Siena
ZSI-E30AS
ZSI-E36AS
ZSI-E30AS-ES
ZSI-E36AS-ES
Model number:
Serial Number:
SEP15.0301 © 2015 Zephyr Ventilation LLC.
www.zephyronline.com
ZSI-E30AS-ES
ZSI-E36AS-ES

Advertisement

loading

Summary of Contents for Zephyr ZSI-E30AS

  • Page 1 Siena ZSI-E30AS ZSI-E36AS ZSI-E30AS-ES ZSI-E36AS-ES ZSI-E30AS-ES ZSI-E36AS-ES Model number: Serial Number: SEP15.0301 © 2015 Zephyr Ventilation LLC.
  • Page 2 www.zephyronline.com...
  • Page 3: Table Of Contents

    SAFETY NOTICE ..............LIST OF MATERIALS ............INSTALLATION Ducting Calculation Sheet ........Mounting Height & Clearance ........ Ducting Options ......................Mounting the Range Hood ........Ductless Recirculating ..........FEATURES & CONTROLS ICON Touch Controls 11-12 ..........MAINTENANCE Cleaning and Filter Care ..........
  • Page 4 www.zephyronline.com READ AND SAVE THESE INSTRUCTIONS WARNING TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID-STATE CONTROL DEVICE. WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: a.
  • Page 5 15 or 20 ampere circuit breaker or time delay fuse. Wiring must be 2 wire with ground. Please also refer to Electrical Diagram on product. and install appropriate connector if necessary. ZSI-E30AS / ZSI-E36AS - 550 Watts, 5 Amps ZSI-E30AS-ES / ZSI-E36AS-ES - 136 Watts, 1.2 Amps...
  • Page 6: Installation

    2 - Baffle filters 1 - Duct cover assembly (top and bottom) 1 - Duct cover wall bracket 2 - 50W Halogen light bulbs (ZSI-E30AS & ZSI-E36AS) 2 - Fluorescent light bulbs (ZSI-E30AS-ES & ZSI-E36AS-ES) 1 - 8” round backdraft damper...
  • Page 7 Equivalent number Duct pieces Equivalent number Duct pieces length x used T otal length x used T otal 3- 1/ 4” x 10” 1 Ft. 3- 1/ 4” x 10” 5 Ft. Rect., Rect. to straight 6” round transition 6”, 7”, 8”, 10” 1 Ft.
  • Page 8 www.zephyronline.com ALWAYS, when possible, reduce the number of transitions and turns. If a long duct run is required, increase duct size from 8” to 10”. If turns or transitions are required: Install as far away from opening and as far apart, between 2, as possible.
  • Page 9: Ducting Options

    WARNING FIRE HAZARD NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Some Ducting Options Roof Pitch w/ Flashing &...
  • Page 10 www.zephyronline.com Front of Hood Side of Hood 10 1/2” 8 7/16” STANDARD min. ducted - 27 1/2” min. recirc. - 32” max. - 42” Z1C-00SI min. ducted - 46 1/2” min. recirc. - 50 1/2” max. - 79” 29 15/16”, 35 7/8” 21 15/16”...
  • Page 11 CAUTION: At least two installers are required due to the weight and size of the hood. 1. Measure from range top to hood bottom and mark line A. Duct Cover 2. Plum and mark center line. Bracket 9-7/16" 5. Mark mounting spread from C/L on line B 12-3/4” 6.
  • Page 12: Ductless Recirculating

    FOR MODELS ZSI-E30AS and ZSI-E36AS ONLY Ductless recirculating is intended for applications where an exhaust duct work is not possible to be installed. When converted, the hood functions as a recirculating hood rather than an exhaust hood. Fumes and exhaust circulated back within the home.
  • Page 13 Power / Delay Off Lights On/Dim/Off Adjust 5 Speed Levels Display (speed level, delay off, filter clean/change) 1 POWER / DELAY OFF BUTTON Power Button Function Button will turn power on and off for entire hood (fan and lights). - Hood will remember the last speed and light level it was turned off at. (Example: Press Button to turn off hood when on fan speed 4 and high lights.
  • Page 14 www.zephyronline.com 3 LIGHTS BUTTON - Lights are two levels, High and Low. - From off, press one time for High. Press again for Low. Press again to power lights off. 4 DISPLAY INDICATORS Mesh Filter Clean Reminder (always enabled) - After 30 hours of fan usage, the button indicator will begin to slowly blink indicating it is time to clean the mesh filters.
  • Page 15 SURFACE MAINTENANCE: Clean the hood surface periodically with hot soapy water and clean cotton cloth. Do not use corrosive or abrasive detergent, or steel wool/scouring pads which will scratch and damage surface. For heavier soil use liquid degreaser. After cleaning it is recommended that you use non-abrasive stainless steel polish/cleaners, to polish and buff out the stainless luster and grain.
  • Page 16: Light Bulbs

    DO NOT touch bulb until switched off and cooled. Touching hot bulbs could cause serious burns. Make sure all power is turned off and bulbs are not hot. ZSI-E30AS-ES & ZSI-E36AS-ES: Access light bulb by removing light bulb lens cover by 1 screw. FIG. B stops and falls out.
  • Page 17: Troubleshooting

    TROUBLESHOOTING PROCEDURES FOR SIENA WALL Issue Cause What to do After installation, 1. The power source is not turned ON. 1. Make sure the circuit breaker and the unit’s the unit doesn’t power is ON. work. 2. The power line and the cable locking connector 2.
  • Page 18 MAX. USE ONLY TYPE MR16, GU10, 50 W. HALOGEN LIGHT BULBS. Power consumption shown for default VOLTS MAX AMPS ZSI-E30AS, ZSI-E36AS ACT 290 CFM - Fan Max. 82W @ 0.74A CIRCUIT DIAGRAM REMARKS: CONDENSER 11+11uF 250V AC FIT AC120V 60Hz...
  • Page 19 ZSI-E30AS & ZSI-E36AS DESCRIPTION PART# Replacement Parts Optional Accessories Recirculating Kit ZRC-00SI Duct Cover Extension Kit Z1C-00SI Universal Make-Up Air Damper MUA008A ZSI-E30AS-ES & ZSI-E36AS-ES DESCRIPTION PART# Replacement Parts Optional Accessories Duct Cover Extension Kit Z1C-00SI To order parts, visit us online at http://store.zephyronline.com or call us at 1.888.880.8368...
  • Page 20: Warranty

    Zephyr Ventilation, LLC (referred to herein as “we” or “us”) warrants to the original consumer purchaser (referred to herein as “you” or “your”) of Zephyr products (the “Products”) that such Products will be free from defects in materials or workmanship as follows:...
  • Page 22: Product Registration

    PRODUCT REGISTRATION Congratulations on your Zephyr range hood purchase! Please take a moment to register your new range hood at www.zephyronline.com/registration IT’S IMPORTANT Prompt registration helps in more ways than one. Ensures warranty coverage should you need service. Ownership verification for insurance purposes.
  • Page 23 Siena ZSI-E30AS ZSI-E36AS ZSI-E30AS-ES ZSI-E36AS-ES ZSI-E30AS-ES ZSI-E36AS-ES Model number: Serial Number: SEP15.0301 © Zephyr Ventilation LLC.
  • Page 24 www.zephyronline.com...
  • Page 25 MISE EN GARDE DE SÉCURITÉ ..................LISTE DU MATÉRIEL ........................INSTALLATION Feuille de calcul pour le conduit................Espace libre et hauteur de montage................Options d’installation pour le conduit......................Montage de la hotte....................Recirculation d’air sans conduit................
  • Page 26 www.zephyronline.com LISEZ ET CONSERVEZ CES INSTRUCTIONS AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE OU DE DÉCHARGE ÉLECTRIQUE, N’UTILISEZ PAS CET APPAREIL AVEC UN TABLEAU DE COMMANDE À SEMI-CONDUCTEURS. AVERTISSEMENT POUR RÉDUIRE LES RISQUES D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE, RESPECTEZ CES CONSIGNES : a.
  • Page 27 Un raccord de câble (non inclus) pourrait également être exigé par les normes et réglementations locales. Informez-vous des exigences et des normes locales. Achetez et installez le connecteur approprié si nécessaire. ZSI-E30AS / ZSI-E36AS - 550 Watts, 5 Amps ZSI-E30AS-ES / ZSI-E36AS-ES - 136 Watts, 1.2 Amps...
  • Page 28 1 - Ensemble de recouvrement de conduit (parties supérieure et inférieure) 1 - Support mural pour le recouvrement de conduit 2 - Ampoules halogens 50W (ZSI-E30AS & ZSI-E36AS) 2 - Ampoules fluorescentes 13W (ZSI-E30AS-ES & ZSI-E36AS-ES) 1 - Registre antirefoulement circulaire de 8"...
  • Page 29 Longueur x Longueur x Pièces de conduit Pièces de conduit T otal T otal Nombre utilisé Nombre utilisé 3- 1/ 4” x 10” 1 pi 6” circ. à 5 pi rect., droit rect. de 3-1/4" x 10" 6”, 7”, 8”, 10” 1 pi 6”...
  • Page 30 www.zephyronline.com Lorsqu’il possible de le faire, diminuez TOUJOURS le nombre de pièces et de changements de direction. Si un long tronçon de conduit est nécessaire, augmentez le diamètre du conduit de 8” à 10”. Si des changements de direction ou des adaptateurs sont nécessaires, installez-les le plus loin possible de x .
  • Page 31 N’évacuez ou ne terminez JAMAIS l’échappement du conduit dans les espaces entre les murs, les vides sanitaires, le plafond, le grenier, ou le garage. Tous les échappements doivent être dirigés à l’extérieur de la maison, à moins que l’option de recirculation d’air ne soit utilisée. N’utilisez que des conduits en métal pour cloison simple.
  • Page 32 www.zephyronline.com Devant de la hotte Côté de la hotte 10 1/2” 8 7/16” STANDARD min. avec conduit - 27 1/2” min. avec recirc. d’air - 32” max. - 42” Z1C-00SI min. avec conduit - 46 1/2” min. avec recirc. d’air - 50 1/2” max.
  • Page 33 ATTENTION : Compte tenu du poids et des dimensions de la hotte, au moins deux installateurs sont nécessaires. 1. Prenez la mesure entre la surface de la cuisinière et la base de la hotte; marquez la ligne A (min. 26” à partir du dessus de la cuisinière). 2.
  • Page 34 Lorsque transformée, la hotte fonctionne comme une hotte de recirculation d’air plutôt que comme un Nous recommandons de TOUJOURS évacuer l’air à l’extérieur de la maison en utilisant le conduit en place ou, s’il y conduit d’aération. ZSI-E30AS ZRC-00SI ZSI-E36AS ZRC-00SI recouvrement de conduit (FIG.B).
  • Page 35 Choix de 5 vitesses Lumières : Mise en marche/Arrêt à retardement Allumer/Veilleuse/Éteindre Afficheur (vitesse, arrêt à retardement, nettoyage/changement des filtres) 1 MISE EN MARCHE/ARRÊT À RETARDEMENT Fonction de la touche de mise en marche - La touche permet d’allumer et d’éteindre toutes les fonctions de la hotte (ventilateurs et lumières). - La hotte se rappelle la dernière vitesse et le dernier niveau d’éclairage utilisés.
  • Page 36 www.zephyronline.com 3 TOUCHE DE CONTRÔLE DES LUMIÈRES - Il existe deux intensités : haute et basse. - Lorsque les lumières sont éteintes, appuyez une fois pour les allumer à haute intensité. Appuyez de nouveau pour les mettre en veilleuse. Appuyez encore une fois pour les éteindre. 4 AFFICHEUR Rappel de nettoyage des filtres à...
  • Page 37 ENTRETIEN DES SURFACES Nettoyez régulièrement les surfaces de la hotte avec de l’eau savonneuse chaude et un chiffon de coton propre. N’utilisez pas de détergent abrasif ou corrosif, de laines d’acier ou de tampons à récurer; ils égratigneront et endommageront les surfaces. Pour les taches plus tenaces, utilisez du produit dégraissant liquide.
  • Page 38 Les ampoules de remplacement sont disponibles dans les magasins spécialisés en éclairage. ZSI-E30AS & ZSI-E36AS: Procurez-vous des ampoules halogènes GU-10 50W. ZSI-E30AS-ES & ZSI-E3AS-ES: Procurez-vous des ampoules Flourescent GU-24, STS T3 13GUS Consultez la page 17 du présent guide pour obtenir les numéros de pièces Zephyr.
  • Page 39 Cause Après l’installation, 1. Le bloc d’alimentation n’est pas allumé 1. Assurez-vous que l’alimentation du disjoncteur et de l’appareil ne l’appareil est allumée fonctionne pas. 2. La ligne électrique et le raccord de câble ne sont pas correctement branchés correctement 3.
  • Page 40 Consommation énergétique avec UTILISEZ SEULEMENT DES AMPOULES HALOGÈNES MR16, GU10, 35W ventilateur de 650 pi /min. VOLTS A. MAX. ZSI-E30AS, ZSI-E36AS ACT 390 pi3/min - Max. du ventilateur : 393W à 3,3 A SCHÉMA DE CIRCUITS ROUGE BLANC ACT 290 pi3/min - Max. du ventilateur BLANC : 365W à...
  • Page 41 ZSI-E30AS & ZSI-E3AS DESCRIPTION Nº DE PIÈCE Ampoule halogène de 50W (unité) Z0B-0020 Trousse de recirculation d’air ZRC-00SI Filtre à charbon de remplacement (unité) Z0F-C091 Trousse de prolongement de recouvrement de conduit Z1C-00SI ZSI-E30AS-ES & ZSI-E36AS-ES DESCRIPTION Nº DE PIÈCE...
  • Page 42 Zephyr Ventilation, LLC (désigné aux présentes sous le nom de « nous ») garantit au premier acheteur (désigné aux présentes sous le nom de « vous » ou « votre ») de produits Zephyr (les « Produits ») que lesdits produits sont exempts de défauts de fabrication ou de main-d’œuvre selon les conditions suivantes :...
  • Page 44 À des fins d’assurance, il permet de confirmer que vous êtes le propriétaire. Il vous permet de recevoir des avis concernant des modifications ou des rappels de produits. Zephyr Ventilation | 2277 Harbor Bay Pkwy. | Alameda, CA 94502 | 1.888.880.8368...

This manual is also suitable for:

Zsi-e36as-esZsi-e36asZsi-e30as-es