Sign In
Upload
Manuals
Brands
Emerson Manuals
UPS
Liebert GXT4-6000RT230
Emerson Liebert GXT4-6000RT230 Manuals
Manuals and User Guides for Emerson Liebert GXT4-6000RT230. We have
4
Emerson Liebert GXT4-6000RT230 manuals available for free PDF download: User Manual
Emerson Liebert GXT4-6000RT230 User Manual (68 pages)
Liebert GXT4 230 V, 5000 VA – 10,000 VA
Brand:
Emerson
| Category:
UPS
| Size: 7.24 MB
Table of Contents
Table of Contents
3
Important Safety Precautions
9
Battery Safety
10
Information for the Protection of the Environment
10
Glossary of Symbols
12
1 Product Description
13
Features
13
Available Models
13
Table 1-1: UPS Models, Power Ratings
13
Appearance and Components
14
Appearance
14
Rear Panel Features
14
Figure 1-1 Liebert GXT4 5000VA and 6000VA, Front View
14
Figure 1-2 Rear Panel-5000VA and 6000VA
15
Figure 1-3 Rear Panel-8000VA and 10,000VA
15
Removable Power Distribution Box
16
Internal Battery Packs
16
Figure 1-4 Power Distribution Box for 5000 VA and 6000 VA Models
16
Figure 1-5 Power Distribution Box for 10,000 VA Models
16
Figure 1-6 Internal Battery Pack with Connector
16
Major Components
17
Transient Voltage Surge Suppression (TVSS) and EMI/RFI Filters
17
Rectifier/Power Factor Correction (PFC) Circuit
17
Inverter
17
Battery Charger
17
DC-To-DC Converter
18
Battery
18
Internal Bypass
18
Maintenance Bypass
18
Operating Mode
18
Mains Mode
18
Manual Bypass Mode
18
Battery Mode
19
Battery Recharge Mode
19
Frequency Converter Mode
19
Active ECO Mode
20
2 Installation
21
Unpacking and Inspection
21
What's Included
21
Preparation for Installation
22
Installation Environment
22
Install the Main Cabinet
22
Tower UPS Installation
22
Figure 2-1 Support Bases
22
Rack Installation
23
Figure 2-2 Remove the Front Plastic Bezel Cover
23
Figure 2-3 Rotate the Operation and Display Panel
23
External Battery Cabinet Installation
24
Figure 2-4 External Battery Cabinets Connected to GXT4
24
Connect Input/Output Power
25
Install the Power Distribution Box
25
Remove the Power Distribution Box
25
Distribution Box Electrical Connections
26
Figure 2-5 Power Distribution Box Removal
26
Table 2-1: Branch Circuit Breaker Ratings
26
Terminal Block Connections
27
Figure 2-6 Distribution Box Electrical Connections Diagram
27
Figure 2-7: Terminal Block Connections
27
Table 2-2: Electrical Specifications
27
IT Power System Configuration
28
Figure 3 Remove Cover from IT Power System Connectors Compartment
28
3 Operation and Display Panel
29
LED Indicators
29
Figure 3-1 Operation and Display Panel
29
Table 3-1: LED Indicators
29
Control Buttons
30
Lcd
30
Table 3-2 Control Buttons
30
Menu Structure
31
Figure 3-2 Menu Structure
31
Figure 3-3 Startup Screen
32
Figure 3-4: Startup Screens
32
Figure 3-5: Starting and Start Successful Screens
32
Startup Screen
32
Default Screen
33
Figure 3-6 Default Screen
33
Figure 3-7 Main Menu Screen
33
Main Menu Screen
33
Figure 3-8: Status Screens
34
Figure 3-9 CONFIGURATION Screen
34
Figure 3-10: UPS Screens
35
Figure 3-11 Battery Screen
35
Figure 3-12 ECO Mode Screen
36
Figure 3-13 LCD Screen
36
Figure 3-14 Language Screen
37
Figure 3-15 Color Screen
37
Figure 3-16 Factory Default Screen
37
Figure 3-17 Control Screen
38
Figure 3-18 Turn UPS on or off Screen
38
Figure 3-19 Alarm Control Screen
39
Figure 3-20 Batt Test Screen
39
Figure 3-21: Log Screens
39
Figure 3-22 Clear Log Screen
40
Figure 3-23 about Screen
40
Figure 3-24: Network Screens
41
Prompt List
42
Table 3-3: System Prompts and Meanings
42
Table 3-4: Warning List
42
Warning List
42
Fault List
43
Table 3-5 Fault List
43
4 Operation
45
Startup Checklist for the Liebert GXT4
45
Starting the UPS
45
Manual Battery Test
45
Manual Bypass
46
Shut down the GXT4
46
Disconnecting Input Power from the GXT4
46
Maintenance Bypass
46
5 Communication
47
Liebert Intellislot Communication Cards
47
Liebert Multilink
47
USB Port Communication
48
Configuration Program
48
Table 5-1 Output Voltage Option
48
Terminal Block Communication
49
Any Mode Shutdown
49
Figure 5-1 Terminal-Block Communication Pin Layout
49
Battery Mode Shutdown
50
On Battery
50
Low Battery
50
Remote Emergency Power Off-GXT4-6000RTL630
51
Figure 5-2 REPO Switch Connection Diagram
51
6 Maintenance
53
Replacing the Internal Battery Pack
53
Table 6-1: Replacement Internal Battery Pack Model Number
53
Battery Replacement Procedures
54
Figure 6-1 Removing the Front Bezel Cover and Battery Door
54
Battery Charging
55
Precautions
56
Checking UPS Status
56
Checking UPS Functions
56
7 Troubleshooting
57
UPS Symptoms
57
Indicator and LCD
57
Table 7-1: Description of the Displayed Fault
57
Audible Alarm
58
Troubleshooting
58
Table 7-2: Audible Alarm Description
58
Table 7-3 Troubleshooting Table
58
8 Specifications
61
Table 8-1: UPS Specifications
62
Table 8-2 Power Distribution Specifications
62
Table 8-3: External Battery Cabinet Specifications
63
Table 8-4 Battery Run Time, Minutes, All Models
64
Auto-Learning Battery Run Times
66
Product Warranty Registration
66
Technical Support
66
Advertisement
Emerson Liebert GXT4-6000RT230 User Manual (56 pages)
230V, 5000-10,000VA UPS
Brand:
Emerson
| Category:
UPS
| Size: 3.55 MB
Table of Contents
Table of Contents
3
Important Safety Precautions
7
Save These Instructions
7
Glossary O F Symbols
9
1 Product Description
10
Features
10
Available Models
10
Table 1 UPS Models, Power Ratings
10
Appearance and Components
11
Appearance
11
Figure 1 Liebert GXT4 5000VA and 6000VA, Front View
11
Rear Panel Features
12
Figure 2 Liebert GXT4, Rear View-5000 and 6000VA
12
Figure 3 Liebert GXT4, Rear View-10,000VA
12
Internal Battery Packs
13
Removable Power Distribution Box
13
Figure 4 Internal Battery Pack with Connector
13
Figure 5 Power Distribution Box for GXT4 5000VA and 6000VA Models
13
Figure 6 Power Distribution Box for GXT4 10,000VA Model
13
Major Components
14
Transient Voltage Surge Suppression (TVSS) and EMI/RFI Filters
14
Rectifier/Power Factor Correction (PFC) Circuit
14
Inverter
14
Battery Charger
14
DC-To-DC Converter
14
Battery
15
Internal Bypass
15
Maintenance Bypass
15
Operating Mode
15
Mains Mode
15
Manual Bypass Mode
15
Battery Mode
16
Battery Recharge Mode
16
Frequency Converter Mode
16
Active ECO Mode
16
2 Installation
17
Unpacking and Inspection
17
What's Included
17
Preparation for Installation
17
Installation Environment
17
Install the Main Cabinet
18
Tower UPS Installation
18
Figure 7 Support Bases
18
Figure 8 Remove the Front Plastic Bezel Cover
18
Figure 9 Rotate the Operation and Display Panel
18
Rack Installation
19
External Battery Cabinet Installation
19
Figure 10 External Battery Cabinets Connected to 10,000VA Liebert GXT4
19
Connect Input/Output Power
20
Figure 11 Power Distribution Box Removal-Captive Screws and Maintenance Bypass Breaker
20
Distribution Box Electrical Connections
21
Figure 12 Distribution Box Electrical Connections Diagram
21
Figure 13 Terminal Block Connections-PD2-CE6HDWRMBS and PD2-CE10HDWRMBS
21
IT Power System Configuration
22
Figure 14 Remove Cover from IT Power System Connectors Compartment
22
3 Operation and Display Panel
23
LED Indicators
23
Figure 15 Operation and Display Panel
23
Table 4 LED Indicators
23
Control Buttons
24
Lcd
24
Menu Structure
24
Table 5 Control Buttons
24
Figure 16 Menu Structure
25
Figure 17 Startup Screen
26
Figure 18 Startup Screens
26
Figure 19 Starting and Start Successful Screens
26
Startup Screen
26
Default Screen
27
Figure 20 Default Screen
27
Figure 21 Main Menu Screen
27
Main Menu Screen
27
Figure 22 Status Screens
28
Figure 23 CONFIGURATION Screen
28
Figure 24 UPS Screens
29
Figure 25 Parallel Screen-10Kva Units Only
29
Figure 26 Battery Screen
30
Figure 27 ECO Mode Screen
30
Figure 28 LCD Screen
31
Figure 29 Language Screen
31
Figure 30 Color Screen
31
Figure 31 Factory Default Screen
32
Figure 32 Control Screen
32
Figure 33 Turn UPS on or off Screen
32
Figure 34 Alarm Control Screen
33
Figure 35 Batt Test Screen
33
Figure 36 Log Screens
33
Figure 37 Clear Log Screen
34
Figure 38 about Screen
34
Figure 39 Network Screens
35
Prompt List
35
Table 6 Prompts and Meanings
35
Fault List
36
Table 7 Warning List
36
Table 8 Fault List
36
Warning List
36
4 Operation
37
Startup Checklist for the Liebert GXT4
37
Starting the UPS
37
Manual Battery Test
37
Manual Bypass
37
Shut down the Liebert GXT4
37
Disconnecting Input Power from the Liebert GXT4
38
Maintenance Bypass
38
5 Communication
39
Liebert Intellislot ® Communication Cards
39
Liebert Multilink
39
USB Port Communication
39
Configuration Program
40
Table 9 Output Voltage Option, All Models
40
Terminal Block Communication
41
Any Mode Shutdown
41
Figure 40 Terminal Block Communication Pin Layout
41
Battery Mode Shutdown
42
On Battery
42
Low Battery
42
Remote Emergency Power off
43
Figure 41 REPO Switch Connection Diagram
43
6 Maintenance
44
Replacing the Internal Battery Pack
44
Battery Replacement Procedures
44
Figure 42 Removing the Front Plastic Bezel Cover and Battery Door
44
Figure 43 Disconnecting the Battery Plug and Battery Receptacle, Front View
44
Battery Charging
45
Precautions
45
Figure 44 Pulling out the Battery Packs
45
Checking UPS Status
46
Checking UPS Functions
46
7 Troubleshooting
47
UPS Symptoms
47
Indicator and LCD
47
Audible Alarm
48
Troubleshooting-Problems, Causes, Solutions
48
8 Specifications
49
Table 11 Table
49
Table 13 UPS Specifications
50
Table 14 Power Distribution Specifications
50
Table 15 External Battery Cabinet Specifications
51
Table 16 Battery Run Time, Minutes, All Models
52
Auto-Learning Battery Run Times
54
Product Warranty Registration
54
Technical Support
54
Emerson Liebert GXT4-6000RT230 User Manual (50 pages)
Liebert GXT4 5000VA ~ 10000VA (230V)
Brand:
Emerson
| Category:
UPS
| Size: 2.08 MB
Table of Contents
Important Safety Precautions
3
Save These Instructions
3
Information for the Protection of the Environment
4
Table of Contents
7
Chapter 1 Introduction
9
Chapter 2 System Description
10
Transient Voltage Surge Suppression (TVSS) and EMI/RFI Filters
10
Rectifier/Power Factor Correction (PFC) Circuit
10
Inverter
10
Battery Charger
10
DC-To-DC Converter
10
Battery
11
Dynamic Bypass
11
Chapter 3 Major Components
12
Main Frame and Electronics
12
Removable Power Distribution Box
13
Internal Battery Packs
14
Chapter 4 What's Included
15
Chapter 5 Installation and Configuration
16
Install Main Cabinet
16
Tower UPS Installation
16
Rack-Mount UPS Installation
17
Installing Adjustable Rack-Mount Kit-Sold Separately
17
External Battery Cabinet Installation
20
Connect Input/Output Power
22
Chapter 6 Configuration Program
25
Configuration Program Features
25
What You will Need
25
Chapter 7 Operation and Display Panel
26
LED Indicators
26
Control Buttons
26
LCD Display Panel
27
Startup Screen
27
ON Screen
27
Default Screen
27
Main Menu Screen
28
Prompt List
32
Warning List
33
Fault List
34
Chapter 8 Operation
35
Startup Checklist for Liebert GXT4
35
Initial Startup and Electrical Checks
35
Manual Battery Test
35
Put Liebert® GXT4™ in Bypass
35
Shut down Liebert GXT4
36
Disconnecting Input Power from Liebert GXT4
36
Maintenance Bypass
36
IT Power System Configuration
36
Chapter 9 Communication
38
Communication Interface Port
38
Terminal Block
38
Any-Mode Shutdown
38
Battery Mode Shutdown
38
On Battery
39
Low Battery
39
Liebert Intellislot® Communication Cards
39
Liebert® Multilink
39
Remote Emergency Power off
40
Chapter 10 Maintenance
41
Replacing Internal Battery Pack
41
Battery Charging
43
Precautions
43
Checking UPS Status
43
Checking UPS Functions
43
Chapter 11 Specifications
44
Chapter 12 Product Warranty Registration
48
Advertisement
Emerson Liebert GXT4-6000RT230 User Manual (13 pages)
Liebert GXT4 5000VA ~ 10000VA (230V)
Brand:
Emerson
| Category:
UPS
| Size: 0.14 MB
Table of Contents
System Description
2
Modes of Operation
2
Design Requirements
3
Performance Requirements
4
Environmental Conditions
6
User Documentation
6
Quality Assurance
6
Factory Testing
6
Display and Controls
9
Automatic Transfers
10
Internal Battery
10
On-Board Communication
11
Communication Options
11
Liebert Intellislot ® Communication Cards
11
Configuration Program
12
Advertisement
Related Products
Emerson Liebert GXT4-6000RT230E
Emerson Liebert GXT4-6000RT208
Emerson Liebert GXT4-6000RTL630
Emerson Liebert GXT4
Emerson Liebert GXT4-10000RT230
Emerson Liebert GXT4-1000RT230
Emerson Liebert GXT4-3000RT230
Emerson Liebert GXT4-2000RT230E
Emerson Liebert GXT4-1500RT230E
Emerson Liebert GXT4-10000RT208
Emerson Categories
Controller
Control Unit
Transmitter
Measuring Instruments
Fan
More Emerson Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL