1. µcom/DSP/OSD Version display mode
1.1. Operation specifications
µcom/DSP/OSD version display mode:
When the set is started up in this mode, the version information is displayed.
Starting up:
Press the X button to turn on the power while pressing the "DIMMER" and "STATUS" buttons.
Now, press the "STATUS" button to the display the 2nd item information on the FL Display.
1.2. Display Order
q Model destination information → w Main-µcom version → e DSP version → r OSD version
Display
q Model destination information
AVR-E200 E3, E3B model
AVR-X500 E2, E1 model
AVR-X500 E1C model
w Main-µcom version
e DSP version
r OSD version
Cleared of mode:
Press the X button to turn the power off.
1.3. Error display
See the following table for each "Error information" display and its contents (status).
Condition
DSP NG
When DSP boot, executing DSP reset makes to becomes error.
DSP OK
State
A V R - E 2 0 0
E 3
A V R - X 5 0 0
E 2
A V R - X 5 0 0
E 1 C
M a i n
: * * . * *
D S P . * . * . *
O S D
: * * . * *
-
17
State
D S P
E R R O R
(No error display, version display only)