5. Refrigerating Cycle Block Diagram
INDOOR UNIT
T1
(A)
(B)
Heat
exchanger
(Evaporator)
T2
Refrigerating cycle temperature and pressure
Operating Condition
Standard
Cooling
Max over load
Low temp.
Standard
Heating
Max over load
Deice
2Way valve
Liquid side
Capillary tube
Gas side
Compressor-A
3Way valve
STD Pressure
Piping Temp.(°F)
(psi)
T1
3-WAY V/V
57-71
50-54
-
61-64
-
34-39
242-284
90-97
-
97-104
-
82-90
OUTDOOR UNIT
Check valve
Capillary tube
Heat
exchanger
(Condenser)
Compressor-B
4Way valve
Temp. Condition (°F)
Indoor
T2
DB
WB
50-54
80
61-64
80
34-39
67
140-158
70
149-167
80
104-113
70
Outdoor
DB
WB
67
95
75
67
115
75
57
67
57
60
47
43
-
75
65
60
35
33
31