Astria Gamma26ZTN Installation And Operation Instructions Manual

Vent-free compact dual-flame fireplace

Advertisement

Quick Links

P/N 126882-01 Rev.A 02/2014
P126882-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future reference.
This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not
prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. This
appliance is not convertible for use with other gases.
This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions
for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation
section on page 6 of this manual.
WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result
causing property damage, personal injury or loss of life.
— Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other
appliance.
— WHAT TO DO IF YOU SMELL GAS:
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use any phone in your building.
• Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions.
• If you cannot reach your gas supplier, call the fire department.
— Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Installation and Operation Instructions
Astria
TM
PFS
Models
®
US
Vent-Free Compact Dual-Flame Fireplace
Gamma26ZTN
Gamma26ZTP
Gamma26ZMN
Gamma26ZMP

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gamma26ZTN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Gamma26ZTN

  • Page 1 Installation and Operation Instructions Astria Vent-Free Compact Dual-Flame Fireplace P/N 126882-01 Rev.A 02/2014 Models Gamma26ZTN Gamma26ZMN ® Gamma26ZTP Gamma26ZMP P126882-01 INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. This appliance may be installed in an aftermarket permanently located, manufactured (mobile) home, where not prohibited by local codes.
  • Page 2: Table Of Contents

    6 erate or service this fireplace. of this manual. Improper use of this fireplace can cause serious injury or death from burns, fire, explo- sion, electrical shock and carbon monoxide poisoning. www.Astria.US.com 126882-01A...
  • Page 3 • if you cannot reach your gas supplier, and draperies. call the fire department 4. This fireplace shall not be installed in a bedroom or bathroom. www.Astria.US.com 126882-01F...
  • Page 4: Product Identification

    PRODUCT IDENTIFICATION Left Side Fireplace Fireplace Cabinet Cabinet Hood Hood Screen Logs Right Ignitor Side Button Front Remote Control (Optional) Ignitor Button Control Knob Control Knob Figure 1 - Vent-Free Compact Dual Flame Fireplace www.Astria.US.com 126882-01A...
  • Page 5: Local Codes

    4. Check fireplace for any shipping damage. If fireplace is damaged, call INNOVATIVE 2. Remove all protective packaging applied HEARTH PRODUCTS at 1-800-655-2008 to fireplace for shipment. for replacement parts before returning to dealer. www.Astria.US.com 126882-01F...
  • Page 6: Hood Assembly

    Today’s homes are built more energy efficient The following are excerpts from National Fuel than ever. New materials, increased insulation Gas Code, ANSI Z223.1/NFPA 54, Air for and new construction methods help reduce Combustion and Ventilation. heat loss in homes. Home owners weather www.Astria.US.com 126882-01A...
  • Page 7 Example: 35,840 Btu/Hr (maximum the considered a part of the unconfined space. space can support) * Adjoining rooms are communicating only if 40,000 Btu/Hr (actual amount of there are doorless passageways or ventilation Btu/Hr used) grills between them. www.Astria.US.com 126882-01F...
  • Page 8 Follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, Air for Combustion and Figure 5 - Ventilation Air from Outdoors Ventilation for required size of ventilation grills or ducts. WARNING: A qualified ser- vice person must install fire- place. Follow all local codes. www.Astria.US.com 126882-01A...
  • Page 9: Installation

    Purchase the optional equipment lamps, etc.) in the air exist, may shutoff valve from your dealer. See Accesso- discolor walls or cause odors. ries, page 36. www.Astria.US.com 126882-01F...
  • Page 10: Fireplace Clearances

    " from the wall. This com- 2. If installing GA3450TA blower accessory, bustible material must be 4" from the side do so at this time. Follow instructions of the fireplace opening (see Figure 6). included with blower accessory. www.Astria.US.com 126882-01A...
  • Page 11 " Minimum Figure 7 - Rough Opening for Installing in Wall Nailing " Flanges " Nails or " Wood Screws " Figure 8 - Rough Opening for Installing Figure 9 - Attaching Fireplace to Wall in Corner Studs www.Astria.US.com 126882-01F...
  • Page 12 All measurements INSTALLING OPTIONAL BLOWER are in inches. ACCESSORY GA3450TA Refer to instructions provided with the blower for assembly instructions. Side of Firebox Figure 10 - Minimum Mantel Clearances for Built-In Installation www.Astria.US.com 126882-01A...
  • Page 13 Figure 13 - Gas Connection to allow proper gas volume to fire- * Purchase the optional equipment shutoff place. If pipe is too small, undue valve from your dealer. See Accessories, loss of volume will occur. page 36. www.Astria.US.com 126882-01F...
  • Page 14 Apply a noncorrosive leak detec- CAUTION: Avoid damage to tion fluid to all joints. Bubbles gas control. Hold gas control forming show a leak. Correct all with wrench when connecting leaks at once. it to gas piping and/or fittings (Remote-Ready Models Only). www.Astria.US.com 126882-01A...
  • Page 15: Connecting To Gas Supply

    3. Check all joints from gas meter to equip- ment shutoff valve for natural gas or Gas Meter Open Equipment Shutoff Valve Closed Figure 18 - Checking Gas Joints Figure 16 - Equipment Shutoff Valve (Natural Gas Only) www.Astria.US.com 126882-01F...
  • Page 16 Grasp sides of cover firmly and pull Slide to separate from base. Switch 5. Feed electrical wires through rectangular slots on each side of base (see Figure 22). REMOTE Frequency adjusting Figure 20 - Attaching Batteries to access hole Remote Receiver Receiver www.Astria.US.com 126882-01A...
  • Page 17 Figure 23 - Thermostat Base Terminals must not be lengthened. “W” and “R” 4. Connect one bare wire end to each of the terminals of the provided wall switch. 5. Install the wall switch and cover in the wall. www.Astria.US.com 126882-01F...
  • Page 18: Operation

    C. Use only your hand to push in or turn will only last a few hours. the gas control knob. Never use tools. If the knob will not push in or turn by 1. STOP! Read the safety information start- ing in column 1. www.Astria.US.com 126882-01A...
  • Page 19: Thermostat Control

    (de- pending on housing construction, installation location, room size, open air temperatures, etc.). Frequent use of your fireplace will let you determine your own comfort levels. Figure 26 - Natural Gas Pilot www.Astria.US.com 126882-01F...
  • Page 20 Force or attempted ON position after the pilot is lit. repair may result in a fire or explosion. www.Astria.US.com 126882-01A...
  • Page 21 3. Keep control knob pressed in for 30 sec- Figure 29 - Control Knob and Ignitor onds after lighting pilot. After 30 seconds, Button Location (Shown as Supplied - release control knob. Now follow steps 8 No Control Options) and 9 under Lighting Instructions. www.Astria.US.com 126882-01F...
  • Page 22 REMOTE or ON position when the pilot is not lit. This will drain the battery. Flame Control Adjustment Knob Knob Selector Switch in Remote Position (Optional Remote Control) Figure 32 - Setting the Selector Switch, Control Knob and Flame Adjustment Knob for Remote Operation www.Astria.US.com 126882-01A...
  • Page 23: Inspecting Burners

    19 for Thermostat-Controlled Models or page 21 for Remote-Ready Models) months during operation and have fireplace inspected yearly by a qualified service person. • see Troubleshooting, page 25 www.Astria.US.com 126882-01F...
  • Page 24: Wiring Diagram

    Use a soft cloth dampened with a mild soap Figure 37 - Injector Holder On Outlet and water mixture. Wipe the cabinet to re- Burner Tube move dust. WIRING DIAGRAM Blue (Remote-Ready Models Only) TPTH Gas Control TPTH TP Thermopile White www.Astria.US.com 126882-01A...
  • Page 25: Troubleshooting

    6. C l e a n O D S / p i l o t ( s e e Cleaning and Maintenance, page 23) or replace ODS/ pilot assembly 7. Gas regulator setting is not 7. Replace gas regulator correct www.Astria.US.com 126882-01F...
  • Page 26 Maintenance, page 23) or replace burner orifice 2. Damaged burner 2. Replace damaged burner 3. Gas regulator defective 3. Replace gas regulator 4. Inlet gas pressure is too low 4. Contact local natural or propane/LP gas company www.Astria.US.com 126882-01A...
  • Page 27 Fireplace produces a clicking/ 1. Metal expanding while 1. This is normal with most ticking noise just after burners heating or contracting while fireplaces. If noise is ex- are lit or shut off cooling cessive, contact qualified service person www.Astria.US.com 126882-01F...
  • Page 28 1. Foreign matter between 1. Take apart gas tubing and control valve and burner remove foreign matter 2. Gas leak. See Warning 2. Locate and correct all leaks statement at top of page (see Checking Gas Con- nections, page 14) www.Astria.US.com 126882-01A...
  • Page 29: Specifications

    • Inlet Gas Pressure (in. of water): • Inlet Gas Pressure (in. of water): Max - 14" W.C., Min* - 11" W.C. Max - 14" W.C., Min* - 11" W.C. Gamma26ZTN Gamma26ZMN • Rating (Variable): 17,000/26,000 Btu/Hr • Rating (Variable): 17,000/26,000 Btu/Hr •...
  • Page 30: Parts

    PARTS FIREBOX MODELS GAMMA26ZMP, GAMMA26ZMN, GAMMA26ZTN AND GAMMA26ZTP www.Astria.US.com 126882-01A...
  • Page 31 PARTS FIREBOX MODELS GAMMA26ZMP, GAMMA26ZMN, GAMMA26ZTN AND GAMMA26ZTP This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 29 of this manual. NO. PART NO. DESCRIPTION QTY. Outer Casing Top •...
  • Page 32 PARTS THERMOSTAT MODELS GAMMA26ZTP AND GAMMA26ZTN www.Astria.US.com 126882-01A...
  • Page 33 113342-01 Log Set • • PARTS AVAILABLE — NOT SHOWN 901056-01 Brass Flare Adapter Fitting • • 103470-01 Hardware Pack • • 100563-01 Warning Plate • • 101054-01 Lighting Instruction Plate • • ** Not a field replacement part www.Astria.US.com 126882-01F...
  • Page 34 PARTS REMOTE-READY MODELS GAMMA26ZMN AND GAMMA26ZMP Natural Gas Only www.Astria.US.com 126882-01A...
  • Page 35 099387-14 Pilot Tube • PARTS AVAILABLE — NOT SHOWN 901056-01 Brass Flare Adapter Fitting • • 103470-01 Hardware Pack • • 100563-01 Warning Plate • • 103877-01 Lighting Instruction Plate • • ** Not a field replacement part www.Astria.US.com 126882-01F...
  • Page 36: Accessories

    For all models. Optional extruded louver. Kit HEARTH BASE contains 2 louvers. W26GO - Medium Oak Finished, Georgian Design W26TO - Medium Oak Finished, Traditional Design W26TU - Unfinished, Traditional Design For all models. Complete assembly instruc- tions included. www.Astria.US.com 126882-01A...
  • Page 37 Wall- mount docking station included. RECEIVER AND HAND-HELD REMOTE CONTROL KIT - MRC For remote-ready models only. Allows the fireplace to be turned on and off by using a hand-held remote control. Wall-mount docking station included. www.Astria.US.com 126882-01F...
  • Page 38: Limited Lifetime Warranty

    THE WARRANTY Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria™ brand gas fireplace ("Product") to be free from defects in materials and workmanship at the time of manufacture. The Product body and firebox carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal breakage only.
  • Page 39 WARRANTY KEEP THIS WARRANTY Model (located on product or identification tag) _____________________________ Serial No. (located on product or identification tag) __________________________ Date Purchased __________________________ Keep receipt for warranty verification. www.Astria.US.com 126882-01F...
  • Page 40 1508 Elm Hill Pike, Suite 108 Nashville, TN 37210 126882-01 1-800-655-2008 Rev. A www.IHP.US.com 2/14 P126882-01...

This manual is also suitable for:

Gamma26ztpGamma26zmnGamma26zmp

Table of Contents