Data Aire GUGU 045 Manuals
Manuals and User Guides for Data Aire GUGU 045. We have
1
Data Aire GUGU 045 manual available for free PDF download: User Manual
Data Aire GUGU 045 User Manual (133 pages)
DX, Single and Dual Circuit 36, 45, 56, 70 and 106 kW
Brand:
Data Aire
| Category:
Air Conditioner
| Size: 2.1 MB
Table of Contents
Table of Contents
3
1 Introduction
7
Product Information
7
Model Identification
8
Inspection
8
Paperwork
9
2 Installation
10
Installation Checklist
10
Room Considerations
10
Equipment Handling
11
Rigging
11
Locating the Unit
12
Downflow Units
12
Upflow Units
13
Storage
14
Piping
14
Air Cooled Unit Piping
15
Discharge Lines
16
Liquid Lines
17
Connection Sizes, Air Cooled Units
17
Field Piping, Remote Condenser
18
Water/Glycol Cooled Unit Piping
18
Field Piping, Water/Glycol System
20
Connection Sizes, Water/Glycol Cooled Units
21
Connection Sizes, Fluid Coolers
21
Auxiliary Chilled Water/Energy Saver Coil Piping
21
Condensate Drain Piping
21
Humidifier Piping
23
Steam Generator Humidifier
23
Leak Testing
23
Evacuation
24
3 Electrical Connections
26
Electrical Service
26
Nameplate Ratings
26
Grounding
27
Voltage Tolerance
27
Auxiliary Control Wiring
27
Remote Shutdown
27
Remote Alarm Contacts
28
Condensate Pumps
28
Condensate Probe
29
Water Sensing Cable (Optional)
29
Remote Temperature and Humidity Sensors (Optional)
30
Manual Override Switches
30
Wiring Diagrams
31
4 Installation of Remote Outdoor Heat Exchanger
32
5 Charging
32
General Charging Guidelines
32
Voltage Phase Check
32
Evaporator
32
Secondary Heat Exchanger
33
Fan Speed Control System
34
Air Cooled Systems
34
Charging
34
Flooded System Charging
37
Water/Glycol System
41
Water/Glycol Cooled System Charging
41
Check a Running Compressor
42
Refrigerant Handling
42
Commissioning
43
Important Refrigeration Components
43
Variable Capacity Compressor with VFD
43
Electronic Expansion Valve
44
High Pressure Cutout Switch
44
Low Pressure Cutout Switch
44
Liquid Line Solenoid Valve
44
6 Glycol Systems
46
Glycol Concentration
46
Internal (Fluid) Volume - Downflow Units
46
Internal (Fluid) Volume - Upflow Units
46
Internal (Fluid) Volume - Fluid Coolers
47
Fluid Cooler Information
47
7 Variable Speed Compressor
48
Features
48
Oil Management
48
Crankcase Heaters
48
Oil Level
49
VFD Drive
50
Local Control for Charging
51
View Drive Alarms
52
8 Controls
53
Dap4™ Microprocessor Control Panel
53
Control Module
53
Display Module
54
Buttons
54
Accessing Menus/Passwords
54
Changing the Service Level Password
56
Entering Menu Settings
56
Menu a - ON/OFF
57
Menu B - Setpoints
58
Menu C - Clock/Scheduler
62
Menu D - Input/Output
62
Menu E - Historical Data
62
Menu F - Information
65
Menu G - Network Config
65
Menu H - Calibrate Sensors
68
Menu I - Manual Control
71
Menu J - Factory Settings
75
Menu K - Alarms & Limits
88
Menu L - Configure I/O
99
Zone Master
99
Secondary Heat Exchangers
99
9 Control Logic
100
Fan Control Logic
100
Fan Speed Modulation to Rack Temperature (Mod to Rack)
100
Fan Speed Modulation Proportional to Cooling Demand (Mod to Comp)
101
Fan Speed Modulation to Return Air (RA) Temperature (Mod to Rett)
101
Fan Speed Modulation to Constant Static Pressure (Air Pressure)
101
Fan Speed Modulation Based on BMS (BMS Speed)
101
Constant Fan Speed (Const Speed)
102
Compressor
102
Return Air Temperature Control Mode
102
Discharge Air Temperature Control Mode
107
Safeties and Alarms
110
Dehumidification Mode
112
Relative Humidity Control Mode
113
Dewpoint Control Mode
115
10 Regular Maintenance Items
118
Air Filters
118
Fuses
118
Electric Reheat
119
Humidifier
119
Humidifier Canisters
119
Refrigerant Filter Drier
119
Current Sensing Relay
120
Plug Fans
122
Electronically Commutated Motors
122
Testing
124
11 Recommended Line Sizing
125
Hot Gas Lines - Single Circuit Units (up to 200 Equivalent Feet (61 M))
125
Hot Gas Lines - Dual Circuit Units (up to 200 Equivalent Feet (61 M))
125
Liquid Lines - Single Circuit Units (up to 200 Equivalent Feet (61 M))
125
Liquid Lines - Dual Circuit Units (up to 200 Equivalent Feet (61 M))
125
12 Contact Data Aire
126
13 Maintenance/Inspection Checklist
127
Advertisement
Advertisement
Related Products
Data Aire GUGD 036
Data Aire GUGD 045
Data Aire GUGD 056
Data Aire GUGD 070
Data Aire GUGD 106
Data Aire GUGU 036
Data Aire GUGU 056
Data Aire GUGU 070
Data Aire GUGU 106
Data Aire gForce Ultra
Data Aire Categories
Air Conditioner
Control Systems
Accessories
Control Unit
Network Card
More Data Aire Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL