Advertisement

P/N 900285-01 REV. F 08/2016
Ce manuel est disponible en francais, simplement
en faire la demande. Numéro de la pièce 900285-03.
P900285-01
INSTALLER: Leave this manual with the appliance.
CONSUMER: Retain this manual for future
reference.
This appliance may be installed in an aftermarket permanently located, manufactured home (USA only)
or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas
indicated on the rating plate. This appliance is not convertible for use with other gases, unless a certifi ed kit
is used.
Cet appareil peut installé dans une maison préfabriquée (mobile) déjà installée à demeure, si les réglements
locaux le permettent. Ce appareil doit être utilisé uniquement avec le type de gaz indiqué sure la plaque
signalétique. Cet appareil ne peut être converti à d'autres gaz, sauf si une trousse de conversion est utilsée.
WARNING:
FIRE OR EXPLOSION HAZARD
Failure to follow safety warnings exactly could
result in serious injury, death, or property damage.
- Do not store or use gasoline or other fl ammable
vapors and liquids in the vicinity of this or any
other appliance.
- WHAT TO DO IF YOU SMELL GAS
• Do not try to light any appliance.
• Do not touch any electrical switch; do not use
any phone in your building.
• Leave the building immediately.
• Immediately call your gas supplier from a neigh-
bor's phone. Follow the gas supplier's instruc-
tions.
• If you cannot reach your gas supplier, call the
fi re department.
- Installation and service must be performed by
a qualifi ed installer, service agency or the gas
supplier.
Installation and Operation Instructions
Gemini™ Direct-Vent Gas Fireplaces
Models
Gemini33TMN
C
US
Gemini33TMP
Gemini33TEN
Report No. F13-094
Gemini33TEP
Installateur : Laissez cette notice avec l'appareil.
Consommateur : Conservez cette notice pour
consultation ultérieure.
Gemini35DMN
Gemini33RMN
Gemini35DMP
Gemini33RMP
Gemini35DEN
Gemini33REN
Gemini35DEP
Gemini33REP
GeminiCD35DEN
AVERTISSEMENT:
RISQUED'INDENDIE OU D'EXPLOSION
Le non-respect Des avertissements de sécurité
pourrait d'entraîner des blessures graves, la mort
ou des dommages matériels.
- Ne pas entreposer ni utilizer d'essence ni d'autres
vapeurs ou liquides infl ammables dans le voisinage
de cet appareil ou de tout autre appareil.
- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir
des téléphones se trouvant dans le bâtiment où
vous trouvez.
• Sortez immédiatement de bâtiment.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de gaz,
appelez le service des incindies.
- L'installation et l'entretien doivent être assurés par
un installateur ou un service d'entretien qualifi é
ou par le fournisseur de gaz.
Gemini40DMN
Gemini45DMN
Gemini40DMP
Gemini45DMP
Gemini40DEN
Gemini45DEN
Gemini40DEP
Gemini45DEP
GeminiCD40DEN

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Gemini33TMN and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Astria Gemini33TMN

  • Page 1 Installation and Operation Instructions Gemini™ Direct-Vent Gas Fireplaces P/N 900285-01 REV. F 08/2016 Models Gemini40DMN Gemini45DMN Gemini33TMN Gemini35DMN Gemini33RMN Ce manuel est disponible en francais, simplement en faire la demande. Numéro de la pièce 900285-03. Gemini35DMP Gemini40DMP Gemini45DMP Gemini33TMP Gemini33RMP...
  • Page 2: General Information

    Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 SAFETY AND YOUR FIREPLACE See attached color fl yer for proper color representation DANGER HOT GLASS WILL CAUSE BURNS. DO NOT TOUCH GLASS UNTIL COOLED. NEVER ALLOW CHILDREN TO TOUCH GLASS.
  • Page 3 Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 La sécurité et Safety and Your Seguridad y su votre foyer Fireplace chimenea All parts of your ¡Todas las partes de la Toutes les parties de votre IHP fi...
  • Page 4: Table Of Contents

    Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Traditional - Driftwood Logs Contemporary THANK YOU FOR YOUR PURCHASE. WE APPRECIATE YOUR BUSINESS! Please carefully read and follow all instructions in this manual. Pay special attention to all warnings and safety information.
  • Page 5: Important Safety Information

    Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 IMPORTANT SAFETY INFORMATION Important Safety Informa- L’information de sûreté Información importante de tion importante seguridad 1. WARNING: Do not operate appliance 1. AVERTISSEMENT. Ne pas utiliser l’appareil 1.
  • Page 6: Fireplace Installation, Operation, And Maintenance Notices

    Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 APPLIANCE INSTALLATION, SERVICE, AND MAINTENANCE NOTICES WARNING Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to this manual. For assistance or additional information consult a qualifi...
  • Page 7 Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 APPLIANCE OPERATION NOTICES These fi replaces are vented gas appliances. Do not burn wood or other material in these appliances. These appliances are designed to operate on natural gas or propane gas only. The use of other fuels or combinations of fuels will degrade the performance of this system and may be dangerous.
  • Page 8: Packaging List

    Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 INSTALLATION PACKAGING All models include The assembled vented gas fi replace heater is packaged with: • Literature Kit (envelope in bottom compartment containing Installation and Operation Instructions (this manual), Hot Glass Safety Flyer, and Safety-In-Operation Warning Labels) •...
  • Page 9: Gas Pressure

    Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 BTU Input Table 1 - Input Rate (BTU/HR), Gas Valves Natural Gas Propane Gas Models High Rate Low Rate High Rate Low Rate 33” Models 14,000 10,500 13,000 9,500...
  • Page 10: Requirements For The Commonwealth Of Massachusetts

    Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Orifi ce Sizes—Sea Level to High Altitude These fi replaces are tested and approved for installation at elevations of 0–4500 ft (0–1372 m) above sea level using the standard burner orifi...
  • Page 11: Manufactured Home Requirements

    Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 MANUFACTURED HOME REQUIREMENTS This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. Cet appareil peut être installé...
  • Page 12: Vent Termination Clearances

    Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 VENT TERMINATION CLEARANCES These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI Z223.1/NFPA 54) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 13 Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Table 7 - Horizontal vent termination clearances for buildings with combustible and noncumbustible exteriors Inside Corner Outside Corner Recessed Location See Table 6 Fixed Balcony with No Side Wall Balcony with Perpendicular Side Wall Openable Fixed Closed...
  • Page 14: Minimum Clearances To Combustibles

    Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 MINIMUM CLEARANCES TO COMBUSTIBLES Fireplace And Vent Clearances The fi replace is approved with zero clearance to combustible materials on all sides (Table 8), with the following exception: The unit may not be recessed (allowance made for mantel legs / side trim in (Figure 6).
  • Page 15: Wall Finishes / Surrounds / Mantels

    Innovative Hearth Products General Information Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Figure 6 - Combustible Side Clearances Figure 7 - Mantel Height At 6” minimum side wall Mantel depth Mantel depth At 6 in. minimum clearance, a 20 (508) side wall clearance, 25 (635)
  • Page 16: Installation

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 INSTALLATION SEQUENCE The typical sequence of installation is outlined below; however, each installation is unique and may result in variations to the steps described. See the pages referenced in the following steps for detailed instructions. Framing 1.
  • Page 17 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Table 10 - Fireplace Framing Specifi cations NOTE: Dimension “D” is the Framing required framing depth when 10-1/2 Model construction to be (267) the fi nish material (drywall) 2 x 4, or larger.
  • Page 18: Prepare The Fireplace Top Spacers

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Prepare the Fireplace Top Spacers 1. The two (2) 4” standoff spacers on top of the fi replace cabinet are shipped fl at. Remove the screw adjacent to the detached end (Figure 8).
  • Page 19 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Determining Vent Setup in the Combination Venting Unit Combination venting units are shipped with rear venting setup nearly ready for install. If this is the type of vent you require, remove all insulation packing and fl...
  • Page 20 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 5. Installing Non-Combustible Fireboard Standoff - All Models A non-combustible standoff board is provided for all model fi replaces to prevent overlap of drywall or other material of portions of the fi...
  • Page 21: Vent System Preparation

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Place the Fireplace in the Framing and Secure NOTE: Nailing fl anges, combustible members, and screw heads in areas directly adjacent to the nailing fl anges are EXEMPT from the 1/2”...
  • Page 22 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Install the Vent Restrictor (if necessary) 1. Use the vent run descriptions in Figure 12 to determine if a vent restrictor is necessary. 2. If necessary, assemble the vent restrictor and wing as detailed in Figures 12 and 15. 3.
  • Page 23 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Vent Restrictor with Horizontal Terminations When horizontally terminating a vent system with a vertical vent run up to 4 ft through an exterior wall, no vent restrictor is required. If installing more than 4 ft of vertical venting, install the restrictor (Figure 14), from inside or outside the unit, in the inner fi...
  • Page 24 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Vent section length table Table 14 will assist calculating how many vent sections are needed for the planned vent confi guration. When a vent section is engaged with another section, its effective length will be 1-1/2” shorter. Table 14 - Vent Section Length Nominal Section Nominal Section Length...
  • Page 25: Install The Vent System

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Clearance to combustibles Maintain the minimum clearance to combustibles (e.g., framing, attic, ceiling insulation, etc.). For all vertical runs: • 1” (26 mm) from all sides NOTE: Attic insulation shield (H3907, see Page 48) must be installed when blown or loose-fi ll insulation is used, and is required for all attic installations.
  • Page 26 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Vertical (Offset) Installation 1. Analyze the vent route and determine the number of vent sections and elbows required—See Effective Vent Length on Pages 23-24 for more information. Plan the venting so that a joint does not occur in the ceiling or roof joists.
  • Page 27 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 8. Continue installation of horizontal/inclined sections—Continue with the installation of the straight vent sections in horizontal/inclined run. Install support straps every 5 ft (1.52 m) along horizontal/inclined vent runs using conventional plumber’s tape.
  • Page 28 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Vertical Vent Figures/Tables NOTE: Secure Vent ® rigid vent pipe is shown in the fi gures; Secure Flex ® fl exible vent pipe may also be used. NOTE: Rise per foot run ratios are acceptable all the way to level.
  • Page 29 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Table 17 - Top Vent—Two 90° Elbows Table 18 - Rear Vent—Three Elbows Table 19 - Top Vent—Three Elbows When using Secure Flex ® , use ceiling fi restop/ spacer SF4.5VF.
  • Page 30 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Install the Horizontal Termination Vent System These instructions should be used as a guideline and do not supersede local codes in any way. Install venting according to local codes, these instructions, the current National Fuel Gas Code (ANSI-Z223.1) in the USA or the current standards of CAN/CGA-B149.1 in Canada.
  • Page 31 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 slightly elevated plane. The recommended incline is approximately 1/4” per 1 ft (20 mm per 1 m) horizontal, in a direction away from the fi replace. Smaller rise per foot run ratios are acceptable all the way to at or near level.
  • Page 32 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Installing the Horizontal Termination NOTE: To help minimize water infi ltration install the fi restop/spacer (SV4.5HF) on the exterior side of the wall. The fi restop may be caulked with mill base caulk (such as 10K81) or high-temperature silicone. Figure 27 - Venting Connection and Exterior Wall Recessing of the Horizontal Termination Maximum Wall Thickness * Use silicone caulking to seal the...
  • Page 33 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Table 20 - Venting Components Required for Various Exterior Wall Thicknesses, when using Typical Termination Kits Vent Components Required Exterior Wall Thickness Termination Kit Only 6 to 9-1/4” (152 to 235 mm) Termination Kit and 6”...
  • Page 34 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Table 23 - Top Vent—One 90° Elbow, Elbow Connection NOT at Fireplace H Maximum V Minimum feet meters feet meters 1.524 0.305 3.048 0.610 4.572 0.914 Ceiling fi...
  • Page 35 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Table 26 - Rear Vent—Three 90° Elbows H + H Maximum H Maximum V Minimum Wall fi restop/spacer Wall Firestop/Spacer feet meters feet meters feet meters SV4.5HF ** SV4.5HF** 1.524 0.610...
  • Page 36 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 ® Vertical or Horizontal Venting Using Secure Flex Kits and Components ® ® Secure Flex venting kits and components may be used in any other vent installation where rigid Secure Vent (SV4.5) direct-vent components can be used.
  • Page 37: Complete The Field Wiring

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 e. Slide the gear clamp down and tighten it fully to secure the fl exible vent to the adaptor outer collar approximately 3/4” from the end of the fl exible vent. f.
  • Page 38 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 NOTE: The supplied 15 ft of 2-conductor wire has one end of each conductor connected to the gas valve circuit and the other end of each conductor placed loose inside the bottom compartment. CAUTION In millivolt systems, do NOT connect a wall switch to a 120 V power supply.
  • Page 39: Install The [Optional] Blower Kit After Installation In The Framing

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 6. If a wall-mounted ON/OFF control, High/Low switch, or thermostat is to be used, mount it in a convenient location on a wall near the fi replace. 7.
  • Page 40: Connect The Gas Line

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Figure 32 - Junction Box Wiring, 120 V, 60 hz, 1 phase Figure 33 - Wiring Diagram—Millivolt Gas Valves Wall-mounted ON/ THERMOPILE OFF blower switch APPLIANCE- MOUNTED ON/OFF SWITCH or variable speed (OPTIONAL)
  • Page 41: Verify Proper Fireplace Operation

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Secure all joints tightly using appropriate tools and sealing compounds (ensure propane resistant compounds are used in propane applications). Optionally, seal around the gas line to prevent cold air leakage. Gas line holes and other openings can be caulked or stuffed with unfaced fi...
  • Page 42: Optional: Install The Firebox Liners

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Optional: Install the Firebox Liners 1. See Page 54 for instructions on Traditional Only: Installing the Firebox Liners. Install the Logs, Volcanic Stone, and Glowing Embers or Glass Media in Contemporary Fireplaces 1.
  • Page 43: Install The Hood

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Figure 38 - Air Shutter Adjustment Rod Table 28 - Air Shutter Adjustment Guidelines Adjustment Amount of Primary Flame Color Air Shutter Adjustment Set-Screw Adjustment If air shutter is Flame will Air shutter gap should be increased Rod Up...
  • Page 44: Install The Finishing Materials

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 NOTE: To install the hood after installing the non-combustible fi nish material over the black surface above the fi replace opening, the bottom edge of the fi nish material must be 5/8” above the top edge of the hood to allow clearance for installation and removal of the hood.
  • Page 45 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Installing Facade Step 1. Slide top trim pieces over fl ange of panel until seated squarely. Step 2. Slide side trim pieces into place (top will overlap slightly). Repeat Step 1 and Step 2 for bottom and opposite side trim for panel.
  • Page 46 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Installing Facade (continued) Step 4a. Slide the foot tabs of the facade base into the slots (see Step 4b. Tilting the facade base up on its foot tabs, secure the top by Figure 41) on both sides near the bottom of the fi...
  • Page 47 Juego de etiquetas de repuesto - Nº de cat. H8024 Cat. No. H8024 Replacement Label Kit Étiquettes de remplacement, n° cat. H8024 Astria.us.com Astria.us.com Astria.us.com Nota: La etiqueta en inglés es transparente con texto Remarque : Le texte anglais est rouge sur un support rojo.
  • Page 48: Installation Accessories

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 INSTALLATION ACCESSORIES ® Table 30 - Listed Secure Vent Components Cat. No. Model Description Cat. No. Model Description 77L78 SV4.5F Flat Roof Flashing Horizontal Square Termination 1/12 to 7/12 Adjustable 77L79 SV4.5FA H1968...
  • Page 49 Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Figure 30 - Listed Secure Vent ® Components Cat. No. Model Description Cat. No. Model Description Mill-Pac, Black, High- 10K81 SFMP Temperature Sealant 96K93 SV4.5SU Support Strap Mill-Pac, Black, High- 89L40 SFMP-12...
  • Page 50: Gas Conversion Kits

    Innovative Hearth Products Installation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 GAS CONVERSION KITS WARNING This conversion kit shall be installed by a qualifi ed service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fi...
  • Page 51: Operation

    Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 OPERATION WARNING Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house.
  • Page 52 Juego de etiquetas de repuesto - Nº de cat. H8024 proche pour recevoir IHP étiquettes d’instructions additional safety instruction labels free of charge. de sécurité supplémentaires gratuitement. Astria.us.com Cat. No. H8024 Replacement Label Kit Étiquettes de remplacement, n° cat. H8024 Nota: La etiqueta en inglés es transparente con texto Astria.us.com...
  • Page 53 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Burn-in Period The fi rst few times this fi replace is operated, there will be an odor from the curing of paint and the burning off of the lubricants used in the manufacturing process.
  • Page 54 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 If the millivolt fi replace is equipped with an optional remote switch (wall switch, remote control, rocker switch, or wall thermostat) and the pilot is lit, the fi replace main burner can be turned ON/OFF using the optional switch. NOTE: Do NOT wire more than one valve to the burner control switch.
  • Page 55 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Installing the volcanic stone, and glowing embers (traditional models) or glass media (contemporary models) WARNING • Turn OFF all gas and electricity to the appliance before installing the volcanic stone, embers, and logs. •...
  • Page 56 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Installing the 33” and 35” logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between fl ame peaks, so they do not impinge the fl...
  • Page 57 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Installing 40” and 45” logs The logs have notches/tabs to assist proper positioning. Upper logs rest on lower logs via notches/tabs. Proper log placement is critical to prevent sooting. Place the logs in the gaps between fl ame peaks, so they do not impinge the fl...
  • Page 58 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Installing and removing the glass door WARNING • Do not attempt to substitute the materials used on these doors, or replace cracked or broken glass. • Handle this glass with extreme care! Glass is susceptible to damage—Do not scratch or handle roughly while reinstalling the glass door frame.
  • Page 59 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Installing the glass door 1. Visually inspect the gasket on the backside of the glass door. NOTE: The gasket surface must be clean, free of irregularities, and seated fi rmly. Ensure it is properly located. Make sure the bead is not rolled into the channel at the top of the door, but remains fl...
  • Page 60: Maintenance

    Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 MAINTENANCE Refer to the Maintenance Schedule on Page 62 for maintenance tasks, procedures, frequency, and a listing of by whom the tasks should be performed. Always verify proper fi replace operation after servicing. WARNING Turn OFF gas and electrical power to the fi...
  • Page 61 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Inspecting the glass gasket Visually inspect the gasket on the backside of the glass door. The gasket surface must be clean, free of irregularities, and seated fi rmly. Cleaning the control compartment Keep the control compartment clean by vacuuming or brushing it out at least twice a year.
  • Page 62 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 MAINTENANCE SCHEDULE See the tables below for detailed information about required maintenance, both regular and annual. Table 40 - Maintenance Performed Annually—Before the Burning Season Maintenance Task Performed By Procedure Inspecting/Cleaning Burner, Logs...
  • Page 63: Accessory Components

    Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 ACCESSORY COMPONENTS Forced Air Kits The FBK-100 blower provides constant velocity forced air circulation. The FBK-200 assembly with variable speed, wall-mountable switch provides variable speed forced air circulation. The FBK-250 offers variable speed control and a heat-activated switch;...
  • Page 64 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 ACCESSORY COMPONENTS (continued) Facade Kits (Contemporary Models) Table 47 - Contemporary Facade Kits 35” Models 40” Models Panel Frame Base Description Catalog No. Model No. Catalog No. Model No.
  • Page 65 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 ACCESSORY COMPONENTS (continued) Ecofl ow Control Kits (Required Option for Ecofl ow Fireplaces) Ecofl ow Basic Remote Control Catalog Number • Manual ON/OFF operation F2687 • Off / Continuous pilot feature •...
  • Page 66 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 ACCESSORY COMPONENTS (continued) Variable Speed Wall Switch Kit The variable speed wall switch kit provides variable speed control if the optional FBK-100 blower kit is installed. Table 52 - Variable Speed Wall Switch Kit Catalog Model 045571H...
  • Page 67: Lighting Instructions

    Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 LIGHTING INSTRUCTIONS, MILLIVOLT - ENGLISH FOR YOUR SAFETY READ BEFORE LIGHTING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 68 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 LIGHTING INSTRUCTIONS, MILLIVOLT - FRENCH POUR PLUS DE SÉCURITÉ, LIRE AVANT D’ALLUMER AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 69 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 LIGHTING INSTRUCTIONS, ELECTRONIC SIT - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 70 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 LIGHTING INSTRUCTIONS, ELECTRONIC SIT - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 71 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 LIGHTING INSTRUCTIONS, ELECTRONIC ECOFLOW - ENGLISH FOR YOUR SAFETY READ BEFORE OPERATING WARNING: If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.
  • Page 72 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 LIGHTING INSTRUCTIONS, ELECTRONIC ECOFLOW - FRENCH POUR PLUS DE SÉCURITÉ LIRE AVANT DE METTRE EN MARCHE AVERTISSEMENT. Quiconque ne respecte pas à la lettre les instructions dans la présente notice risque de déclencher un incendie ou une explosion entraînant des dommages, des blessures ou la mort.
  • Page 73: Troubleshooting

    Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 TROUBLESHOOTING Before troubleshooting, ensure that the fi replace main line gas shutoff valve and the wall switch are in the ON position. The following troubleshoots the fi replace only to an elementary level. For detailed remote and ignition system troubleshooting, refer to the instructions provided with the remote.
  • Page 74 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Table 55 - Troubleshooting Electronic Systems SYMPTOM POSSIBLE CAUSES CORRECTIVE ACTION 1. Nothing happens a. Remote is not functioning properly. Check that the wall switch plate is set to REMOTE. when the fi...
  • Page 75: Replacement Parts

    Wall Switch Harness (Electronic) J7358 J7358 J7358 J7358 Vent Stopper Plug J7356 J7356 J7356 J7356 Burner Assembly F1654 F1646 J7354 J7354 Astria ® Diamond Grate J7399 J7399 J7400 J7400 Manning Glass Gasket F2116 F2116 F2116 F2116 Wall Plate J7401 J7401...
  • Page 76 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 REPLACEMENT PARTS (continued) 33” Models 35” Models 40” Models 45” Models Catalog Catalog Catalog Catalog Number Number Number Number ECOFLOW PARTS Pilot Assembly, Ecofl ow, Natural Gas J7935 J7935 J7935...
  • Page 77 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Figure 59 - Replacement Parts WARNING Failure to position the parts in accordance with these diagrams or failure to use only parts specifi cally approved with this appliance may result in property damage or personal injury. AVERTISSEMENT Risque de dommages ou de blessures si les pièces ne sont pas installées conformément à...
  • Page 78 Innovative Hearth Products Operation Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 NOTES...
  • Page 79: Warranty

    IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the IHP Warranty Department at 1508 Elm Hill Pike, Suite 108, Nashville, TN 37210 or visit our website at WWW.ASTRIA.US.COM.
  • Page 80 Innovative Hearth Products Installation and Operation Instructions Gemini™ and GeminiCD Series Direct-Vent Gas Fireplaces 900285-01 08/2016 Astria.us.com Record the following important information about your fi replace: Fireplace model number Fireplace serial number Date fi replace was Installed Type of gas fi replace uses...

Table of Contents