Sign In
Upload
Manuals
Brands
HIMA Manuals
Control Unit
HIMatrix F2 DO 16 01
HIMA HIMatrix F2 DO 16 01 Manuals
Manuals and User Guides for HIMA HIMatrix F2 DO 16 01. We have
5
HIMA HIMatrix F2 DO 16 01 manuals available for free PDF download: Engineering Manual, Manual, Product Description
HIMA HIMatrix F2 DO 16 01 Engineering Manual (64 pages)
HIMatrix System Automation Devices
Brand:
HIMA
| Category:
Control Unit
| Size: 1 MB
Table of Contents
About this Manual
3
Terminology
5
Table of Contents
8
1 Certification
10
2 Notes for Danger and Use
11
Notes for Danger
11
Notes for Use
11
3 Installation of Himatrix Devices
12
Mechanical
12
Installation of Controllers
12
Installation
12
Cable Routing
12
Air Circulation
14
Assembly Heights
16
Pluggable Cable Dimensions
16
Heat Contemplation
16
Heat Dissipation
17
Definitions
17
Installation Type
17
Internal Convection
17
Temperature State/Operating Temperature
18
Standard
18
Operating Voltage
18
Earth and Shield
19
Earthing the System Voltage 24 VDC
19
Non-Earthed Operation
19
Earthed Operation
19
Earth Connections
19
Shields
19
EMC Protection
20
ESD Protection
20
4 Configuring the Hardware
21
Supply Voltage
21
De-Energize to Trip Mode / Energize to Trip Mode
21
Short-Circuit Characteristics of the Output Channels
22
Using the F35 Controller in the Zone
23
Atex)
23
Use in Central Fire Alarm Systems
24
5 Communication
26
Communication Protocols at Himatrix Systems
26
Field Bus Interfaces of the Controller
27
Ethernet Communication
28
Communication Via Switches
28
Safeethernet
28
Ethernet/Ip
29
TCP S/R (Send/Receive over TCP)
29
Sntp
30
Modbus TCP
30
Operating Parameters of the Ethernet Interfaces
30
Configuration of the Ethernet Interfaces
31
Connections for Safeethernet, Ethernet/Networking Example
33
Field Bus Communication
34
Restrictions for Simultaneous Operation of Protocols
34
Mounting of HIMA Field Bus Communication Modules
35
System Requirements
35
Display of the Actual Versions of the Operating Systems
35
Wiring
36
Safeethernet, Ethernet
36
Interface Elements
37
Specified Cables
37
RJ 45 Connector
38
Switches
40
Field Buses
41
Fundamentals of RS-485 Transfer Mode System
41
Profibus Dp
41
MODBUS Master/Slave Communication
42
Interbus
43
6 Labeling
43
Equipment Identification
43
7 Configuration of the Software
44
Supported Data Types
44
Line Monitoring
44
Required Signals
45
Configuration for Pulsed Outputs
46
Configuration Example
47
Principle Method of Signal Assignment
47
Configuring the Pulsed Outputs and Assignment to the Inputs45
47
Assignment of the Signals to the Inputs and Their Error Codes46
48
Activation of the Pulsed Outputs
48
Line Monitoring at Himatrix F35
48
Line Monitoring at F3 DIO 16/8 01
53
Parameterization of Line Monitoring at 2-Pole Connection
53
Line Monitoring for Lamp Loads and Inductive Loads
55
Line Monitoring with Reduced Voltage for Resistive, Capacitive Loads
56
2-Pole Connection with Common Reference Pole (3-Pole Connection)
56
Table of Configurations for Digital Outputs
57
8 Commissioning, Maintenance, Repairs
58
Testing the Inputs and Outputs for Interference Voltage and Earth Faults
58
Modifications
58
Replacement of Modules
59
Maintenance
59
Replacement of Back-Up Batteries
59
Repair of Controllers and Modules
60
Supply of Internal Documentation
60
9 Operating Conditions
61
Climatic Conditions
61
Mechanical Conditions
62
EMC Conditions
62
Voltage Supply
63
Advertisement
HIMA HIMatrix F2 DO 16 01 Manual (42 pages)
Safety-Related Controller
Brand:
HIMA
| Category:
Temperature Controller
| Size: 0 MB
Table of Contents
Certified Himatrix F2
2
Table of Contents F2
2
Table of Contents
3
Introduction
5
Structure and Use of this Manual
5
Table 1: Programming Tools for Himatrix Remote I/Os
5
Target Audience
6
Formatting Conventions
7
Safety Notes
7
Operating Tips
8
Safety
9
Intended Use
9
Environmental Requirements
9
ESD Protective Measures
9
Table 3: Environmental Requirements
9
Residual Risk
10
Safety Precautions
10
Emergency Information
10
Product Description
11
Safety Function
11
Equipment, Scope of Delivery
12
IP Address and System ID (SRS)
12
Type Label
13
Figure 1: Sample Type Label
13
Structure
14
Figure 2: Front View
14
Figure 3: Block Diagram
14
Safety-Related Relay Outputs
15
Burner Control Applications
15
General Safety Applications
16
Figure 4: Contact Lifetime AC
16
LED Indicators
17
Operating Voltage LED
17
System Leds
17
Table 5: Operating Voltage LED
17
Table 6: System Leds
17
Communication Leds
18
I/O Leds
18
Table 7: Ethernet Indicators
18
Table 8: I/O Leds
18
Communication
19
Connections for Ethernet Communication
19
Network Ports Used for Ethernet Communication
19
Figure 5: Sample MAC Address Label
19
Table 9: Ethernet Interfaces Properties
19
Table 10: Network Ports in Use
19
Reset Key
20
Product Data
21
Table 11: Product Data
21
Table 12: Specifications for the Relay Outputs
22
Table 13: Relays Output Switching Capacity
22
Table 14: Certificates
23
Start-Up
24
Installation and Mounting
24
Connecting the Digital Outputs
24
Cable Plugs
25
Table 15: Terminal Assignment for the Relay Outputs
25
Table 16: Power Supply Cable Plug Properties
25
Table 17: Input and Output Cable Plug Properties
25
Mounting the F2 DO 16 02 in Zone 2
26
Figure 6: Label for Ex Conditions
26
Configuration
27
Configuring the Remote I/O with Silworx
27
Parameters and Error Codes for the Output
27
Digital Outputs for F2 DO 16 02
27
Tab Module
28
Table 18: Silworx - System Parameters for Digital Outputs, Module Tab
28
Tab DO 16: Channels
29
Table 19: Silworx - System Parameters for Digital Outputs, DO 16: Channels Tab
29
Configuring the Module with ELOP II Factory
30
Configuring the Outputs
30
Signals and Error Codes for the Output
30
Digital Outputs for F2 DO 16 02
31
Table 20: ELOP II Factory - Digital Output System Signals
31
Operation
32
Handling
32
Diagnosis
32
Maintenance
33
Faults
33
Maintenance Measures
33
Loading the Operating System
33
Proof Test
33
Decommissioning
34
Transport
35
Disposal
36
Appendix
37
Glossary
37
Index of Figures
38
Index of Tables
39
Index
40
HIMA HIMatrix F2 DO 16 01 Manual (40 pages)
Safety-Related Controller
Brand:
HIMA
| Category:
Controller
| Size: 0 MB
Table of Contents
Table of Contents F2
1
Table of Contents
3
Introduction
5
Structure and Use of this Manual
5
Table 1: Programming Tools for Himatrix Remote I/Os
5
Target Audience
6
Formatting Conventions
7
Safety Notes
7
Operating Tips
8
Safety
9
Intended Use
9
Environmental Requirements
9
ESD Protective Measures
9
Table 3: Environmental Requirements
9
Residual Risk
10
Safety Precautions
10
Emergency Information
10
Product Description
11
Safety Function
11
Safety-Related Digital Outputs
11
Figure 1: Connection of Actuators to Outputs
11
Reaction in the Event of a Fault
12
Equipment, Scope of Delivery
13
IP Address and System ID (SRS)
13
Type Label
14
Figure 2: Sample Type Label
14
Assembly
15
Figure 3: Front View
15
Figure 4: Block Diagram
15
LED Indicators
16
Operating Voltage LED
16
System Leds
16
Table 5: Operating Voltage LED
16
Table 6: System Leds
16
Communication Leds
17
I/O Leds
17
Table 7: Ethernet Indicators
17
Table 8: I/O Leds
17
Communication
18
Connections for Ethernet Communication
18
Network Ports Used for Ethernet Communication
18
Figure 5: Sample MAC Address Label
18
Table 9: Ethernet Interfaces Properties
18
Table 10: Network Ports in Use
18
Reset Key
19
Product Data
20
Table 11: Product Data
20
Table 12: Specifications for the Digital Outputs
20
Product Data F2 DO 16 014
21
Certified Himatrix F2 DO 16 01
21
Table 13: Product Data F2 DO 16 014
21
Table 14: Certified Himatrix F2 DO 16 01
21
Start-Up
22
Installation and Mounting
22
Connecting the Digital Outputs
22
Table 15: Terminal Assignment for the Digital Outputs
22
Connecting the Operating Voltage
23
Cable Plugs
23
Table 16: Connecting the Operating Voltage
23
Table 17: Power Supply Cable Plug Properties
23
Table 18: Input and Output Cable Plug Properties
23
Mounting the F2 DO 16 01 in Zone 2
24
Figure 6: Label for Ex Conditions
24
Configuration
25
Configuration with Silworx
25
Parameters and Error Codes for the Output
25
Digital Outputs for F2 DO 16 01
25
Tab Module
26
Table 19: Silworx - System Parameters for Digital Outputs, Module Tab
26
Tab DO 16: Channels
27
Configuration with ELOP II Factory
27
Configuring the Outputs
27
Signals and Error Codes for the Output
27
Table 20: Silworx - System Parameters for Digital Outputs, DO 16: Channels Tab
27
Digital Outputs for F2 DO 16 01
28
Table 21: ELOP II Factory - Digital Output System Signals
28
Operation
29
Handling
29
Diagnosis
29
Maintenance
30
Faults
30
Maintenance Measures
30
Loading the Operating System
30
Proof Test
30
Decommissioning
31
Transport
32
Disposal
33
Appendix
35
Glossary
35
Index of Figures
36
Index of Tables
37
Index
38
Advertisement
HIMA HIMatrix F2 DO 16 01 Product Description (40 pages)
Brand:
HIMA
| Category:
Controller
| Size: 1 MB
Table of Contents
Table of Contents
3
Introduction
5
Structure and Use of this Manual
5
Table 1: Himatrix System Variants
5
Target Audience
6
Table 2: Additional Relevant Documents
6
Formatting Conventions
7
Safety Notes
7
Operating Tips
8
Safety
9
Intended Use
9
Environmental Requirements
9
ESD Protective Measures
9
Table 3: Environmental Requirements
9
Residual Risk
10
Safety Precautions
10
Emergency Information
10
Product Description
11
Safety Function
11
Safety-Related Digital Outputs
11
Figure 1: Connection of Actuators to Outputs
11
Reaction in the Event of a Fault
12
Equipment, Scope of Delivery
13
IP Address and System ID (SRS)
13
Type Label
13
Table 4: Part Numbers
13
Assembly
14
Figure 3: Front View
14
Figure 4: Block Diagram
14
LED Indicators
15
Operating Voltage LED
15
Table 5: Operating Voltage LED
15
System Leds
16
Table 6: System Leds
16
Communication Leds
17
I/O Leds
17
Table 7: Ethernet Indicators
17
Table 8: I/O Leds
17
Communication
18
Connections for Ethernet Communication
18
Network Ports Used for Ethernet Communication
18
Figure 5: Sample MAC Address Label
18
Table 9: Ethernet Interfaces Properties
18
Table 10: Network Ports in Use
18
Reset Key
19
Product Data
20
Table 11: Product Data
20
Table 12: Specifications for the Digital Outputs
20
Certified Himatrix F2 DO 16 01
21
Table 13: Certified Himatrix F2
21
Start-Up
22
Installation and Mounting
22
Connecting the Digital Outputs
22
Table 14: Terminal Assignment for the Digital Outputs
22
Connecting the Operating Voltage
23
Table 15: Connecting the Operating Voltage
23
Mounting the F2 DO 16 01 in Zone 2
24
Figure 6: Label for Ex Conditions
24
Configuration
25
Configuring a Remote I/O with Silworx
25
Parameters and Error Codes for the Output
25
Digital Outputs for F2 DO 16 01
25
Module Tab
26
Table 16: Silworx - System Parameters for Digital Outputs, Module Tab
26
DO 16: Channels Tab
27
Configuring a Resource Using ELOP II Factory
27
Configuring the Outputs
27
Signals and Error Codes for the Output
27
Table 17: Silworx - System Parameters for Digital Outputs, DO 16: Channels Tab
27
Digital Outputs for F2 DO 16 01
28
Table 18: ELOP II Factory - Digital Output System Signals
28
Operation
29
Handling
29
Diagnosis
29
Maintenance
30
Faults
30
Operating System Version 6.42 and Beyond
30
Operating System Versions Prior to 6.42
30
Maintenance Measures
30
Loading the Operating System
30
Proof Test
30
Decommissioning
31
Transport
32
Disposal
33
Appendix
35
Glossary
35
Index of Figures
36
Index of Tables
37
Index
38
HIMA HIMatrix F2 DO 16 01 Manual (40 pages)
Safety-Related Controller
Brand:
HIMA
| Category:
Controller
| Size: 0 MB
Table of Contents
Table of Contents
3
1 Introduction
5
Structure and Use of this Manual
5
Table 1: Himatrix System Variants
5
Target Audience
6
Table 2: Additional Relevant Documents
6
Formatting Conventions
7
Safety Notes
7
Operating Tips
8
2 Safety
9
Intended Use
9
Environmental Requirements
9
ESD Protective Measures
9
Table 3: Environmental Requirements
9
Residual Risk
10
Safety Precautions
10
Emergency Information
10
3 Product Description
11
Safety Function
11
Safety-Related Digital Outputs
11
Reaction in the Event of a Fault
12
Equipment, Scope of Delivery
13
IP Address and System ID (SRS)
13
Type Label
13
Table 4: Part Numbers
13
Assembly
14
Figure 2: Front View
14
Figure 3: Block Diagram
14
LED Indicators
15
Operating Voltage LED
15
Table 5: Operating Voltage LED
15
System Leds
16
Table 6: System Leds
16
Communication Leds
17
I/O Leds
17
Table 7: Ethernet Indicators
17
Table 8: I/O Leds
17
Communication
18
Connections for Ethernet Communication
18
Network Ports Used for Ethernet Communication
18
Figure 4: Sample MAC Address Label
18
Table 9: Ethernet Interfaces Properties
18
Table 10: Network Ports in Use
18
Reset Key
19
Product Data
20
Table 11: Product Data
20
Table 12: Specifications for the Relay Outputs
20
Certified Himatrix F2 DO 16 02
21
Table 13: Certificates
21
4 Start-Up
22
Installation and Mounting
22
Connecting the Digital Outputs
22
Table 14: Terminal Assignment for the Relay Outputs
23
Mounting the F2 DO 16 02 in Zone 2
24
Figure 5: Label for Ex Conditions
24
Configuration
25
Configuration with Silworx
25
Parameters and Error Codes for the Output
25
Digital Outputs for F2 DO 16 02
25
Module Tab
26
Table 15: Silworx - System Parameters for the Digital Outputs, Module Tab
26
DO 16: Channels Tab
27
Table 16: Silworx - System Parameters for the Digital Outputs, DO 16: Channels Tab
27
Configuring a Controller Using ELOP II Factory
28
Configuring the Outputs
28
Signals and Error Codes for the Output
28
Digital Outputs for F2 DO 16 02
29
Table 17: ELOP II Factory - Digital Output System Signals
29
5 Operation
30
Handling
30
Diagnosis
30
6 Maintenance
31
Faults
31
Operating System Version 6.42 and Beyond
31
Operating System Versions Prior to 6.42
31
Maintenance Measures
31
Loading the Operating System
31
Proof Test
31
7 Decommissioning
32
8 Transport
33
9 Disposal
34
Appendix
35
Glossary
35
Index of Figures
36
Index of Tables
37
Index
38
Advertisement
Related Products
HIMA HIMatrix F60
HIMA HIMatrix F1 DI 16 01
HIMA HIMatrix F3 DIO 20/8 02
HIMA HIMatrix F20
HIMA HIMatrix F30
HIMA HIMatrix F3
HIMA HIMatrix F35
HIMA HIMatrix F60 DI 32 01
HIMA HIMatrix F3 DIO 16/8 01
HIMA HIMatrix F30 014
HIMA Categories
Controller
Control Unit
I/O Systems
Industrial Equipment
Temperature Controller
More HIMA Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL