Sign In
Upload
Manuals
Brands
Desert Aire Manuals
Controller
CM3510 Series
Desert Aire CM3510 Series Controller Manuals
Manuals and User Guides for Desert Aire CM3510 Series Controller. We have
3
Desert Aire CM3510 Series Controller manuals available for free PDF download: Installation And Operation Manual
Desert Aire CM3510 Series Installation And Operation Manual (80 pages)
For SA Units, Remote Display Terminal
Brand:
Desert Aire
| Category:
Controller
| Size: 8 MB
Table of Contents
Table of Contents
7
Overview
9
1 Field Installation of CM3510 Control Sensors
9
Duct-Mounted Sensor
9
Wall Mount Humidity and Temperature Sensor
9
Water Temperature Sensor (Pool Water Heating Option Only)
9
Auxiliary Air Heating Control Wiring
10
Auxiliary Heating - Dry Contact Closure
10
Auxiliary Heating - Proportional Signal
10
CM3510 Controller Overview
10
2 SA Controller Details
13
Menu Overview and General Instructions
13
Main Menu
14
Status Menu
14
Unit Status
15
I/O Status
17
Digital Inputs (Binary)
18
Analog Inputs
22
Digital Outputs (Binary)
25
Analog Outputs
28
EXV Status
30
Pressure Cutouts
30
Setpoint Menu
31
Occupancy Schedule
32
Schedule Options
33
Temporary Holidays
34
Annual Holidays
35
Temporary Occupancy
36
Temporary Overrides
36
Set Time
37
Service Menu
38
Tmp/Rh Settings
38
Deadbands
39
Air Differentials
41
Energy Recovery
42
Pool 1 or 2 Settings
43
Aux Heat Settings
44
Cond/Roof Settings
47
Sensor Offsets
49
Airflow Menu
50
Airflow Setup
51
Airflow PID Loops
56
Low Exhaust Settings
60
Max O/A Settings
60
Economizer Settings
61
Unit Revision
63
Alarms
63
Alarm Screen
63
Low Suction Pressure Circuit a or Circuit B
64
High Discharge Pressure Circuit a or Circuit B
64
Supply Air Temperature Sensor Failure
65
Zone Air Temperature Sensor Failure
65
Supply Blower or Exhaust Blower Motor Overload
65
Compressor a or B Motor Overload
65
System Shutdown
65
Low Supply Air Temperature
66
Low Voltage (Optional Low Voltage Monitor Needed to Activate Alarm)
66
Low Air Flow
66
Freeze Stat Alarm (Units Equipped with Hot Water Coil Option Only)
66
Evacuator VFD Overload
66
Alarm History Screen
66
3 Hardware Details
69
Programmable Controller
69
Suction Pressure Transducer
69
Discharge Pressure Transducer
69
Differential Air Pressure Transducer
70
Temperature Sensor
70
Zone Air Temperature and Relative Humidity Sensor
70
4 Appendix
71
Remote Communication
71
Bacnet Ethernet
71
Bacnet MS/TP
75
Advertisement
Desert Aire CM3510 Series Installation And Operation Manual (64 pages)
Brand:
Desert Aire
| Category:
Controller
| Size: 13 MB
Table of Contents
Table of Contents
7
1 Installation
9
Introduction
9
Sensor Installation
9
Unit Sensor Installation
10
Wall Mount Humidity and Temperature Sensor
10
Water Temperature Sensors
10
Outdoor Air Mounted Humidity and Temperature Sensor
10
Auxiliary Air Heating Control Wiring
10
Auxiliary Heating - Dry Contact Closure
10
Auxiliary Heating - Proportional Signal
11
CM3560 Controller Overview
11
2 CM3560 Controller Details
12
Menu Overview and General Instructions (Figure 1)
12
Zone Setpoints (Figure 2)
14
Main Menu (Figure 4)
15
Status Menu (Figure 5)
15
Occupacy Schedule (Figure 10)
17
Time/Date (Figure 11)
18
Daily Events (Figure 12)
18
Vacation Periods (Figure 13)
19
Special Days (Figure 14)
19
Temporary Occupancy (Figure 15)
20
Service Menu (Figures 16 and 17)
20
Commissioning (Figure 18)
21
Configuration (Figure 19)
21
Supply Blower Setup (Figure 31)
26
Exhaust Blower Setup (Figure 35)
28
Airflow Setup (Figure 41)
31
BMS Setup (Figures 55 through 62)
36
Tuning - Dead Bands (Figure 63)
39
Tuning - Differentials (Figure 64)
40
Tuning - Energy Recovery (Figure 65)
41
Tuning - Pool Settings (Figures 66 & 67)
41
Tuning - Air Heating (Figures 68 through 71)
42
Tuning - Outdoor Air Pre-Heating (Figure 72 & 73)
44
Tuning - Maximum Outdoor Air (Figure 74)
44
I/O Status (Figure 75)
45
Digital Inputs (Binary) (Figure 76 through 80)
45
Analog Inputs (Figures 81 through 90)
49
Digital Outputs (Binary) (Figures 87 through 93)
52
Analog Outputs (Figures 94 through 97)
54
Sensor Offsets (Figures 97 - 103)
55
Memory Options (Figures 104 - 106)
57
Unit Revision (Figure 107)
58
3 Alarm Menu
59
System Alarms
60
EEV Alarms
60
Alarm Log (Figure 111)
60
4 Hardware Details
61
Programmable Controller
61
Suction Pressure Transducers
61
Discharge & Liquid Pressure Transducers
62
Suction, Liquid, Pool & Supply Air Temperature Sensors
62
Zone and Outdoor Air Temperature and Relative Humidity Sensors
62
Differential Air Pressure Sensors
62
5 Appendix
63
Internal Web Page
63
Desert Aire CM3510 Series Installation And Operation Manual (60 pages)
Brand:
Desert Aire
| Category:
Controller
| Size: 10 MB
Table of Contents
Table of Contents
7
1 Installation
9
Introduction
9
Sensor Installation
9
Unit Mounted Sensor
9
Wall Mount Humidity and Temperature Sensor
10
Water Temperature Sensors
10
Outdoor Air Mounted Humidity and Temperature Sensor
10
Auxiliary Air Heating Control Wiring
10
Auxiliary Heating - Dry Contact Closure
10
Auxiliary Heating - Proportional Signal
11
CM3510 Controller Overview
11
2 Controller Details
12
Menu Overview and General Instructions (Figure 1)
12
Zone Setpoints (Figure 2)
13
Main Menu (Figure 4)
14
Unit Status (Figure 5)
15
Occupancy Schedule (Figure 10)
17
Time/Date (Figure 11)
18
Daily Events (Figure 12)
18
Vacation Periods (Figure 13)
19
Special Days (Figure 14)
19
Temporary Occupancy (Figure 15)
19
Service Menu (Figures 16 and 17)
20
Commissioning (Figure 18)
21
Configuration (Figure 19)
21
Exhaust Blower Setup (Figure 31)
26
Airflow Setup (Figure 36)
29
BMS Setup (Figures 45 through 52)
33
Tuning - Dead Bands (Figure 53)
36
Tuning - Energy Recovery (Figure 55)
38
Tuning - Pool Settings (Figures 56 & 57)
38
Tuning - Air Heating (Figures 58 - 61)
39
Tuning - Outdoor Air Pre-Heating (Figures 62 & 63)
40
Tuning - Maximum Outdoor Air (Figure 64)
41
I/O Status (Figure 65)
42
Digital Inputs (Binary) (Figures 66 - 80)
42
Analog Inputs (Figures 69 Thru 77)
45
Digital Outputs (Binary) (Figures 78 - 81)
48
Analog Outputs (Figures 82 - 83)
50
Sensor Offsets (Figures 84 - 91)
51
Memory Options (Figures 92 - 94)
54
Unit Revision (Figures 95)
55
3 Alarm Menu
56
System Alarms
57
EEV Alarms
57
Alarm Log (Figure 99)
57
4 Hardware Details
58
Programmable Controller
58
Suction Pressure Transducers
58
Discharge & Liquid Pressure Transducers
58
Suction, Liquid, Pool & Supply Air Temperature Sensors
59
Zone and Outdoor Air Temperature and Relative Humidity Sensors
59
Differential Air Pressure Sensors
59
5 Appendix
59
Internal Web Page
59
Advertisement
Advertisement
Related Products
Desert Aire CM3540 Series
Desert Aire CM3530 Series
Desert Aire CM3500 Series
Desert Aire CM3550 Series
Desert Aire CM35xx
Desert Aire CM3560 Series
Desert Aire CM3570 Series
Desert Aire CM3554 Series
Desert Aire Categories
Controller
Dehumidifier
Air Cleaner
Fan
Air Conditioner
More Desert Aire Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL