connection & installation
Communication Method Settings
Select a communication method for the camera.
#5
Communication Response Settings
Select a communication response method for the camera and controller: Response or No Response.
#6
Termination Settings
To prevent the attenuation of communication signals between the camera and controller, the items at
the end of line must be set up with the termination settings.
Camera Input Position
Terminal Resistance RX
Terminal Resistance TX
I
When terminating for RS-485: #8
When terminating for RS-422: #7, #8
Initialize
Initialize the system using the Initialize switch on the rear of the product.
Once initialized, all current settings will return to the factory default.
#10
I
If you do not set the Reset witch to OFF after resetting the system, all stored data will be lost when you restart the
system.
connection & installation
16_
Function
Transfer Mode Switch
Function
Response Mode Switch
#7
ON
OFF
ON
ON
Initialize
ON
ON
RS-422(4Wire)
RS-485(2Wire)
ON
Response
No Response
OFF
ON
Do not use initialization
OFF
OFF
OFF
#8