Samsung AD26B1C13 Service Manual page 10

Table of Contents

Advertisement

If the lamp is not flickering, check as follows:
A. Check the display part of indoor unit of each unit (A,B) after outdoor unit PCB switch S/W-A is on.
A.
Check the status of each unit indoor room select switch.
A.
(Adjust the select switch suitable to the unit A, B.)
A.
- A unit : STANDARD LED on, TIMER LED flickering
A.
- B unit : STANDARD LED on, TIMER and NATURE LED flickering
A.
- C unit : STANDARD LED on, TIMER and NATURE, POWER LED flickering (In case of triple
split multi air conditioner)
4. Check the test operation status by pressing the PCB switch
4.
S/W-A and S/W-B of outdoor unit.
4.
• Check the operation status by pushing the switch one at time.
4.
• Perform the test operation only for the unit selected last.
4.
• Check the pipe pressure and the other operation status during the test operation.
4.
• Check items when the error occurs during the test operation (each unit)
- Check there is enough refrigerant.
- Check pipe connections.
STANDARD
TIMER
UNIT
A
B
C
Lamp ON
Lamp OFF
NATURE
POWER
Lamp Flasher
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ad18b1c09Ud26b1c2Ud18b1c2

Table of Contents