Sign In
Upload
Manuals
Brands
Emerson Manuals
UPS
Liebert NXL series
Emerson Liebert NXL series Manuals
Manuals and User Guides for Emerson Liebert NXL series. We have
1
Emerson Liebert NXL series manual available for free PDF download: Operation And Maintenance Manual
Emerson Liebert NXL series Operation And Maintenance Manual (96 pages)
250 to 800kVA, 50/60Hz, Three Phase Single-Module and 1+N
Brand:
Emerson
| Category:
UPS
| Size: 5.54 MB
Table of Contents
Table of Contents
5
Save These Instructions
10
1 Introduction
11
General Description
11
Modes of Operation
11
Normal Mode
11
Figure 1 Typical UPS System One-Line Diagram
11
Bypass Mode
12
Battery Mode
12
Maintenance Bypass
12
Options
13
2 Operation
14
Features
14
Figure 2 Main Component Locations
15
Figure 3 Main Display Screen, Typical
16
Figure 4 MIMIC Display
16
Figure 5 Monitor/MIMIC Display Example: Normal Power Flow
17
Figure 6 Monitor/MIMIC Display Example: Utility Fail
17
Figure 7 Monitor/MIMIC Display Example: Load on Bypass, UPS on
18
Figure 8 Monitor/MIMIC Display Example: Load on Bypass, UPS Module off
18
Touchscreen Navigation
19
Main Display Screen
19
Help
19
Metering
19
Silence
19
Reset
19
Figure 9 Menu Tree
19
Configurations Menu
20
Figure 10 Rating Parameters
20
Figure 11 System Settings Parameters
21
Figure 12 Adjustable Setpoints Parameters
22
Figure 13 Battery Equalize Settings
23
Figure 14 Battery Management Parameters
23
Figure 15 Typical Event Management Parameters
25
Figure 16 Load Bus Sync Screen
26
Figure 17 Input Contact Isolator Board Screen
26
Figure 18 Programmable Relay Board Screen
27
Status Reports Menu
28
Figure 19 Event Log
28
Startup Menu
29
Shutdown Menu
29
Figure 20 Shutdown Menu
29
Figure 21 UPS Shutdown Popup
30
Figure 22 System Shutdown Popup
30
Transfer Menu
31
Battery Management Menu
31
Figure 23 Transfer/Retransfer Commands
31
Figure 24 Time Remaining Display
32
Figure 25 Battery Cycle Monitor
33
Figure 26 Battery Cycle Monitor Summary
34
Figure 27 Battery Cycle Monitor-Clear Log
34
Modes of Operation
35
Load on Bypass
35
Figure 28 Load on Bypass (UPS Not Available)
35
OK to Transfer
36
Input Power Failure-Load on Battery
36
Figure 29 Load on Bypass, UPS Available
36
Figure 30 Load on UPS, Bypass Available
36
Off Battery
37
Figure 31 Input Power Fail, Load on Battery
37
Figure 32 Load on UPS, Battery Not Available
37
Emergency Power off (EPO)
38
Remote Emergency Power off (REPO)
38
Figure 33 Emergency Power off
38
Figure 34 Remote Emergency Power off
38
Manual Procedures
39
Startup Procedure
39
Load Transfer Procedures
42
Figure 35 Start-Up Commands
42
Maintenance Bypass Load Transfers
43
Figure 36 Maintenance Bypass Transfers
43
Shutdown Procedures
45
Module Shutdown Procedure
45
Automatic Operations
46
Overloads (Without Transfer)
46
Figure 37 Current-Versus-Time Curves of Overload Capacity
46
Automatic Transfers to Bypass (Overload Condition)
47
Automatic Transfers to Bypass, UPS System Faults
47
Automatic Retransfers to UPS
48
1+N System Operating Procedures
49
General
49
Introduction
49
Preliminary Checks
49
System Start-Up
49
Figure 38 Manual Start to Bypass
50
Figure 39 Manual Start to Bypass (One or more Modules)
50
Figure 40 Rectifier on Command
51
Figure 41 Load on Bypass, UPS Available
51
Figure 42 Load on Bypass, BCB Closed
52
Figure 43 Load on UPS
52
Figure 44 Parallel System View
53
Cut off and Separate One UPS Module from the Running Parallel System
54
Recover the UPS Module Separated from Parallel System
54
The Steps of Shutdown UPS and Load
54
Figure 45 Starting 1+N System Shutdown
55
Figure 46 1+N System Shutdown Confirm
55
The Steps of Operation of Maintenance Bypass
56
Figure 47 1+N System Shutdown
56
3 Maintenance
57
Safety Precautions
57
Liebert Services
58
Professional Start-Up
58
Routine Maintenance
59
Record Log
59
Air Filters
59
Limited Life Components
60
Battery Maintenance
61
Battery Safety Precautions
61
Batteries
63
Detecting Trouble
64
Reporting a Problem
64
Corrective Actions
64
4 Specifications
65
Battery Operation
65
Environmental Conditions
65
Table 4: Electrical Specifications (250-300-400Kva UPS)
66
Table 5: Specifications (800Kva UPS)
68
5 Appendix A-Ups Alarm and Status Messages
70
Advertisement
Advertisement
Related Products
Emerson Liebert NX
Emerson Liebert NXL
Emerson Liebert NX Series
Emerson Liebert NXr
Emerson Liebert GXT-MT
Emerson Liebert APS
Emerson Liebert GXT
Emerson Liebert Series 610
Emerson Liebert HiPulse E Series
Emerson Liebert eXM
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL