Section 3 - Installation; Siting The R5/4000; Connecting To Mains Supply; Setting Supply Voltage Tapping - NewArc R5000 CCCV Instruction Manual

Constant current / constant voltage power source
Hide thumbs Also See for R5000 CCCV:
Table of Contents

Advertisement

SECTION 3 — INSTALLATION
3.1 Siting the R4000/R5000
Site the R4000/R5000 on a clean dry sur-
face, preferable above ground level.
Make sure there is at least 20cm clearance
at the front, rear and right side of the ma-
chine to allow good circulation of the cool-
ing air.
Protect the machine from heavy rain and if
used in hot climates, against direct sunlight.
Ensure that the machine is positioned in
such a way that particles created by grind-
ing and cutting operations do not enter the
machine.
Note! Damage caused by metal particles and
water entering the machine will not be cov-
ered under warranty.

3.2 Connecting to mains supply

WARNING! All electric shocks are potentially
fatal, a competent electrician should carry
out the fitting of the mains plug.
Make sure that the mains supply is of the
correct voltage and current capability for
the machine.
Make sure that any extension cables used
are of sufficient current carrying capacity.
Make sure that the mains plug and socket
(if fitted) are in good condition and are of
the correct current carrying capacity. If the
machine is wired directly to the mains sup-
ply then an isolator switch must be fitted.
Note! See the technical specifications page for
correct supply information
Primary cable length
Long cable lengths may reduce the perform-
ance of the machine, the welding arc may
become unstable, especially at higher cur-
rents. Ensure the mains cable is not coiled up
during welding as this will reduce the input
voltage to the machine and may cause over-
heating and degradation of the cable.

3.3 Setting supply voltage tapping

WARNING! All electric shocks are potentially fa-
tal, a competent electrician should carry out any
supply voltage tapping adjustments required.
To enable the setting of the supply voltage
tapping, the front panel display cover of the
R4000/R5000 has to be removed.
The photograph below shows the voltage tap-
ping set to 415V, with the red wire from the
fuse holder connected to the 415 terminal.
This connector can be moved to the required
voltage terminal to select the desired input
voltage.
R5/4000 CCCV
6