CAUTION:  
Before   performing   any   work   on   the   blower,   always  
switch   off   the   moter   and   pull   the   spark   plug   connec-
tors  off  the  spark  plug.
Always  wear  protective  gloves!
CAUTION:  
Start   the   blower   only   after   having   assembled   it  
completely.
1.  Assembly  of  blower  pipes
1)   Align  grooves  in  the  blower  pipe  with  pegs  on  the  blower  housing  and  
slide the pipe onto housing.
2) Tum the blower pipe clockwise to lock it into place.
2.  Assembly  of  vacuum  attachment  (Optional)
1)   Installing  Grip
(1) Remove the four screws (1).
(2)   Install  the  screws  (2),  grip  (3),  spacers  (4)  and  caps  (5)  provided  
on  the  blower  as  shown  in  the  figure.
(3) Tighten the screws (2) securely.
2)  Installing  Vacuum  Pipe  (nozzle)
(1) First, remove the screw (6).
(2)   Align  the  
(10) indicated on the vacuum pipe (9) with the
indicated on the blower. Then insert the vacuum pipe (9) into the
blower.
(3) Tum the vacuum pipe (9) until the
indicated on the blower to lock the vacuum pipe.
CAUTION:  
Hold   the   bottom   of   the   vacuum   pipe   when   turning   the  
vacuum  pipe  to  install  or  remove  it.
(10) is aligned with the