Statim 5000S - Vue D'ensemble de L'appareil
50
3 Installation
51
Considérations Environnementales
51
Mise en Place de L'appareil
51
Branchement de la Bouteille À Eau Résiduaire
52
Remplissage du Réservoir
52
Amorçage de la Pompe Statim
53
Réglage de la Date Et de L'heure
53
Sélection de la Langue
54
Attribution du Numéro D'identification de L'appareil
54
Expédition de L'appareil
54
4 Instructions D'utilisation
55
Statim 2000S - Cassette
55
Statim 5000S - Cassette
56
Statim 5000S - Plaques STAT-DRI
57
Préparation Et Chargement des Instruments
57
Guide des Poids des Instruments
59
Sélection D'un Cycle
60
Exécution D'un Cycle
63
Interruption D'un Cycle
64
5 Entretien
65
Nettoyage de la Cassette
65
Nettoyage du Filtre du Réservoir D'eau
65
Nettoyage du Réservoir
65
Nettoyage des Surfaces Extérieures
65
Changement des Filtres À Air Statim 2000S
65
Changement des Filtres À Air Retenant Les Bactéries
66
Remplacement du Joint de Cassette
66
Maintien des Niveaux des Liquides
67
Mesure de la Qualité de L'eau
67
Calendrier D'entretien Préventif
68
6 Le Port de Communication
69
Le Port de Communication RS232
69
Installation de L'enregistreur de Données
70
Installation du Papier Dans L'imprimante Interne
73
Élimination des Bourrages du Papier de L'imprimante Interne
75
7 Dépannage
79
Liste des Pièces de Rechange
83
9 Garantie
84
10 Protocole D'essai
85
Test de Type
85
11 Spécifications
87
Statim 2000S - Spécifications
87
Statim 5000S - Spécifications
88
12 Déclaration de Conformité
89
Scican Gmbh
89
Au Canada : 1-800-870-7777
90
Scican Gmbh Wangener Strasse
90
88299 Leutkirch
90
Tel.: +49 (0)7561 98343
90
Fax: +49 (0)7561 98343
90
Scican Inc
90
Technology Drive
90
Scican Gmbh
133
Scican Gmbh
177
SciCan STATIM 2000S Operator's Manual (48 pages)
Cassette autoclave
Brand:
SciCan
| Category:
Laboratory Equipment
| Size: 0 MB
Table of Contents
Table of Contents
2
1 Introduction
3
2 Important Information
4
Disclaimers
4
Statim 2000 - Unit Overview
5
Statim 5000 - Unit Overview
6
3 Installation
7
Environmental Considerations
7
Unit Placement
7
Connecting the Waste Bottle
8
Filling the Reservoir
8
Priming the Statim Pump
9
Setting the Time and Date
9
Language Selection
10
Assigning Unit Identifier Number
10
Preparing the Unit for Use
10
Shipping the Unit
10
4 Instructions for Use
11
Statim 5000 - Cassette
12
Statim 5000 - STAT-DRI Plates
13
Preparing and Loading Instruments
13
Using Biological/Chemical Indicators
15
Statim 2000 - Selecting a Cycle
17
Statim 2000 - Running a Cycle
20
Statim 5000 - Selecting a Cycle
22
Statim 5000 - Running a Cycle
25
Stopping a Cycle
27
5 Maintenance
28
Cleaning the Cassette
28
Cleaning the Water Reservoir Filter
28
Cleaning the Reservoir
28
Cleaning the Exterior Surfaces
28
Changing the Statim 2000 Air Filter
28
Changing the Bacteria Retentive Air Filters
29
Replacing the Cassette Seal
29
Maintaining Fluid Levels
30
Reading Water Quality
30
Preventative Maintenance Schedule
31
6 The Communication Port
32
The RS232 Communication Port
32
Cycle Printout Overview
36
7 Internal Printer
37
Installing Paper on the Internal Printer
37
Removing Internal Printer Paper Jams
39
8 Troubleshooting
41
9 Spare Parts List
45
10 Warranty
46
11 Specifications
47
Statim 2000 - Specifications
47
Statim 5000 - Specifications
48
Advertisement
SciCan STATIM 2000S Service Manual (59 pages)
Brand:
SciCan
| Category:
Cassette Player
| Size: 2 MB
Table of Contents
Table of Contents
17
1 User Setup Menu
18
Time/Date Setup Mode
18
Language Setup
19
Unit ID Setup
19
Water Quality
20
Last Printout
20
End of Line CR/LF
21
Serial Port Bit Rate
22
Printer User ° Char
22
Save and Exit
22
Exit
22
2 Service Menu
23
Calibration
24
Set Cycle Counter
26
Lock Cycles
26
Conductivity Setup
27
Water.cnd Tmp. Comp
28
Stored CF Printouts
28
Clear CF Printouts
28
Display Last CF
29
Devices Test On/Off
29
Temperature Offset
29
Press. Atm. Offset
30
Press. Ster. Offset
30
Press. Sensor Type
30
Validation Offset
31
Voltage Calibration
31
Voltage Setup
31
Repeater Mode
32
Factory Default
32
Change Password
32
Backup NVRAM
33
Restore NVRAM
33
Advertisement
Related Products
SciCan statim 2000 G4
SciCan BRAVO 21V
SciCan Statim 2000
SciCan statim 5000 G4
SciCan STATIM 7000
SciCan Statim 2000 Cassette Autoclave
SciCan Statim 5000 Cassette Autoclave
SciCan STATIM
SciCan STATIM 900J
SciCan Statim 5000
SciCan Categories
Laboratory Equipment
Washer
Medical Equipment
Dental equipment
Dishwasher
More SciCan Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL