Professional
Slide-In Range Specifications
Product Shipping Weight (approx.) – 250 Lbs.
•
•
Single phase 3- or 4-wire cable, 120 / 240 or 120 / 208 Volt,
60 Hertz, fused on both sides of line with ground. (If local code
permits, range may be connected by hard-wiring or by means
of power supply cord kit.)
•
Connected Load (kW Rating) @ 240 / 208 Volts = 4.3 / 3.2 kW
•
Amps @ 240 / 208 Volts = 17.9 / 15.4 Amps
•
Always consult local and national electric and gas codes.
•
Make sure wall coverings around range can withstand heat generated
by range.
Linoleum or any other synthetic floor covering located beneath range,
•
must be capable of withstanding minimum heat of 90° F above room
temperature without shrinking, warping or discoloring. Insulating pad
or 1/4"-thick plywood required between range and a carpeted floor.
•
Do not obstruct flow of combustion air at oven vent nor around base
or beneath lower front panel of range. Range requires fresh air for
proper burner combustion.
•
Range ships with 3/4" factory regulator.
•
LP Gas Conversion Kit supplied.
•
Gas supply piping can be through back wall or floor. Optimum
location is between 1" and 8" from floor through back wall within
3" of center line; can also be through floor against back wall within
12" of center line. Supply line must be equipped with approved
manual shutoff valve, accessibly located in same room as range.
•
Countertop MUST be level in all directions and adjustable range
height at least 1/16" greater than tallest cabinet height, to ensure
metal rangetop flange will fit properly on countertop edge.
•
When installing optional Backguard Kit, cutout depth of 21-3/4"
minimum / 22-1/8" maximum needs increased to 24".
•
Overhead cabinetry should not exceed a 13" maximum depth.
•
Absolute minimum horizontal distance between overhead cabinets
installed to either side of appliance must be no less than maximum
width of appliance.
USA
10200 David Taylor Drive
Charlotte, NC 28262
•
•
CANADA
5855 Terry Fox Way
Mississauga, ON L5V 3E4
•
•
FPDS3085P 12/14
1-800-FRIGIDAIRE
frigidaire.com
•
•
1-800-265-8352
frigidaire.ca
•
•
© 2014 Electrolux Home Products, Inc.
Allow 24" minimum clearance between rangetop and bottom of cabinet
•
when bottom of wood or metal cabinet is protected by not less than
1/4" flame-retardant millboard covered with not less than No. 28 MSG
sheet steel, 0.015" stainless steel, 0.024" aluminum or 0.020" copper.
Allow 30" minimum clearance when cabinet is unprotected.
•
Allow 5" minimum clearance from edge of rangetop to nearest
combustible wall on either side of unit.
•
To reduce risk of fire when using overhead cabinetry, install
range hood that projects horizontally a recommended minimum
of 5" beyond bottom of cabinets.
Countertop Preparation
Rangetop's side flanges overlap countertop cutout edges – for detailed
preparation instructions, refer to product installation guide on the web.
•
Flat Square-Finish Countertops – require no preparation since
rangetop's flange lays directly on countertop edge.
Formed Front-Edged Countertops – require front molded edge to
•
be shaved flat 3/4" from each front corner of opening.
•
Tile Countertops – may need trim cut back 3/4" from each front
corner of opening and /or rounded edge flattened.
•
For existing cutout width greater than 30-1/16" reduce the 3/4"
overlap dimension; for cutout width of 29", replace actual side
trim panels with smaller side trim panels, available with optional
Side Trim Kit (refer to detailed kit installation instructions).
Note: For planning purposes only. Refer to Product Installation Guide
on the web at frigidaire.com for detailed instructions.
Optional Accessories
•
Rear Filler Kit: Black – (PN # 901193-9010).
•
Side Panel Kit: Black – (PN # AO1529901).
•
Backguard Kit: Black – (PN # 903046-9010).
Accessories information available
on the web at frigidaire.com
Slide-In Range
FPDS3085PF
30" Dual-Fuel
Specifications
subject to change.